{"product_id":"sick-rly3-emss100-rely-safety-relay","title":"Sick RLY3-EMSS100 ReLy Safety Relay","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Sick RLY3-EMSS100 is a ReLy safety relay designed to monitor safety sensors with potential-free outputs and control safety-related functions in industrial machinery. It provides two safety inputs, two safe enabling current paths, and integrated monitoring functions to support reliable machine shutdown when a safety condition is detected.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 368px; max-width: 100%; font-size: 14px; height: 703px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003eSick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003eIndustrial Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003eRLY3-EMSS100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003eReLy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003eSafety Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003eSafety Relay \/ Evaluation Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eSafety Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.9375px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 90.0938px;\"\u003e\u003cstrong\u003eReset \/ EDM Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 251.906px;\"\u003e1 input for reset pushbutton or external device monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eSafe Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003e2 enabling current paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.9375px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 90.0938px;\"\u003e\u003cstrong\u003eDiagnostic Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 251.906px;\"\u003e2 application diagnostic outputs, not safety-rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.9375px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 90.0938px;\"\u003e\u003cstrong\u003eTest Pulse Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 251.906px;\"\u003e3, not safety-rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.9375px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 90.0938px;\"\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 251.906px;\"\u003eSIL 3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 90.0938px;\"\u003e\u003cstrong\u003eSafety Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 251.906px;\"\u003eCategory 4 (ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.9375px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 90.0938px;\"\u003e\u003cstrong\u003ePerformance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 251.906px;\"\u003ePL e (ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1667px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 90.0938px;\"\u003e\u003cstrong\u003eReset Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1667px; width: 251.906px;\"\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 90.0938px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 251.906px;\"\u003eFront connector with spring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.9375px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 90.0938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 41.9375px; width: 251.906px;\"\u003e−25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1875px; width: 90.0938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 21.1875px; width: 251.906px;\"\u003e130 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About RLY3-EMSS100\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe RLY3-EMSS100 belongs to the Sick ReLy safety relay series and functions as an evaluation unit for compatible safety sensors. It monitors input signals for discrepancies and cross-circuit faults, and supports restart interlocking and external device monitoring (EDM). The relay offers automatic or manual reset options and is designed for safety applications requiring up to SIL 3 and Performance Level e, subject to correct system design and installation. Its compact 18 mm housing and spring-terminal connections make it suitable for DIN-rail installation in industrial control cabinets.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Relay Function: Evaluates signals from compatible safety sensors with potential-free outputs.\u003c\/li\u003e\n\u003cli\u003eTwo Safety Inputs: Supports dual-channel safety input monitoring.\u003c\/li\u003e\n\u003cli\u003eSafe Enabling Outputs: Provides two safety-related enabling current paths.\u003c\/li\u003e\n\u003cli\u003eFault Monitoring: Includes discrepancy monitoring and cross-circuit detection.\u003c\/li\u003e\n\u003cli\u003eExternal Device Monitoring: Includes EDM functionality for monitoring external switching devices.\u003c\/li\u003e\n\u003cli\u003eHigh Safety Ratings: Supports SIL 3, Category 4, and PL e when used in a compliant safety system.\u003c\/li\u003e\n\u003cli\u003eCompact Installation: Features an 18 mm-wide housing and spring-terminal connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Sick RLY3-EMSS100 provides safety signal evaluation and monitored shutdown functions for industrial machinery and automation systems.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Sick","offers":[{"title":"Default Title","offer_id":52927310135594,"sku":"RLY3-EMSS100","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/OIP_153c2c49-f8bc-4033-adf4-46f925b94eb7.webp?v=1791891379","url":"https:\/\/iqelectro.com\/products\/sick-rly3-emss100-rely-safety-relay","provider":"IQElectro","version":"1.0","type":"link"}