{"product_id":"square-d-bda24020y1-20a-2-pole-circuit-breaker-ships-overnight","title":"BDA24020Y1 | Square D 20A 2-Pole PowerPact B I-Line Molded Case Circuit Breaker 480Y\/277VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"0\" data-end=\"451\"\u003eThe Square D BDA24020Y1 is a 20A, two-pole molded case circuit breaker designed for dependable protection in 480Y\/277VAC electrical systems. Its thermal-magnetic trip system provides responsive performance during overload and high-fault conditions. Featuring I-Line mounting, it is suited for industrial distribution panels requiring secure, plug-in installation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBDA24020Y1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerPact B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBDA Frame \/ 125A BD Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480Y\/277VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-Phase (AB Phase Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18kAIC @ 480VAC; 25kAIC @ 277\/408VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic (Long-Time \u0026amp; Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line (Line Side) \/ Mechanical Lug (Load Side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 to 2\/0 AWG Cu\/Al\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C (-13°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, CE, IEC, NEMA, NOM, CCC, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No.5, EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800V IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles @ 440V In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.12 in x 5.39 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About BDA24020Y1\u003c\/h4\u003e\n\u003cp data-start=\"590\" data-end=\"1074\" class=\"\"\u003eThe BDA24020Y1 is part of the PowerPact B Series, engineered for compact, versatile protection in commercial and industrial applications. Built on the BDA frame, it supports standardized I-Line plug-in mounting for quick integration into electrical distribution equipment. This breaker uses a dual-function thermal-magnetic trip unit providing long-time and instantaneous protection, making it suitable for mixed-load environments. Its compatibility with wire sizes from 14 to 2\/0 AWG and its broad certification set ensure reliable performance across varied installation standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e20A Current Rating: Designed for low-to-moderate load circuits requiring stable overcurrent protection.\u003c\/li\u003e\n\u003cli\u003eTwo-Pole Operation: Provides simultaneous disconnection for systems using AB phase connections.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Protection: Delivers long-time and instantaneous trip functions for overload and short-circuit events.\u003c\/li\u003e\n\u003cli\u003eI-Line Plug-In Mounting: Ensures secure installation in industrial distribution panels with standardized I-Line bus connections.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupt Ratings: Supports 18 kAIC at 480VAC and 25 kAIC at 277\/408VAC for demanding distribution environments.\u003c\/li\u003e\n\u003cli\u003eWide Wire Range: Accepts 14 to 2\/0 AWG copper or aluminum conductors for flexible installation.\u003c\/li\u003e\n\u003cli\u003eGlobal Certifications: Meets UL, CSA, CE, IEC, NEMA, CCC, NOM, and EAC standards for broad compliance.\u003c\/li\u003e\n\u003cli\u003eIndustrial Durability: Rated for continuous operation up to 70°C and designed for harsh electrical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BDA24020Y1 delivers the reliability and precision required for modern molded case circuit protection in industrial distribution systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50852698095914,"sku":"BDA24020Y1","price":709.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/files_39c273d9-aa40-4ded-b99b-abfd7c99cac5.jpg?v=1763584260","url":"https:\/\/iqelectro.com\/products\/square-d-bda24020y1-20a-2-pole-circuit-breaker-ships-overnight","provider":"IQElectro","version":"1.0","type":"link"}