{"product_id":"wacker-neuson-5000183512-2-x-16-inch-supply-duct-adapter-for-hi400hdd-air-heater","title":"Wacker Neuson 5000183512 2 x 16-Inch Supply Duct Adapter for HI400HDD Air Heater","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Wacker Neuson 5000183512 is a 2 × 16-inch supply duct adapter designed for compatible Wacker Neuson indirect-fired air heaters. It divides heated supply airflow into two 16-inch duct connections, allowing warm air to be distributed to separate areas through flexible ducting.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.47px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eWacker Neuson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eHeater Parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003e5000183512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eSupply Duct Adapters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eSupply Air Duct Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eDuct Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003e2 × 16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutlet Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003e16 in each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eAirflow Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eHeated Supply Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 39.1875px;\"\u003e\u003cstrong\u003eCompatible Equipment Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 39.1875px;\"\u003eIndirect-Fired Air Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eWacker Neuson HI400HDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eHeater Supply-Air Outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eDuct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eFlexible Heated-Air Supply Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003eSplit and distribute heater supply airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 39.1875px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 39.1875px;\"\u003eConstruction Heating \/ Temporary Heating \/ Drying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.8%; height: 19.5938px;\"\u003e\u003cstrong\u003eLegacy Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7368%; height: 19.5938px;\"\u003e0183512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e5000183512\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 5000183512 is a Wacker Neuson supply-air duct adapter documented for the HI400HDD indirect-fired air heater. It uses a dual-outlet configuration with two 16-inch connections for attaching compatible flexible supply ducts. The adapter mounts at the heater's supply-air outlet and provides a mechanical transition between the heater housing and the downstream duct system. It is intended for temporary heating applications where heated air must be routed away from the heater to construction areas, enclosed workspaces, drying zones, or other conditioned spaces.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual 16-Inch Outlets: Provides two connections for 16-inch supply ducts.\u003c\/li\u003e\n\u003cli\u003eHI400HDD Compatibility: Documented for the Wacker Neuson HI400HDD air heater.\u003c\/li\u003e\n\u003cli\u003eSupply-Air Application: Routes heated discharge air into flexible ducting.\u003c\/li\u003e\n\u003cli\u003eSplit Air Distribution: Allows one heater outlet to supply two separate duct runs.\u003c\/li\u003e\n\u003cli\u003eDirect-Mount Design: Installs at the heater's supply-air discharge opening.\u003c\/li\u003e\n\u003cli\u003eFlexible Duct Support: Designed for use with compatible 16-inch heated-air ducting.\u003c\/li\u003e\n\u003cli\u003eService Replacement: Replaces the corresponding original duct adapter when damaged or missing.\u003c\/li\u003e\n\u003cli\u003eHeater Accessory Construction: Built for portable industrial and construction heating applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 5000183512 delivers the reliability and precision required for distributing heated supply air from compatible Wacker Neuson indirect-fired heaters.\u003c\/p\u003e","brand":"Wacker Neuson","offers":[{"title":"Default Title","offer_id":52554963976490,"sku":"5000183512","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_2cb899ae-dc38-404b-aece-6aa4c50a7e97.webp?v=1788979659","url":"https:\/\/iqelectro.com\/products\/wacker-neuson-5000183512-2-x-16-inch-supply-duct-adapter-for-hi400hdd-air-heater","provider":"IQElectro","version":"1.0","type":"link"}