{"product_id":"siemens-fn2006-u1-single-mode-fiber-optic-interface-module-for-fire-alarm-networks","title":"Siemens FN2006-U1 Single-Mode Fiber-Optic Interface Module for Fire Alarm Networks","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens FN2006-U1 is a single-mode fiber-optic interface module designed to transmit RS-485 and X-NET\/SafeDlink communication between compatible Siemens fire alarm control panels and fire terminals. It extends network connectivity over long-distance fiber-optic links, providing reliable communication for distributed commercial and industrial life safety systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 509.438px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eFN2006-U1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eFiber-Optic Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSingle-Mode Fiber Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eDuplex 9\/125 µm single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eFiber Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSC duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eRS-485, X-NET, SafeDlink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 39.1875px;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 39.1875px;\"\u003eFC2025\/FC2050 FACP or regulated 24 VDC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Power Supplies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003ePAD-3, PAD-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Fiber Segment Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 39.1875px;\"\u003e131,000 ft (40 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Network Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003e131,000 ft (40 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eDaisy-chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Control Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSiemens FC2025, FC2050, FireFinder XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSiemens FT2050 Fire Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 39.1875px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 39.1875px;\"\u003eDesigo 1HU or 2HU enclosure, COM-BRK for FireFinder XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eFM Approved, CSFM Listed, FDNY Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 39.1875px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 39.1875px;\"\u003eFiber-optic communication for fire alarm networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eApproximately 1.0 lb (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e FN2006-U1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe FN2006-U1 is part of the Siemens Desigo Fire Safety fiber-optic networking solution, developed for FC2025 and FC2050 fire alarm control panels, FT2050 Fire Terminal units, and compatible FireFinder XLS systems. Operating with duplex 9\/125 µm single-mode fiber, the module converts copper-based communication to optical transmission, allowing network expansion well beyond the limitations of standard RS-485 wiring. It supports peer-to-peer X-NET and SafeDlink communication in daisy-chain network configurations while maintaining high communication reliability between distributed fire alarm nodes. Powered from a compatible fire alarm control panel or an approved regulated 24 VDC supply, the module is engineered for dependable operation in mission-critical life safety installations.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-Mode Fiber Interface: Utilizes duplex 9\/125 µm single-mode fiber for long-distance communication.\u003c\/li\u003e\n\u003cli\u003eX-NET Communication: Supports Siemens X-NET peer-to-peer networking.\u003c\/li\u003e\n\u003cli\u003eSafeDlink Support: Enables SafeDlink communication between compatible fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eRS-485 Transmission: Converts RS-485 communication to fiber-optic transmission.\u003c\/li\u003e\n\u003cli\u003eLong-Distance Networking: Supports fiber segments up to 40 km (131,000 ft).\u003c\/li\u003e\n\u003cli\u003eDaisy-Chain Topology: Designed for distributed network architectures.\u003c\/li\u003e\n\u003cli\u003e24 VDC Operation: Powered directly from compatible Siemens fire alarm systems or approved external supplies.\u003c\/li\u003e\n\u003cli\u003eSC Fiber Connectors: Uses standard SC-style duplex fiber connectors.\u003c\/li\u003e\n\u003cli\u003eFireFinder XLS Compatibility: Integrates with compatible FireFinder XLS fire alarm panels.\u003c\/li\u003e\n\u003cli\u003eDesigo Fire Compatibility: Designed for FC2025, FC2050, and FT2050 platforms.\u003c\/li\u003e\n\u003cli\u003eCertified for Life Safety: Approved for commercial fire alarm installations with multiple industry certifications.\u003c\/li\u003e\n\u003cli\u003eReliable Fiber Communication: Maintains secure and stable data transmission across large facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FN2006-U1 delivers the reliability and precision required for long-distance fiber-optic communication in distributed fire alarm and life safety networks.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52141659619626,"sku":"FN2006-U1","price":4499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_4bb870c1-334f-40fa-8497-80cfd463c608.webp?v=1785270391","url":"https:\/\/iqelectro.com\/products\/siemens-fn2006-u1-single-mode-fiber-optic-interface-module-for-fire-alarm-networks","provider":"IQElectro","version":"1.0","type":"link"}