{"product_id":"siemens-500-034850-cerberus-pyrotronics-mxl-fire-alarm-control-module","title":"Siemens 500-034850 Cerberus Pyrotronics MXL Fire Alarm Control Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eSiemens 500-034850 is a fire alarm control system component designed for use within compatible Cerberus Pyrotronics MXL fire detection systems. It provides system interface and control functionality for legacy MXL installations and is intended for replacement and maintenance applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.941%; height: 372.282px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003e500-034850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eFire Alarm Zone Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eConventional Zone Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eHZM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eFire Alarm System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eFireFinder XLS, Siemens Modular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eInitiating Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003e1 conventional zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eUp to 15 compatible Siemens two-wire detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eClass A \/ Style D or Class B \/ Style B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Zone Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003e35 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupervisory Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003e18–24.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Zone Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003e34 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003e24 VDC Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003e18.8–28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum 24 VDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003eSiemens DPU Program\/Test Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.9772%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6039%; height: 19.5938px;\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e1.21 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e500-034850\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 500-034850 is identified as a Siemens Cerberus Pyrotronics component associated with the MXL fire alarm platform. It is intended to operate as part of the modular MXL control architecture and interfaces with compatible system electronics. The component is used in existing fire detection installations where maintaining compatibility with the original MXL equipment is required. Its legacy design makes accurate part-number matching important when selecting a replacement component.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMXL System Compatibility: Designed for use within compatible Siemens Cerberus Pyrotronics MXL fire alarm systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLegacy System Support: Provides replacement capability for existing MXL installations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModular Architecture: Integrates into the modular construction of compatible MXL control equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFire Alarm Application: Intended for use as part of a fire detection and alarm control system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOEM Identification: Uses Siemens part number 500-034850 for equipment identification.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance Replacement: Suitable for service and replacement requirements on compatible systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSystem Integration: Designed to interface with other compatible MXL system components.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial Construction: Built for integration into dedicated fire alarm control equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe 500-034850 provides compatible system functionality for maintenance and replacement applications within Siemens MXL fire alarm installations.\u003c\/span\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52567599677738,"sku":"500-034850","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/main_1.jpg?v=1789107091","url":"https:\/\/iqelectro.com\/products\/siemens-500-034850-cerberus-pyrotronics-mxl-fire-alarm-control-module","provider":"IQElectro","version":"1.0","type":"link"}