{"product_id":"simplex-4100-6033-fire-alarm-relay-card-with-alarm-trouble-and-supervisory-outputs-for-compatible-panels","title":"Simplex 4100-6033 Fire Alarm Relay Card with Alarm, Trouble, and Supervisory Outputs for Compatible Panels","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eSimplex \u003c\/span\u003e\u003cspan\u003e4100-\u003c\/span\u003e\u003cspan\u003e6033 \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003efire \u003c\/span\u003e\u003cspan\u003ealarm \u003c\/span\u003e\u003cspan\u003erelay \u003c\/span\u003e\u003cspan\u003ecard \u003c\/span\u003e\u003cspan\u003ethat \u003c\/span\u003e\u003cspan\u003eprovides \u003c\/span\u003e\u003cspan\u003eseparate \u003c\/span\u003e\u003cspan\u003ealarm, \u003c\/span\u003e\u003cspan\u003etrouble, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003esupervisory \u003c\/span\u003e\u003cspan\u003eoutputs. \u003c\/span\u003e\u003cspan\u003eIt \u003c\/span\u003e\u003cspan\u003einterfaces \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003efire \u003c\/span\u003e\u003cspan\u003ealarm \u003c\/span\u003e\u003cspan\u003epanels \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003eexternal \u003c\/span\u003e\u003cspan\u003eindication \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eequipment, \u003c\/span\u003e\u003cspan\u003eincluding \u003c\/span\u003e\u003cspan\u003efans \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003edoors, \u003c\/span\u003e\u003cspan\u003ethrough \u003c\/span\u003e\u003cspan\u003eunsupervised \u003c\/span\u003e\u003cspan\u003erelay \u003c\/span\u003e\u003cspan\u003ecircuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4100-6033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay\/Socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm relay card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible Simplex 4100U and 4100ES configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm, trouble, and supervisory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForm C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A at 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Contact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJumper-selectable normally open or normally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnsupervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent with All Relays Energized\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree relay energization LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTB1 terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–120°F (0–49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–93% RH, non-condensing, at 90°F (32°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About 4100-6033\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe 4100-6033 is a panel accessory documented for compatible Simplex 4100U and 4100ES systems. Its circuit board contains three relays, individual status indicators, configuration jumpers, and a field wiring terminal block. The card mounts to a supported power supply assembly and connects through a power\/communication harness. Jumper settings select normally open or normally closed operation for each output, with the installed option enabled through panel programming.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThree Status Outputs: Provides dedicated circuits for alarm, trouble, and supervisory conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eForm C Relays: Uses three relays rated 2 A at 32 VDC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelectable Contact Operation: Individual jumpers configure normally open or normally closed field circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelay Indicators: Three LEDs identify energized relay states.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExternal Equipment Interface: Supports common control or indication functions for compatible connected equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal Block Wiring: TB1 provides field connections for the relay circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower Supply Mounting: Installs on supported Simplex power supply assemblies.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe 4100-6033 delivers the reliability and precision required for fire alarm status interfacing and auxiliary equipment control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":53419827659050,"sku":"4100-6033","price":252.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/61F1uqWRpyL.jpg_BO30_255_255_255_UF750_750_SR1910_1000_0_C_QL100.jpg?v=1793563585","url":"https:\/\/iqelectro.com\/products\/simplex-4100-6033-fire-alarm-relay-card-with-alarm-trouble-and-supervisory-outputs-for-compatible-panels","provider":"IQElectro","version":"1.0","type":"link"}