{"product_id":"square-d-egb34060sa-60-ampere-3-pole-480y-277-volt-molded-case-circuit-breaker","title":"Square D EGB34060SA 60-Ampere 3-Pole 480Y\/277-Volt Molded Case Circuit Breaker","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Square D by Schneider Electric EGB34060SA is a three-pole E-Frame circuit breaker rated for 60 amperes and 480Y\/277 volts alternating current. It provides thermal-magnetic overload and short-circuit protection for electrical distribution systems and is designed for bolt-on installation in compatible Square D NF panelboards.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.9318%; height: 372.413px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eSquare D by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eEGB34060SA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eEGB E-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eThree-Pole Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003e60 amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eMaximum Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003e480Y\/277 volts alternating current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating at 480Y\/277 Volts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003e35 kiloamperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating at 240 Volts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003e65 kiloamperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eThermal-Magnetic with Shunt Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003e50\/60 hertz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003ePanelboard Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003eSquare D NF Panelboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003e5.8 × 2.94 × 4.05 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 52.5808%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.017%; height: 19.6007px;\"\u003e4.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About EGB34060SA\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe EGB34060SA is a Square D EGB Series E-Frame circuit breaker manufactured by Schneider Electric for commercial electrical distribution and lighting panelboard applications. The unit combines a three-pole configuration, 60-ampere continuous current rating, thermal-magnetic protection, and an integrated shunt-trip function in a bolt-on enclosure. It is designed for 480Y\/277-volt alternating-current systems and provides an interrupting rating of 35 kiloamperes at 480Y\/277 volts and 65 kiloamperes at 240 volts. The breaker is intended for compatible Square D NF panelboards and incorporates Visi-Trip indication to provide a visible indication when the device has tripped.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e60-Ampere Rating: Provides a rated continuous current capacity of 60 amperes for compatible branch and distribution circuits. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Simultaneously protects three conductors in compatible three-phase electrical distribution applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e480Y\/277-Volt Operation: Designed for electrical systems with a maximum operating voltage of 480Y\/277 volts alternating current. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Protection: Uses thermal and magnetic trip functions to respond to sustained overloads and high-current short-circuit conditions. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated at 35 kiloamperes at 480Y\/277 volts and 65 kiloamperes at 240 volts alternating current. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eShunt-Trip Function: Includes a shunt-trip accessory for electrically initiated breaker tripping from an external control circuit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Uses a bolted connection for secure installation in compatible Square D NF panelboards. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrip Indication: Incorporates Visi-Trip local indication to simplify identification of a tripped circuit breaker. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EGB34060SA delivers the reliability and precision required for overload, short-circuit, and remotely initiated circuit interruption in commercial electrical distribution systems.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52605196140842,"sku":"EGB34060SA","price":1925.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_d13d313a-10ed-4718-ac41-c19798343a2b.webp?v=1789421305","url":"https:\/\/iqelectro.com\/products\/square-d-egb34060sa-60-ampere-3-pole-480y-277-volt-molded-case-circuit-breaker","provider":"IQElectro","version":"1.0","type":"link"}