{"product_id":"simplex-4100-3102-mapnet-ii-127-point-addressable-interface-module","title":"Simplex 4100-3102 MAPNET II 127-Point Addressable Interface Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Simplex 4100-3102 is a MAPNET II addressable interface module designed for compatible Simplex 4100 Series fire alarm control systems. It provides communication with up to 127 addressable MAPNET II devices and occupies two module slots within the fire alarm control unit.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable height=\"650\" style=\"width: 81.5374%; height: 511.587px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 23.3625px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 23.3625px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 23.3625px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003eFire Alarm System Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e4100-3102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003eMAPNET II Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e4100 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.85px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 47.85px;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 47.85px;\"\u003eMAPNET II Addressable Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eMaximum Addressable Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003eMAPNET II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003eClass A or Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eModule Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e2 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eDevice Loading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e1.7 mA per MAPNET II device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eModule Standby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e255 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eModule Alarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e275 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eFully Loaded Standby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e471 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eFully Loaded Alarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003e491 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eInstallation Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003eCPU bay or expansion bay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.375px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.375px;\"\u003e\u003cstrong\u003eAssembly Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.375px;\"\u003eMotherboard and daughter card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.85px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 25.85px;\"\u003e\u003cstrong\u003eSystem Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 25.85px;\"\u003eAddressable fire alarm detection and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.525px;\"\u003e\n\u003ctd style=\"width: 46.7245%; height: 24.525px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.0097%; height: 24.525px;\"\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About 4100-3102\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe 4100-3102 is part of the Simplex 4100 Series addressable interface module family and provides a MAPNET II signaling line interface. The module uses a two-card transceiver assembly consisting of a motherboard and daughter card installed within a compatible CPU or expansion bay. It supports up to 127 MAPNET II addressable devices, with each connected device contributing approximately 1.7 mA of loading. The module supports either Class A or Class B wiring for the connected MAPNET II circuit.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMAPNET II Interface: Provides addressable communication between a Simplex 4100 control panel and MAPNET II field devices.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e127-Point Capacity: Supports up to 127 addressable MAPNET II devices on the interface.\u003c\/li\u003e\n\u003cli\u003eTwo-Slot Module: Occupies two module slots within the compatible Simplex fire alarm control unit.\u003c\/li\u003e\n\u003cli\u003eClass A\/B Wiring: Supports either Class A or Class B MAPNET II circuit configurations.\u003c\/li\u003e\n\u003cli\u003eTransceiver Architecture: Uses a motherboard and daughter-card configuration for MAPNET II communication.\u003c\/li\u003e\n\u003cli\u003eDevice Loading: Each MAPNET II device contributes approximately 1.7 mA of circuit loading.\u003c\/li\u003e\n\u003cli\u003eSupervised Operation: Provides monitored communication between the control panel and connected addressable devices.\u003c\/li\u003e\n\u003cli\u003e4100 Series Compatibility: Designed for use with compatible Simplex 4100 Series fire alarm control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4100-3102 delivers the reliability and precision required for addressable fire alarm device communication and MAPNET II circuit management.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":52442584285482,"sku":"4100-3102","price":645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/4100-3102-e1616510313612.png?v=1788200447","url":"https:\/\/iqelectro.com\/products\/simplex-4100-3102-mapnet-ii-127-point-addressable-interface-module","provider":"IQElectro","version":"1.0","type":"link"}