{"product_id":"viconics-vt7200f5031b-bacnet-vav-zone-controller-with-0-10-vdc-outputs","title":"Viconics VT7200F5031B BACnet VAV Zone Controller with 0–10 VDC Outputs","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eViconics VT7200F5031B is a BACnet MS\/TP zone controller designed for pressure-dependent VAV applications. It provides two proportional 0–10 VDC outputs for heating and cooling control, along with configurable inputs for occupancy, service, filter, and changeover functions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.941%; height: 550.626px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eViconics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eVT7200F5031B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eBuilding Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eVAV Zone Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eVT7200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eBACnet VAV Zone Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003ePressure-Dependent VAV Zone Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eBACnet MS\/TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e19–30 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e2 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e2 × 0–10 VDC analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eAnalog Output Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e2 kΩ minimum impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eProportional-Integral (PI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eAuxiliary Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e2 digital inputs, 1 universal input, 1 remote sensor input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eUniversal Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eDry contact or 10K Type 2 thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eTwo-line backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e±0.5°C (±0.9°F) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eHeating Setpoint Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e40–90°F (4.5–32°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eCooling Setpoint Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e54–100°F (12–37.7°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e0–50°C (32–122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e0–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eFlame-retardant plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eStandard vertical, 2 × 4 in box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003eApprox. 4.94 × 3.38 × 1.13 in (12.5 × 8.6 × 2.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 21.5938px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 21.5938px;\"\u003eUL, cUL, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.0535%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5276%; height: 19.5938px;\"\u003e 0.75 lb \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About VT7200F5031B\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe VT7200F5031B is part of the Viconics VT7200 Series of digital zone controllers for commercial HVAC systems. It operates from 19–30 VAC and uses BACnet MS\/TP communication for integration with compatible building automation systems. The controller uses proportional-integral control and provides two analog 0–10 VDC outputs with direct or reverse-acting configuration. Three configurable inputs can support functions such as night setback, motion detection, filter alarm, door\/window status, or heat\/cool changeover.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MS\/TP Communication: Provides open-protocol communication with compatible building automation systems.\u003c\/li\u003e\n\u003cli\u003eVAV Zone Control: Designed for pressure-dependent variable air volume terminal applications.\u003c\/li\u003e\n\u003cli\u003eTwo Analog Outputs: Provides two proportional 0–10 VDC outputs for heating and cooling control.\u003c\/li\u003e\n\u003cli\u003ePI Control: Uses proportional-integral control for stable zone temperature regulation.\u003c\/li\u003e\n\u003cli\u003eConfigurable Inputs: Supports occupancy, setback, service, filter, motion, and changeover functions.\u003c\/li\u003e\n\u003cli\u003eRemote Sensor Support: Accepts a compatible 10K Type 2 thermistor remote temperature sensor.\u003c\/li\u003e\n\u003cli\u003eBacklit LCD: Provides a two-line display for temperature and controller status information.\u003c\/li\u003e\n\u003cli\u003eLockable Keypad: Supports keypad lockout to restrict unauthorized adjustment of settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe VT7200F5031B delivers the control flexibility and communication capability required for reliable VAV zone HVAC applications.\u003c\/span\u003e\u003c\/p\u003e","brand":"Viconics","offers":[{"title":"Default Title","offer_id":52568639275306,"sku":"VT7200F5031B","price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/d25284ee5c834c62b7c5d72dd7be518b.jpg?v=1789119777","url":"https:\/\/iqelectro.com\/products\/viconics-vt7200f5031b-bacnet-vav-zone-controller-with-0-10-vdc-outputs","provider":"IQElectro","version":"1.0","type":"link"}