{"product_id":"simplex-2190-9155-class-b-monitor-zone-addressable-module-for-mapnet-ii-fire-alarm-systems","title":"Simplex 2190-9155 Class B Monitor Zone Addressable Module for MAPNET II Fire Alarm Systems","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Simplex 2190-9155 is a Class B Monitor Zone Addressable Module designed to connect conventional initiating device circuits to Simplex addressable fire alarm systems. It monitors the connected zone as an individually addressed point and communicates its status to the fire alarm control panel through the MAPNET II network.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2190-9155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZone Addressable Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitor Zone Addressable Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B, Style B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMAPNET II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate 24 volts direct current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervisory Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 milliamperes at 24 volts direct current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 milliamperes at 24 volts direct current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex 4100, 4100U, 4120, Universal Transponders, and 2120 Communicating Device Transponders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd-of-Line Resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.8 kilohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex 4090-9101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0617606\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 × 5.5 × 2 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About 2190-9155\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe 2190-9155 is a Simplex MAPNET II Zone Addressable Module configured as a Class B, Style B monitor interface with a surface-mount cover. Its circuitry provides an addressable interface for conventional initiating devices while using a separately supplied 24-volt direct-current source for module operation. The module is compatible with MAPNET II-equipped Simplex 4100 and 4100U Series panels, 4100 Series Universal Transponders, 4120 Series network node panels, and 2120 Communicating Device Transponders. It is a legacy discontinued device, with Simplex 4090-9101 identified as its replacement for applications requiring a current monitor Zone Addressable Module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eClass B Monitoring: Provides a Class B, Style B interface for monitoring a conventional initiating device circuit as an addressable fire alarm point. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMAPNET II Communication: Communicates with compatible Simplex control equipment through the MAPNET II addressable network. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eConventional Circuit Integration: Allows conventional initiating devices to be incorporated into an addressable Simplex fire alarm architecture. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSurface-Mount Configuration: The 2190-9155 version is supplied in the surface-cover configuration; 2190-9156 is the corresponding flush-cover version. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeparate Power Input: Requires a separate 24-volt direct-current power supply in addition to MAPNET II communication wiring. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDefined Current Requirements: Draws approximately 20 milliamperes during supervision and 90 milliamperes during alarm at 24 volts direct current. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eLegacy System Compatibility: Supports MAPNET II-equipped Simplex 4100, 4100U, 4120, Universal Transponder, and 2120 system architectures. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eReplacement Availability: The discontinued 2190-9155 is identified in replacement-market documentation as superseded by the Simplex 4090-9101 Monitor Zone Addressable Module. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 2190-9155 delivers the reliability and precision required for supervised integration of conventional initiating device circuits into compatible Simplex addressable fire alarm systems.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":52614261276970,"sku":"2190-9155","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/2190-9155-1.jpg?v=1789499853","url":"https:\/\/iqelectro.com\/products\/simplex-2190-9155-class-b-monitor-zone-addressable-module-for-mapnet-ii-fire-alarm-systems","provider":"IQElectro","version":"1.0","type":"link"}