{"product_id":"white-rodgers-50m61-495-02-integrated-furnace-control-board","title":"White-Rodgers 50M61-495-02 Integrated Furnace Control Board","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe White-Rodgers 50M61-495-02 is an integrated furnace control board designed to manage ignition, blower operation, and safety functions in compatible gas furnaces. It supports two-stage heating and variable-speed blower applications while providing diagnostic functions for furnace troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003col start=\"2\" data-start=\"283\" data-end=\"303\"\u003e\u003c\/ol\u003e\n\u003col start=\"2\" data-start=\"303\" data-end=\"323\"\u003e\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003col start=\"2\" data-start=\"336\" data-end=\"356\"\u003e\u003c\/ol\u003e\n\u003col start=\"2\" data-start=\"366\" data-end=\"386\"\u003e\u003c\/ol\u003e\n\u003col start=\"2\" data-start=\"306\" data-end=\"326\"\u003e\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWhite-Rodgers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFurnace Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50M61-495-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControl Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eControl Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Furnace Control (IFC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHeating Stages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-stage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlower Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVariable-speed compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFurnace Efficiency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80% and 90% efficient configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFurnace Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUpflow and horizontal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eControl Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIgnition, blower, sensor, and safety monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDiagnostic Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFurnace troubleshooting diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRelated Part Numbers\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eD341418P01, D341418P02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eReplaces\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50M51-495, 50M61-495\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.00 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About 50M61-495-02\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"305\" data-end=\"863\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cspan\u003eThe 50M61-495-02 is an OEM replacement control board associated with D341418P01 and D341418P02 furnace control assemblies. It is designed for compatible 80% and 90% efficient upflow and horizontal furnace configurations. The board interfaces with furnace sensors and safety switches while coordinating the ignition sequence and blower motor operation. It replaces earlier White-Rodgers control models including the 50M51-495 and 50M61-495 in specified furnace applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003col start=\"3\" data-start=\"865\" data-end=\"880\"\u003e\u003c\/ol\u003e\n\u003col start=\"3\" data-start=\"933\" data-end=\"948\"\u003e\u003c\/ol\u003e\n\u003col start=\"3\" data-start=\"715\" data-end=\"730\"\u003e\u003c\/ol\u003e\n\u003col start=\"3\" data-start=\"871\" data-end=\"886\"\u003e\u003c\/ol\u003e\n\u003col start=\"3\" data-start=\"811\" data-end=\"826\"\u003e\u003c\/ol\u003e\n\u003col start=\"3\" data-start=\"849\" data-end=\"864\"\u003e\u003c\/ol\u003e\n\u003cp dir=\"auto\" data-start=\"456\" data-end=\"1011\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"884\" data-end=\"1622\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"920\" data-end=\"1764\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"920\" data-end=\"1764\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"888\" data-end=\"1601\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"732\" data-end=\"1440\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"761\" data-end=\"1481\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"799\" data-end=\"1550\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"882\" data-end=\"1714\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated Furnace Control: Combines ignition, blower, and safety control functions on one furnace control board.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-Stage Heating: Supports two-stage heating operation for controlled furnace performance.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVariable-Speed Blower Control: Provides control of compatible variable-speed blower motors for regulated airflow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIgnition Management: Coordinates the ignition sequence during the furnace heating cycle.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBlower Operation: Controls blower motor startup and shutdown according to the operating sequence.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafety Monitoring: Monitors connected sensors and safety switches during furnace operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDiagnostic Functions: Provides diagnostic capabilities for identifying furnace operating faults.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement Compatibility: Replaces specified earlier White-Rodgers 50M51-495 and 50M61-495 control boards.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe 50M61-495-02 delivers the reliability and precision required for furnace ignition, blower control, safety monitoring, and diagnostic operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"884\" data-end=\"1622\"\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"White-Rodgers","offers":[{"title":"Default Title","offer_id":52793463439658,"sku":"50M61-495-02","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/images_7720f34b-2486-46ba-b780-0c16a50eaeb3.jpg?v=1790701758","url":"https:\/\/iqelectro.com\/products\/white-rodgers-50m61-495-02-integrated-furnace-control-board","provider":"IQElectro","version":"1.0","type":"link"}