{"product_id":"siemens-lfl1-635-220-240v-gas-burner-sequence-controller-with-60s-purge","title":"Siemens LFL1.635 220–240V Gas Burner Sequence Controller with 60s Purge","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Siemens LFL1.635 is a burner sequence controller designed for medium- to high-capacity gas, oil, and dual-fuel burners. It operates from a 220–240 VAC supply and provides flame supervision, burner sequencing, and a fixed 60-second prepurge function for intermittent burner operation.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 70%; height: 394.93px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eLFL1.635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.7778px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.7778px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.7778px;\"\u003eBurner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eLFL1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eGas, Oil, and Dual-Fuel Burners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003e220–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 39.1944px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 39.1944px;\"\u003e3.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003ePrepurge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eFlame Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eUV Detector QRA... \/ Ionization Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.4028px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 22.4028px;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 22.4028px;\"\u003ePlug-in Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eCompatible Bases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eAGM410490550, AGM14.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 39.1944px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 39.1944px;\"\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 34.1379%; height: 19.5972px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1724%; height: 19.5972px;\"\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eLFL1.635\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe LFL1.635 belongs to the Siemens LFL1 series of burner control and flame safeguard units. It is suitable for multistage or modulating burners with checked air damper control and intermittent operation. Flame supervision can be provided using compatible QRA UV flame detectors or an ionization probe, while compatible SQN-series actuators can be used for air damper and burner control. The controller is designed for plug-in installation with compatible AGM410490550 or AGM14.1 bases and has an IP40 degree of protection.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eLFL1 Series: Part of Siemens' LFL1 family of burner sequence controllers.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eGas, Oil, and Dual-Fuel Compatibility: Designed for medium- to high-capacity burners using gaseous, liquid, or dual fuels.\u003c\/li\u003e\n\u003cli\u003e220–240 VAC Supply: Operates from a 220–240 VAC AC power supply at 50–60 Hz.\u003c\/li\u003e\n\u003cli\u003e60-Second Prepurge: Provides a fixed 60-second purge period within the burner sequence.\u003c\/li\u003e\n\u003cli\u003eFlame Supervision: Supports flame monitoring with QRA UV detectors or an ionization probe.\u003c\/li\u003e\n\u003cli\u003eBurner Sequencing: Controls and supervises the operating sequence of compatible burner systems.\u003c\/li\u003e\n\u003cli\u003eActuator Compatibility: Supports compatible Siemens SQN-series burner and air-damper actuators.\u003c\/li\u003e\n\u003cli\u003eIP40 Protection: Provides a defined level of protection for installation in suitable control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe LFL1.635 delivers the burner sequencing and flame-safety control required for medium- and high-capacity industrial burner systems.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52755691536682,"sku":"LFL1.635","price":615.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l960_a7bbe903-871b-475a-b30e-1eab1e96a92b.webp?v=1790412272","url":"https:\/\/iqelectro.com\/products\/siemens-lfl1-635-220-240v-gas-burner-sequence-controller-with-60s-purge","provider":"IQElectro","version":"1.0","type":"link"}