{"product_id":"siemens-hhed63b100-sentron-ed-frame-100a-3-pole-600v-molded-case-circuit-breaker","title":"Siemens HHED63B100 Sentron ED-Frame 100A 3-Pole 600V Molded Case Circuit Breaker","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Siemens HHED63B100 is a high-interrupting molded case circuit breaker designed to provide severe overcurrent and short-circuit protection in commercial electrical distribution systems. This 100-amp, three-pole protective device utilizes a robust thermal-magnetic trip mechanism to continuously monitor electrical loads and rapidly disconnect power during hazardous fault conditions. By securing critical branch circuits, the breaker prevents catastrophic damage to downstream industrial equipment and ensures continuous facility operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable height=\"350\" style=\"width: 85.2594%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eCondition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003eSiemens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eCategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003eElectrical Distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003eHHED63B100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eSubcategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003eCircuit Breakers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eAmperage Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003e100 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eMaximum Voltage Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003e600 VAC \/ 250 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eNumber of Poles\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eFrame Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003eED-Frame (HHED6)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eTrip Unit Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003eThermal-Magnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eInterrupting Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003e65 kA at 480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003ePhase Connection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003e3-Phase (ABC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003ePanel Mount \/ Bolt-On\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.9132%;\"\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.7752%;\"\u003e\u003cspan\u003e3.5 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eHHED63B100\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe HHED63B100 is an integral safety component of the Siemens Sentron ED-frame series, engineered with a compact, high-dielectric composite housing that safely contains internal arc flashes. It is equipped with a highly responsive thermal-magnetic trip unit that delivers reliable, fixed-parameter protection against both sustained overloads and instantaneous short circuits. Electrical technicians deploy this UL-listed breaker within main switchboards and distribution panels requiring a robust 65 kA interrupting capacity at 480 VAC. The architecture features standard bolt-on or lug connections, facilitating secure mechanical integration directly into high-capacity industrial busbar infrastructure.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e● Thermal-Magnetic Trip Unit: Combines temperature-sensitive bimetal elements and electromagnetic sensors to precisely detect varying electrical fault profiles.\u003cbr\u003e● High Interrupting Capacity: Delivers an exceptional 65 kA interrupting rating at 480 VAC to safely clear severe industrial electrical faults.\u003cbr\u003e● ED-Frame Construction: Utilizes a compact, high-strength molded case housing to conserve valuable space within crowded commercial switchboards.\u003cbr\u003e● Three-Pole Configuration: Engineered specifically to regulate and protect three-phase alternating current power within demanding factory networks.\u003cbr\u003e● Phase Isolation Barriers: Incorporates specialized internal arc chutes to suppress electrical arcing and prevent dangerous phase-to-phase flashovers during a trip.\u003cbr\u003e● Fixed Trip Settings: Features predetermined thermal and magnetic trip thresholds to simplify field installation and prevent accidental miscalibration.\u003cbr\u003e● Broad Voltage Range: Rated for safe continuous operation up to 600 VAC, accommodating a wide variety of heavy-duty industrial applications.\u003cbr\u003eThe HHED63B100 delivers the reliability and precision required for secure power distribution and catastrophic fault prevention in commercial electrical networks.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52612875321642,"sku":"HHED63B100","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/siemens-hhed63b100-3-pole-100-amp-600v-circuit-breaker-iso-600.jpg?v=1789482099","url":"https:\/\/iqelectro.com\/products\/siemens-hhed63b100-sentron-ed-frame-100a-3-pole-600v-molded-case-circuit-breaker","provider":"IQElectro","version":"1.0","type":"link"}