{"product_id":"simplex-4100-3101-idnet-module-card-available-now","title":"Simplex 4100-3101 IDNet Communication Module (250-Point) for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Simplex 4100-3101 IDNet Module is an intelligent communication interface card that allows a fire alarm control panel to support up to 250 addressable IDNet devices. It provides high-speed digital signaling between the system CPU and field detection or notification devices over a single two-wire circuit.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLCs\/Machine Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4100-3101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLC Module\/Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIDNet Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex 4100U \/ 4100ES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 250 addressable IDNet points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIDNet two-wire signaling line circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC supplied from the control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDNet Loop Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 VDC nominal or 36 VDC at 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Wiring Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 feet (3,048 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 40 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.60 μF (line-to-line and shield-to-line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in card to power distribution interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\" × 5\" circuit card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.30 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e4100-3101\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 4100-3101 is part of the Simplex 4100U and 4100ES system platform, serving as the IDNet channel interface that connects detectors, modules, and manual stations on the addressable loop. The module installs directly into the panel’s power distribution interface and communicates with field devices via IDNet signaling. With a communication range of up to 10,000 feet, it ensures stable data transmission across extensive installations. The 4100-3101 is designed for industrial-grade reliability and is UL Listed for fire alarm applications. Though discontinued, it remains a critical component for maintaining existing 4100-series systems, with the 4100-3102 serving as its functional replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e250-Point Capacity: Supports up to 250 addressable IDNet devices on one loop.\u003c\/li\u003e\n\u003cli\u003ePanel Compatibility: Designed for use with Simplex 4100ES and 4100U fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eReliable Communication: Digital signaling over a two-wire IDNet SLC loop.\u003c\/li\u003e\n\u003cli\u003eExtended Wiring Distance: Supports wiring runs up to 10,000 feet.\u003c\/li\u003e\n\u003cli\u003ePower Supply Integration: Operates from the FACP 24 VDC source with 30–36 VDC IDNet output.\u003c\/li\u003e\n\u003cli\u003eHigh Device Density: Ideal for large facilities requiring multiple addressable detection points.\u003c\/li\u003e\n\u003cli\u003eCompact Design: 4” × 5” plug-in circuit card for efficient space use.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Certified for fire alarm applications and code compliance.\u003c\/li\u003e\n\u003cli\u003eLine Tolerance: Handles up to 40 Ohms line resistance and 0.60 μF capacitance.\u003c\/li\u003e\n\u003cli\u003eSuggested Replacement: Superseded by model 4100-3102 in current production systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4100-3101 delivers dependable addressable device communication and high capacity for intelligent Simplex 4100-series fire alarm systems.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":50660007706922,"sku":"4100-3101","price":1675.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_5fd48187-175d-4c10-9868-8a7f6a885e44.webp?v=1759691836","url":"https:\/\/iqelectro.com\/products\/simplex-4100-3101-idnet-module-card-available-now","provider":"IQElectro","version":"1.0","type":"link"}