{"product_id":"schneider-electric-xpsuaf13ap-harmony-xps-universal-safety-relay-cat-4-24v-ac-dc-3no-outputs","title":"Schneider Electric XPSUAF13AP Harmony XPS Universal Safety Relay Cat 4 24V AC\/DC 3NO Outputs","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Schneider Electric XPSUAF13AP is a Harmony XPSU series safety relay designed for Category 4 safety applications. Operating on 24 V AC\/DC, it provides monitoring capability for a wide range of safety devices through two safety inputs and three NO safety outputs. The module features removable screw terminals and configurable pulsed outputs for straightforward installation and integration into safety systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 607.407px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003eSafety Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003eXPSUAF13AP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003eSafety Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Supply Voltage [Us]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e24 V AC\/DC (–15…+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eStart Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003eAutomatic \/ Manual \/ Monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e2 W (24 VDC), 5 VA (24 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e2 × 24 VDC, 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e3 × NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e3 × configurable pulsed outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eDiagnostic Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003eSemiconductor 24 VDC, 20 mA (Z1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 39.1875px;\"\u003e\u003cstrong\u003eConventional Thermal Current [Ith]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 39.1875px;\"\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e10 A gG (IEC 60947-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 39.1875px;\"\u003e\u003cstrong\u003eMinimum Output Current \/ Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 39.1875px;\"\u003e10 mA \/ 15 V (relay output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Response Time (Input Open)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 39.1875px;\"\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Insulation Voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e250 V (pollution degree 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 39.1875px;\"\u003e\u003cstrong\u003eImpulse Withstand Voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 39.1875px;\"\u003e4 kV (category II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Wire Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003eElectronic (internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmbient Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e–25…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e5…95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e22.5 × 120 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003ePLe \/ Category 4, SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 39.1875px;\"\u003e\u003cstrong\u003eApplicable Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 39.1875px;\"\u003eIEC 60947-5-1, IEC 61508-1\/2\/3, ISO 13849-1, IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0324%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7484%; height: 19.5938px;\"\u003e2.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About XPSUAF13AP\u003c\/h4\u003e\n\u003cp class=\"\"\u003eThe XPSUAF13AP belongs to the Harmony XPSU family, offering universal safety monitoring for devices such as E-Stops, guard switches, magnetic sensors, light curtains, RFID safety switches, and PNP safety sensors. Its internal architecture provides selectable safety functions using rotary switches, enabling flexible adaptation to different machine safety requirements. Designed for PLe\/Category 4 and SIL 3 applications, the relay incorporates semiconductor diagnostic output, configurable pulsed outputs, and robust protective features. Common usage includes packaging machinery, material handling equipment, hoisting systems, and food and beverage production where reliable high-level safety monitoring is essential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCategory 4 \/ PLe safety rating: Meets ISO 13849-1, IEC 62061, and IEC 61508 standards.\u003c\/li\u003e\n\u003cli\u003e24 V AC\/DC operation: Supports universal low-voltage safety circuit requirements.\u003c\/li\u003e\n\u003cli\u003eTwo safety inputs: Suitable for E-Stops, interlocks, light curtains, and similar devices.\u003c\/li\u003e\n\u003cli\u003eThree NO safety outputs: Provides redundant relay signaling for safety-actuated shutdown.\u003c\/li\u003e\n\u003cli\u003eConfigurable pulsed control outputs: Three on\/off diagnostic-capable outputs for input monitoring.\u003c\/li\u003e\n\u003cli\u003eRotary selector configuration: Enables predefined and selectable safety functions.\u003c\/li\u003e\n\u003cli\u003eRemovable screw terminal blocks: Simplify wiring and replacement during maintenance.\u003c\/li\u003e\n\u003cli\u003eBroad environmental tolerance: Designed for industrial environments with high reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XPSUAF13AP delivers the reliability and precision required for machine safety systems across demanding industrial applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47572922597674,"sku":"XPSUAF13AP","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/XPSUAF13AP_front_1500x1500_aeb3ba6e-e497-4d30-8ce3-fc3878c1f4c4.jpg?v=1708604961","url":"https:\/\/iqelectro.com\/products\/schneider-electric-xpsuaf13ap-harmony-xps-universal-safety-relay-cat-4-24v-ac-dc-3no-outputs","provider":"IQElectro","version":"1.0","type":"link"}