{"product_id":"siemens-cerberus-pyrotronics-tri-60r-addressable-relay-interface-module","title":"Siemens Cerberus Pyrotronics TRI-60R Addressable Relay Interface Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens TRI-60R is an addressable relay interface module designed to connect dry-contact and shorting devices to compatible Siemens Cerberus Pyrotronics fire alarm systems. Engineered for dependable monitoring and control, the module provides seamless integration with XL3 and MXL addressable systems while maintaining reliable life safety communication.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Cerberus Pyrotronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTRI-60R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Relay Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTRI-60 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay and dry-contact interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Cerberus Pyrotronics XL3, MXL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eINX Addressable Module, IXL ICON-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMXL ALD addressable loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous monitoring of connected devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm monitoring and control interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal panel or field enclosure mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor commercial installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial electronic interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.4 lb (0.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e TRI-60R\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe TRI-60R is part of the Siemens Cerberus Pyrotronics TRI-60 series of addressable interface modules, developed to expand the functionality of intelligent fire alarm systems by interfacing external contact devices. It communicates with compatible XL3 systems through INX addressable modules or IXL ICON-1 interfaces and connects directly to MXL ALD loop circuits for distributed monitoring and control applications. The module supervises connected field devices while providing addressable identification, allowing the fire alarm control panel to accurately identify device status and alarm conditions. Its compact industrial design makes it suitable for commercial buildings, healthcare facilities, educational campuses, manufacturing plants, and other installations requiring dependable addressable relay interfacing.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAddressable Relay Interface: Integrates external relay and contact devices into Siemens fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eShorting Device Interface: Designed to monitor and interface dry-contact devices.\u003c\/li\u003e\n\u003cli\u003eXL3 Compatibility: Supports Siemens Cerberus Pyrotronics XL3 systems.\u003c\/li\u003e\n\u003cli\u003eMXL Compatibility: Connects directly to Siemens MXL ALD addressable loop circuits.\u003c\/li\u003e\n\u003cli\u003eINX Module Support: Interfaces with compatible INX addressable modules.\u003c\/li\u003e\n\u003cli\u003eIXL ICON-1 Compatibility: Supports operation with Siemens IXL ICON-1 interfaces.\u003c\/li\u003e\n\u003cli\u003eAddressable Identification: Reports individual device status to the control panel.\u003c\/li\u003e\n\u003cli\u003eContinuous Supervision: Monitors connected circuits for reliable operation.\u003c\/li\u003e\n\u003cli\u003eCompact Module Design: Simplifies installation within compatible fire alarm enclosures.\u003c\/li\u003e\n\u003cli\u003eCommercial Reliability: Engineered for continuous life safety operation.\u003c\/li\u003e\n\u003cli\u003eOEM Siemens Construction: Manufactured for seamless compatibility with Cerberus Pyrotronics systems.\u003c\/li\u003e\n\u003cli\u003eFlexible Integration: Supports a variety of initiating and control applications within addressable fire alarm networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TRI-60R delivers the reliability and precision required for addressable relay interfacing in commercial fire alarm and life safety systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52141759168810,"sku":"TRI-60R","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_8453f187-a438-4db8-a9d0-83ebedf6cf34.webp?v=1785271977","url":"https:\/\/iqelectro.com\/products\/siemens-cerberus-pyrotronics-tri-60r-addressable-relay-interface-module","provider":"IQElectro","version":"1.0","type":"link"}