{"product_id":"siemens-lgk16-333a27-gas-burner-control-230vac-31-5s-prepurge","title":"Siemens LGK16.333A27 Gas Burner Control 230VAC 31.5s Prepurge","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"514\"\u003eThe Siemens LGK16.333A27 is a 7800 Series gas burner control designed for forced-draft gas burners and flame supervision applications. It operates at 230 VAC, 50–60 Hz and provides a 31.5-second prepurge time with the air damper open and a 3-second safety time. The controller is designed for flame supervision using compatible QRA53\/QRA55 UV flame detectors or an ionization probe.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 70%; height: 450.736px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eHVAC \u0026amp; Burner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eLGK16.333A27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eGas Burner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eLGK16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eGas Burner Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eForced-Draft Gas Burners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003e230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003ePrepurge Time (t1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003e31.5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eSafety Time (TSA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003e3 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003ePreignition Time (t3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003e6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003ePost-Purge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003e17 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eFlame Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eQRA53\/QRA55 UV Detector or Ionization Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eFlame Signal Amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eSelf-Checking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eAir Pressure Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003ePrimary Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eT6.3H250V built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eExternal Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eMax. 16 A slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003ePlug-In Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eOrdered Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eFlame Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eOrdered Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eMaximum Total Connected Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003e2000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003eApprox. 5 × 5 × 5 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8123%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6475%;\"\u003e2.26 lb \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About LGK16.333A27\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"505\" data-end=\"1008\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe LGK16.333A27 is a Siemens gas burner control for medium- to high-capacity forced-draft burners, including multistage or modulating burner systems. It provides automatic burner sequencing, air-pressure supervision, ignition control, and flame monitoring. The unit operates from 230 VAC and is intended to be used with a suitable plug-in base and compatible flame detector, which are ordered separately. Siemens specifies a 31.5-second prepurge time and a 3-second safety time for this particular model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1291\" data-end=\"2127\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"703\" data-end=\"1384\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"730\" data-end=\"1339\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1105\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1027\" data-end=\"1844\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1022\" data-end=\"1720\"\u003e\n\u003cli data-section-id=\"de0ber\" data-start=\"1022\" data-end=\"1120\"\u003eGas Burner Control: Provides automatic sequencing and safety control for industrial gas burners.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9qf8g6\" data-start=\"1121\" data-end=\"1187\"\u003e230 VAC Operation: Designed for 230 VAC, 50–60 Hz power systems.\u003c\/li\u003e\n\u003cli data-section-id=\"4rocde\" data-start=\"1188\" data-end=\"1276\"\u003e31.5-Second Prepurge: Provides a 31.5-second prepurge period with the air damper open.\u003c\/li\u003e\n\u003cli data-section-id=\"gfkwmw\" data-start=\"1277\" data-end=\"1344\"\u003e3-Second Safety Time: Provides a 3-second ignition safety period.\u003c\/li\u003e\n\u003cli data-section-id=\"1ds9h3s\" data-start=\"1345\" data-end=\"1429\"\u003eFlame Supervision: Supports QRA53\/QRA55 UV flame detectors or an ionization probe.\u003c\/li\u003e\n\u003cli data-section-id=\"elyef0\" data-start=\"1430\" data-end=\"1531\"\u003eAir Pressure Supervision: Supports monitoring of the combustion air supply during burner operation.\u003c\/li\u003e\n\u003cli data-section-id=\"6xxbw1\" data-start=\"1532\" data-end=\"1618\"\u003eModulating Applications: Suitable for multistage or modulating forced-draft burners.\u003c\/li\u003e\n\u003cli data-section-id=\"1wfmc3r\" data-start=\"1619\" data-end=\"1720\"\u003eSelf-Checking Amplifier: Incorporates a self-checking flame-signal amplifier for flame supervision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"1722\" data-end=\"1901\"\u003eThe LGK16.333A27 delivers the control and monitoring functions required for industrial burner-management and combustion-control applications.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52782818066730,"sku":"LGK16.333A27","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l500_cbb76065-9dd3-4546-b319-76e74bd9d1f4.webp?v=1790582881","url":"https:\/\/iqelectro.com\/products\/siemens-lgk16-333a27-gas-burner-control-230vac-31-5s-prepurge","provider":"IQElectro","version":"1.0","type":"link"}