{"product_id":"siemens-3va5150-6ed31-0aa0-3va5-series-50a-3-pole-thermal-magnetic-circuit-breaker","title":"Siemens 3VA5150-6ED31-0AA0 3VA5 Series 50A 3-Pole Thermal-Magnetic Circuit Breaker","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Siemens 3VA5150-6ED31-0AA0 is a high-performance molded case circuit breaker designed to provide dependable overcurrent and short-circuit protection in commercial and industrial electrical panels. This 50-amp, three-pole device utilizes a proven thermal-magnetic trip mechanism to continuously monitor loads and disconnect power safely during fault conditions. By securing critical branch circuits against unexpected electrical surges, this component prevents downstream machinery damage and stabilizes overall facility power distribution.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCondition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSiemens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3VA5150-6ED31-0AA0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSubcategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCircuit Breakers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eAmperage Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMaximum Voltage Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eNumber of Poles\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eFrame Size\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 A Frame\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eTrip Unit Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermal-Magnetic (TM210)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eProtection Parameters\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed Thermal, Fixed Magnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInterrupting Capacity Class\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh (Class H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePhase Connection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase (ABC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCertifications\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL 489, CSA C22.2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e3VA5150-6ED31-0AA0\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 3VA5150-6ED31-0AA0 is an integral part of the versatile 3VA5 series, engineered within a compact 125-amp frame to optimize spatial efficiency in crowded control panels. It features a reliable TM210 thermal-magnetic trip unit that delivers fixed thermal and fixed magnetic protection, ensuring consistent fault response without requiring complex calibration. Electrical engineers deploy this UL 489 rated breaker to safeguard low-voltage industrial infrastructure that demands robust interrupting capabilities up to 480 VAC. The housing is constructed from high-dielectric thermoset materials that safely contain internal arc flashes, allowing for secure integration into demanding manufacturing environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e● Thermal-Magnetic Trip Unit: Employs a robust TM210 sensing mechanism to provide consistent, reliable protection against sustained overloads and sudden short circuits.\u003cbr\u003e● High Interrupting Capacity: Delivers exceptional fault clearing performance at standard industrial voltages to safely isolate severe electrical anomalies.\u003cbr\u003e● Compact Frame Size: Utilizes a space-saving 125-amp physical footprint to allow for greater component density within modern switchboards and control panels.\u003cbr\u003e● Three-Pole Configuration: Engineered specifically to regulate and protect three-phase alternating current power within commercial electrical networks.\u003cbr\u003e● Fixed Trip Settings: Features predetermined thermal and magnetic trip thresholds to simplify installation and prevent accidental field miscalibration.\u003cbr\u003e● Arc Isolation Chambers: Incorporates specialized internal arc chutes to extinguish electrical arcing rapidly and prevent phase-to-phase flashovers during a trip event.\u003cbr\u003e● Modular Architecture: Supports seamless integration with an extensive range of internal accessories, including auxiliary switches and shunt trips.\u003cbr\u003eThe 3VA5150-6ED31-0AA0 delivers the reliability and precision required for secure power distribution and effective fault prevention in industrial switchgear.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52611848372522,"sku":"3VA5150-6ED31-0AA0","price":705.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_37b3a2a2-2e24-435d-8c65-9c6d54e71ddf.webp?v=1789476088","url":"https:\/\/iqelectro.com\/products\/siemens-3va5150-6ed31-0aa0-3va5-series-50a-3-pole-thermal-magnetic-circuit-breaker","provider":"IQElectro","version":"1.0","type":"link"}