{"product_id":"simplex-566-736-mapnet-ii-transceiver-board-in-stock","title":"566-736 | Simplex MapNet II Transceiver Board for 4100 Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Simplex 566-736 is a MapNet II transceiver board designed for use with 4100 fire alarm systems. It serves as an interface module for the 4100-3102 and provides reliable communication between control panels and MapNet II addressable devices.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLCs\/Machine Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e566-736\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC Board PLC\/Add-On Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMapNet II transceiver \/ interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex 4100 Series Fire Alarm Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4100-3102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMapNet II addressable SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMapNet II detectors, modules, and notification appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull line and device supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal panel slot installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm signaling and device integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse Case\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy MapNet II system maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e566-736\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 566-736 is a dedicated transceiver board that enables Simplex 4100 series fire alarm control panels to communicate over the MapNet II signaling line circuit (SLC). It converts panel-level signals into MapNet II protocol, allowing addressable devices such as detectors, modules, and control points to function within the system. Designed as a direct interface for the 4100-3102, this board provides robust and supervised data transmission. Although discontinued, it remains essential for servicing legacy installations still operating with MapNet II technology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMapNet II Transceiver: Provides communication between panels and addressable devices.\u003c\/li\u003e\n\u003cli\u003e4100 Compatibility: Designed for use with Simplex 4100 series panels.\u003c\/li\u003e\n\u003cli\u003eInterface Module: Works directly with 4100-3102 boards.\u003c\/li\u003e\n\u003cli\u003eAddressable Device Support: Enables use of MapNet II detectors and modules.\u003c\/li\u003e\n\u003cli\u003eSupervised Communication: Monitors signal integrity across the SLC.\u003c\/li\u003e\n\u003cli\u003eReliable Integration: Ensures smooth panel-to-device connectivity.\u003c\/li\u003e\n\u003cli\u003eLegacy System Role: Essential for maintaining older MapNet II fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eCompact PCB Design: Circuit board format for internal installation.\u003c\/li\u003e\n\u003cli\u003eDiscontinued Part: No longer manufactured, available only for repair\/maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 566-736 delivers the reliability and precision required for MapNet II communications in Simplex 4100 fire alarm systems.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":50644239286570,"sku":"566-736","price":644.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/Simplex-566-736-Transceiver-board.jpg?v=1759233016","url":"https:\/\/iqelectro.com\/products\/simplex-566-736-mapnet-ii-transceiver-board-in-stock","provider":"IQElectro","version":"1.0","type":"link"}