{"product_id":"simplex-4098-9713-truealarm-quickconnect-photoelectric-smoke-sensor-with-sounder","title":"Simplex 4098-9713 TrueAlarm QuickConnect Photoelectric Smoke Sensor with Sounder","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Simplex 4098-9713 is a TrueAlarm QuickConnect photoelectric smoke sensor with an integrated sounder for addressable fire alarm systems. It provides smoke detection and local audible notification through compatible Simplex IDNet fire alarm control panels and is intended for commercial and institutional fire detection applications.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable height=\"428\" style=\"width: 92.254733%; height: 349.484375px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003eSimplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003eFire Alarm \u0026amp; Detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003e4098-9713\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003ePhotoelectric Smoke Detectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 38px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 38px;\"\u003e\u003cspan\u003eTrueAlarm QuickConnect Photoelectric Smoke Sensor with Sounder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003e\u003cspan\u003eDetection Technology\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003ePhotoelectric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003eIDNet addressable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003eTrueAlarm QuickConnect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003e\u003cspan\u003eIntegrated Notification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003eSounder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003e\u003cspan\u003eSounder Power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003eI\u003cspan\u003e24 VDC\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42.328125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 42.328125px;\"\u003e\u003cstrong\u003e\u003cspan\u003eSensitivity Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 42.328125px;\"\u003e\u003cspan\u003e1.5%\/ft to 3.7%\/ft smoke obscuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 13.3125px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Panels\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 13.3125px;\"\u003e\u003cspan\u003eSimplex 4010, 4100, 4120 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3125px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.3125px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.3125px;\"\u003e\u003cspan\u003e4-inch square or octagonal electrical box; compatible single-gang configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.40625px;\"\u003e\n\u003ctd style=\"width: 30.898876%; height: 21.40625px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.977528%; height: 21.40625px;\"\u003e\u003cspan\u003e0.40 lb (0.18 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About 4098-9713\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe 4098-9713 is part of the Simplex TrueAlarm QuickConnect family of addressable smoke sensors with sounder functionality. Its QuickConnect design uses a single wiring connection for the sensor while the integrated sounder additionally requires 24 VDC power for sounder operation. The device is compatible with Simplex systems including the 4010, 4100, and 4120 series, with system-specific compatibility determined by the fire alarm control panel configuration. The sensor is designed for installation on standard electrical boxes and supports applications requiring monitored photoelectric smoke detection with local audible notification.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eTrueAlarm Photoelectric Detection: Provides addressable photoelectric smoke sensing with control-panel-monitored sensitivity.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eQuickConnect Technology: Allows the sensor assembly to connect to its mounting arrangement without a conventional separate sensor base.\u003c\/li\u003e\n\u003cli\u003eIntegrated Sounder: Provides local audible notification as part of the sensor assembly.\u003c\/li\u003e\n\u003cli\u003eIDNet Compatibility: Designed for use with compatible Simplex addressable fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003ePanel Compatibility: Supports Simplex 4010, 4100, and 4120 series systems, subject to panel configuration.\u003c\/li\u003e\n\u003cli\u003eSensitivity Range: The 4098-9713 has a specified smoke obscuration sensitivity range of 1.5%\/ft to 3.7%\/ft.\u003c\/li\u003e\n\u003cli\u003eElectrical Installation: Sensor wiring uses a terminal connection arrangement and the sounder requires additional 24 VDC power.\u003c\/li\u003e\n\u003cli\u003eMounting Flexibility: Can be installed on 4-inch square or octagonal electrical boxes and specified single-gang configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4098-9713 delivers the reliability and precision required for addressable commercial and institutional fire detection systems.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":52440808620330,"sku":"4098-9713","price":822.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_1d005345-61bb-4e1c-984c-77d9328fc384.webp?v=1788262436","url":"https:\/\/iqelectro.com\/products\/simplex-4098-9713-truealarm-quickconnect-photoelectric-smoke-sensor-with-sounder","provider":"IQElectro","version":"1.0","type":"link"}