{"product_id":"siemens-zic-4a-zone-card-module-for-fire-panels-available-now","title":"ZIC-4A | Siemens Zone Card with 4 Supervised Initiating Circuits for Fire Alarm Panels","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"396\"\u003eThe Siemens ZIC-4A is a fire alarm control panel zone card designed to provide four conventional initiating device circuits. It expands the input capacity of compatible Siemens fire alarm systems for supervised zone monitoring.\u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 333.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eZIC-4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eZone Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eFire alarm initiating device circuit card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eAdds conventional supervised input zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eSiemens fire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eDetectors, pull stations, and initiating devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eMonitors for open, short, and alarm conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003ePlug-in modular card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eFire alarm zone expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eCommercial, institutional, and industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eUL listed (where applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eStandard Siemens module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003e1 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About ZIC-4A\u003c\/h4\u003e\n\u003cp\u003eThe ZIC-4A is part of Siemens’ modular fire alarm system components, developed to add supervised initiating device circuits (IDCs) to control panels. Each card provides four additional conventional zones for connecting detectors, pull stations, and other initiating devices. It ensures proper circuit supervision for open and short conditions, maintaining system integrity and code compliance. Designed for use in Siemens fire alarm panels, the ZIC-4A supports scalable system configurations in commercial, institutional, and industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour IDC Circuits: Expands system input with four supervised initiating device circuits.\u003c\/li\u003e\n\u003cli\u003eZone Monitoring: Connects smoke detectors, heat detectors, and manual pull stations.\u003c\/li\u003e\n\u003cli\u003eSupervised Inputs: Detects open, short, and alarm conditions for system integrity.\u003c\/li\u003e\n\u003cli\u003eSystem Integration: Designed for Siemens fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eModular Expansion: Field-installable for scalable configurations.\u003c\/li\u003e\n\u003cli\u003eCommercial Use: Suitable for large-scale building fire alarm installations.\u003c\/li\u003e\n\u003cli\u003eReliable Operation: Ensures dependable zone monitoring in critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ZIC-4A delivers the reliability and precision required for supervised zone expansion in Siemens fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":50651367080234,"sku":"ZIC-4A","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/ZIC-4A.jpg?v=1759394662","url":"https:\/\/iqelectro.com\/products\/siemens-zic-4a-zone-card-module-for-fire-panels-available-now","provider":"IQElectro","version":"1.0","type":"link"}