{"product_id":"siemens-cmi-300-cxl-mxl-fire-alarm-communication-interface-module","title":"Siemens CMI-300 CXL\/MXL Fire Alarm Communication Interface Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens CMI-300 is a communication interface module designed to provide modem-based communication between Siemens MXL fire alarm systems and CXL or NCCNT WAN graphics systems. Installed on the MOM-4 motherboard, the module translates MXL communication signals into CXL modem signals, enabling reliable remote monitoring and system integration.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMI-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Communication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCXL\/MXL Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModem communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Fire Alarm System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens MXL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHost Board\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOM-4 motherboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Communication Boards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMMB-1, MMB-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCXM-1 module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNCCNT WAN Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHUB-4 module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModem-based serial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf-slot module for MOM-4 board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm network communication and remote monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor commercial installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial electronic communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.5 lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e CMI-300\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe CMI-300 is part of the Siemens MXL fire alarm communication platform, developed to extend network connectivity between legacy MXL control panels and centralized monitoring or graphics management systems. Installed in a half-slot position on the MOM-4 board, the module interfaces with MMB-1 or MMB-2 communication lines and converts system data for transmission over modem communication links. It supports integration with CXL systems through the CXM-1 interface module and with NCCNT WAN networks through the HUB-4 communication module, allowing centralized supervision of distributed fire alarm installations. Designed for commercial and institutional life safety systems, the CMI-300 provides dependable communication for remote system monitoring, diagnostics, and event reporting.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMXL Communication Interface: Connects Siemens MXL fire alarm systems to external communication networks.\u003c\/li\u003e\n\u003cli\u003eSignal Translation: Converts MXL communication into CXL modem communication signals.\u003c\/li\u003e\n\u003cli\u003eMOM-4 Installation: Installs directly into a half-slot on the Siemens MOM-4 motherboard.\u003c\/li\u003e\n\u003cli\u003eMMB Compatibility: Interfaces with MMB-1 and MMB-2 communication lines.\u003c\/li\u003e\n\u003cli\u003eCXL System Support: Enables communication with Siemens CXL systems through the CXM-1 module.\u003c\/li\u003e\n\u003cli\u003eNCCNT WAN Integration: Supports centralized graphics systems using the HUB-4 interface.\u003c\/li\u003e\n\u003cli\u003eRemote System Monitoring: Provides reliable communication for off-site supervision and diagnostics.\u003c\/li\u003e\n\u003cli\u003eOEM Siemens Module: Designed for seamless integration with Siemens fire alarm architecture.\u003c\/li\u003e\n\u003cli\u003eModular Design: Simplifies installation, maintenance, and future system expansion.\u003c\/li\u003e\n\u003cli\u003eCommercial Life Safety Application: Suitable for large distributed fire alarm installations.\u003c\/li\u003e\n\u003cli\u003eReliable Data Transmission: Maintains dependable communication between connected systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial-Grade Construction: Built for continuous operation in mission-critical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CMI-300 delivers the reliability and precision required for communication and network integration in Siemens MXL fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52141751107882,"sku":"CMI-300","price":917.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_9f673804-0a8d-4f35-a03d-74364ff7d8a8.webp?v=1785271704","url":"https:\/\/iqelectro.com\/products\/siemens-cmi-300-cxl-mxl-fire-alarm-communication-interface-module","provider":"IQElectro","version":"1.0","type":"link"}