{"product_id":"siemens-3va4140-5ed34-0aa0-sentron-3va4-molded-case-circuit-breaker","title":"Siemens 3VA4140-5ED34-0AA0 SENTRON 3VA4 Molded Case Circuit Breaker","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Siemens 3VA4140-5ED34-0AA0 is a SENTRON 3VA4 molded case circuit breaker designed for line protection in low-voltage electrical distribution systems. It is a three-pole, 40 ampere breaker equipped with a TM210 thermal-magnetic trip unit and provides a 35 kiloampere interrupting rating at 480 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.975%; height: 392.014px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e3VA4140-5ED34-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eSENTRON 3VA4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e3VA41 UL Frame 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eMaximum Frame Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eTM210 Thermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eProtection Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eOverload Protection Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e40 A, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eInstantaneous Short-Circuit Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e10 × Rated Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Capacity at 480 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e35 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Capacity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eLug \/ Terminal Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eManufacturer Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003eActive Product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 54.8015%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6119%; height: 19.6007px;\"\u003e2.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About 3VA4140-5ED34-0AA0\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe 3VA4140-5ED34-0AA0 is a Siemens SENTRON 3VA4 molded case circuit breaker built on the UL Frame 125 platform for system and line protection. It incorporates a TM210 fixed thermal-magnetic trip unit with a 40 ampere permanently set overload threshold and instantaneous short-circuit protection set at ten times the rated current. The three-pole breaker uses terminal connections and is suitable for integration into compatible low-voltage distribution equipment, switchboards, and panelboard systems. Its M interrupting capacity class provides 35 kiloamperes at 480 volts, while Siemens identifies this exact catalog number as an active product.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eThree-Pole Configuration: Provides simultaneous circuit protection across three poles for low-voltage distribution applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e40 Ampere Rating: Rated continuous operational current is 40 amperes. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eTM210 Trip Unit: Uses a fixed thermal-magnetic overcurrent release with long-time and instantaneous protection functions. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eFixed Overload Protection: The thermal overload setting is permanently configured at 40 amperes. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInstantaneous Protection: Short-circuit protection is permanently set at ten times the rated current. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eM Interrupting Class: Provides an interrupting rating of 35 kiloamperes at 480 volts. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eFrame 125 Construction: Uses the SENTRON 3VA41 frame with a maximum frame current rating of 125 amperes. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eUL 489 Applications: Siemens specifies this model for Heating, Air Conditioning, and Refrigeration and High-Intensity-Discharge circuit breaker applications under UL 489. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 3VA4140-5ED34-0AA0 delivers the reliability and precision required for low-voltage circuit protection in industrial and commercial electrical distribution systems.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695542268202,"sku":"3VA4140-5ED34-0AA0","price":432.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1200_abed7eff-33a2-42d0-8eb2-2ab598c4c7d0.jpg?v=1789930418","url":"https:\/\/iqelectro.com\/products\/siemens-3va4140-5ed34-0aa0-sentron-3va4-molded-case-circuit-breaker","provider":"IQElectro","version":"1.0","type":"link"}