{"product_id":"westinghouse-kb3200-200a-3-pole-600v-molded-case-circuit-breaker","title":"Westinghouse KB3200 200A 3-Pole 600V Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"429\"\u003eThe Westinghouse KB3200 is a 200 Amp, 3-pole molded case circuit breaker designed for industrial and commercial electrical systems. It provides reliable protection for circuits operating at 240–600 VAC or 250 VDC. This breaker fits Westinghouse CDP panelboards, Eaton Series C panelboards, switchboards, and motor control centers.\u003c\/p\u003e\n\u003ch2 data-start=\"431\" data-end=\"457\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable height=\"434\" style=\"width: 90.7609%; height: 340.988px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eWestinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eKB3200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eKB Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e200 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e240VAC, 480VAC, 600VAC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eThree-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eLong-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eFixed Thermal, Adjustable Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.3px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.4875px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e25kA @ 240VAC, 22kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e3 AWG – 350 kcmil (Al\/Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eOptional Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eNEMA AB-1, UL 489, CSA C22.2 No. 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eUL, CSA, HACR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eConstruction Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eHACR Rated, Interchangeable Trip, Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e12 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eKB3200\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"458\" data-end=\"1028\"\u003eThe KB3200 is part of Westinghouse’s KB series of molded case breakers, engineered for high-current protection. It features bolt-on mounting with lug terminals for secure installation. The breaker employs a thermal-magnetic trip mechanism with long-time and instantaneous functionality. Optional features include shunt trip, auxiliary switch, undervoltage release, and alarm switch to meet diverse application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1052\" data-end=\"1841\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"997\" data-end=\"1535\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1008\" data-end=\"1696\"\u003e\n\u003cli data-section-id=\"1p6k8jb\" data-start=\"1008\" data-end=\"1082\"\u003e\n\u003cstrong data-start=\"1010\" data-end=\"1020\"\u003eSeries\u003c\/strong\u003e: KB Series molded case breaker for industrial applications.\u003c\/li\u003e\n\u003cli data-section-id=\"6hqsxa\" data-start=\"1083\" data-end=\"1154\"\u003e\n\u003cstrong data-start=\"1085\" data-end=\"1094\"\u003ePoles\u003c\/strong\u003e: 3-pole configuration for three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-section-id=\"6u6jer\" data-start=\"1155\" data-end=\"1212\"\u003e\n\u003cstrong data-start=\"1157\" data-end=\"1175\"\u003eCurrent Rating\u003c\/strong\u003e: 200 Amp continuous load capacity.\u003c\/li\u003e\n\u003cli data-section-id=\"11qx38d\" data-start=\"1213\" data-end=\"1279\"\u003e\n\u003cstrong data-start=\"1215\" data-end=\"1233\"\u003eVoltage Rating\u003c\/strong\u003e: 240VAC, 480VAC, 600VAC, 250VDC compatible.\u003c\/li\u003e\n\u003cli data-section-id=\"15ie6oe\" data-start=\"1280\" data-end=\"1335\"\u003e\n\u003cstrong data-start=\"1282\" data-end=\"1300\"\u003eMounting Style\u003c\/strong\u003e: Bolt-on for panel installation.\u003c\/li\u003e\n\u003cli data-section-id=\"1r2b2rb\" data-start=\"1336\" data-end=\"1419\"\u003e\n\u003cstrong data-start=\"1338\" data-end=\"1356\"\u003eTrip Mechanism\u003c\/strong\u003e: Thermal-magnetic for overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-section-id=\"1vawxlb\" data-start=\"1420\" data-end=\"1501\"\u003e\n\u003cstrong data-start=\"1422\" data-end=\"1439\"\u003eTrip Function\u003c\/strong\u003e: Long-time and instantaneous (LI) with adjustable magnetic.\u003c\/li\u003e\n\u003cli data-section-id=\"l3l8bb\" data-start=\"1502\" data-end=\"1601\"\u003e\n\u003cstrong data-start=\"1504\" data-end=\"1521\"\u003eCompatibility\u003c\/strong\u003e: Fits Westinghouse CDP panels, Eaton Series C panels, switchboards, and MCCs.\u003c\/li\u003e\n\u003cli data-section-id=\"4sujmi\" data-start=\"1602\" data-end=\"1696\"\u003e\n\u003cstrong data-start=\"1604\" data-end=\"1620\"\u003eConstruction\u003c\/strong\u003e: HACR-rated molded case with interchangeable trip and panel mount design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1698\" data-end=\"1804\"\u003eThe KB3200 delivers the reliability and precision required for high-current industrial circuit protection.\u003c\/p\u003e","brand":"Westinghouse","offers":[{"title":"Default Title","offer_id":51444967276842,"sku":"KB3200","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_53f638f4-667e-4339-92a9-9343925e244a.webp?v=1776689339","url":"https:\/\/iqelectro.com\/products\/westinghouse-kb3200-200a-3-pole-600v-molded-case-circuit-breaker","provider":"IQElectro","version":"1.0","type":"link"}