{"product_id":"simplex-4098-9792-addressable-truealarm-sensor-base-for-fire-alarm-systems","title":"Simplex 4098-9792 Addressable TrueAlarm Sensor Base for Fire Alarm Systems","description":"\u003ch4\u003eDescription\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Simplex 4098-9792 is an addressable standard sensor base designed to provide a secure communication interface for TrueAlarm analog detector heads. It supports reliable transmission of sensor data over IDNet and MAPNET II signaling circuits while simplifying installation, maintenance, and detector replacement in commercial fire alarm systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4098-9792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Sensor Bases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable standard sensor base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex TrueAlarm analog photoelectric and heat detector heads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIDNet, IDNet+, IDNet 1+, IDNet 2, IDNet 2+2, MAPNET II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Reporting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor polled and reported every 4 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic detector recognition with default sensitivity assignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuity Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral shorting-spring contacts for SLC continuity testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTesting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic functional test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocking anti-tamper design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeiling or wall; fits standard 4 in. or single-gang electrical back boxes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote LED, supervised relays, LED annunciation relay, adapter plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Control Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex 4007ES, 4008, 4010, 4010ES, 4020, 4100, 4100+, 4100U, 4100ES, 4120, 2120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 268 7th Edition, ULC-S529, NEMA 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.2 lb (0.09 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 4098-9793\u003c\/h4\u003e\n\u003cp\u003eThe 4098-9792 is an addressable sensor base from the Simplex TrueAlarm product family, engineered for use with compatible photoelectric and heat detector heads. It features integrated addressable electronics that poll the connected detector and transmit status information to the fire alarm control panel every four seconds. Automatic sensor identification allows the control panel to recognize replacement detector types and apply appropriate default sensitivity settings without reprogramming. Designed for commercial fire protection systems, the base supports ceiling or wall mounting and includes built-in testing, anti-tamper protection, and continuity testing features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAddressable Sensor Base:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides communication and mounting for Simplex TrueAlarm detector heads.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIDNet \u0026amp; MAPNET II Communication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports multiple Simplex signaling line circuit protocols.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Sensor Identification:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detects installed sensor type and applies default configuration automatically.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eContinuous Status Polling:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Reports detector status to the control panel every four seconds.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShorting Spring Contacts:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Maintain SLC continuity during detector installation or removal.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMagnetic Test Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Enables functional testing without removing the detector.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAnti-Tamper Lock:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Secures the detector head to prevent unauthorized removal.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOptional Accessory Support:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible with remote LEDs, relays, and adapter plates for expanded installation flexibility.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4098-9792\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers the reliability and precision required for addressable fire alarm detector installations and communication networks.\u003c\/span\u003e\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":51912980136234,"sku":"4098-9793","price":104.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/iqelectro.com\/products\/simplex-4098-9792-addressable-truealarm-sensor-base-for-fire-alarm-systems","provider":"IQElectro","version":"1.0","type":"link"}