104-C09D22 | Allen-Bradley Reversing Contactor
104-C09D22 | Allen-Bradley Reversing Contactor
104-C09D22 | Allen-Bradley Reversing Contactor
    104-C09D22 | Allen-Bradley Reversing Contactor
104-C09D22 | Allen-Bradley Reversing Contactor

104-C09D22 | Allen-Bradley Reversing Contactor

Part #: 104-C09D22 Manufactured by: Allen-Bradley
Regular price
$202.00
Sale price
$202.00
Regular price
1 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The 104-C09D22 is a reversing contactor built to the IEC standard. With a 9 Amp rating and a three-pole design, it operate...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: 104-C09D22
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: 104-C09D22

Description / Specifications

Description 

The 104-C09D22 is a reversing contactor conforming to the IEC standard. It is rated for 9 Amps and features a 3-pole configuration. The contactor operates with a 120 Volt AC coil. It includes 1 normally open and 1 normally closed auxiliary contacts. 


Technical Specifications 

Part # 

104-C09D22 

Category 

Contactors & Starters 

Subcategory 

Contactor 

Voltage type for actuating 

AC 

Rated control supply voltage at AC 50 Hz 

110 V 

Rated control supply voltage at AC 60 Hz 

120 V 

Current (Ie), max 

97 A 

Switching frequency, max 

250 ops/h 

Main current circuit resistance 

2.7 mOhm 

Cross section per UL/CSA 

16 AWG 

Rated operational current for contactor at elevator duty (UL/CSA) 

7.8 A @ 200V 

Rated operational power for contactor at elevator duty (UL/CSA) 

5 Hp @ 575V 

Rated isolation voltage (Ui) 

690V @ IEC 

Rated voltage (Ue) 

690V @ AC, 50/60 Hz 

Rated operational power for contactor at wye-delta 

5 Hp @ 230V, 60 Hz 

Rated filament current 

12 A @ 230/240V, AC-5b 

Power dissipation 

0.66 W @ 400V, AC-3, Ie 

Coil terminal conductor cross section 

1…4 mm^2 @ 2 conductor 

Rated current (enclosed) 

9.8 A @ 115V, 1-phase per UL/CSA 

Rated power (enclosed) 

7.5 Hp @ 575V, 3-phase per UL/CSA 

Coil consumption pick-up (avg/peak) 

14/22 W @ DC (electronic-EA) 

General purpose current (enclosed) 

25 A per UL/CSA 

Capacitance, max 

500 µF @ short-circuit current of 20 kA 

Switching of low inductive loads 

32 A @ 440V, AC-7a per IEC 61095 (50 Hz) 

Operating limits, pick-up 

(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz 

Switching of motor load 

9 A @ 400V, AC-7b per IEC 61095 (50 Hz) 

Short time withstand (Icw) 

170 A for 10 s, 60 °C 

Coil consumption, hold-in 

9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz 

Coil consumption, pick-up 

75VA @ 50 Hz, 60 Hz, 50/60 Hz 

Operating time 

15…30 ms @ AC closing delay 

Total power dissipation 

DC control (electronic): 2.4 W @ 400V, AC-3, Ie 

Operating limits, dropout 

(0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz 

Switching of lamps 

Gas discharge lamps, open: 22.5 A @ 40 °C (104 °F), AC-5a 

Switching of hermetically sealed cooling compressor motors 

8 A @ 690V, AC-8a (manual reset of overload release (50 Hz)) 

Coil insulation class 

Class F per IEC 60085, UL Class 105 

Rating for switching AC motors 

3-poles: 7 1/2 Hp @575V (AC-2, AC-3, AC-4), 3-phase (60 Hz) 

BS88 fuses current rating 

Type 2 (per IEC 60947-4-1): 20 A @ 415V, 65 kA available fault current 

UL class K5 and RK5 fuses rating 

35 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 

UL class CC and CSA HRCI-MISC fuses rating 

20 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 

UL inverse-time circuit breaker 

30 A @ 600Y/347V, 25 kA available fault current per UL 508 and CSA 22.2 No. 14 

Rated operational current (Ie) 

9 A @ 575V, 3-phase per UL/CSA 

Rated operational power (Pe) 

7.5 kW @ 690V, Star-Delta starting (50 Hz) 

DIN fuses (gG, gL) current rating 

Type 2 (per IEC 60947-4-1): 25 A @ 690V, 50 kA available fault current 

UL class J and CSA HRCI-J fuses rating 

20 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 

Switching of power transformers 

Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30) 

Switching of 3-phase Capacitors 

Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH) 

Switching of DC loads 

3-Poles in series: 6 A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C) 

Contacts 

3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block 

Function 

Reversing contactor 

Rated impulse voltage withstand (Uimp) 

6 kV 

Conventional coil type 

Yes 

Electronic-EI coil type 

Yes 

Rated coil frequency 

AC 50/60 Hz, DC 

 

Information About 104-C09D22

The 104-C09D22 is a reversing contactor adhering to the IEC standard. It operates at a current rating of 9 Amps and features a three-pole configuration. The contactor's actuation is through a 120 Volt AC coil. Additionally, it includes one normally open and one normally closed auxiliary contact for enhanced functionality and control within electrical circuits. 

Manufacturer information

Allen-Bradley, a brand of Rockwell Automation, specializes in manufacturing industrial automation equipment. The product range includes programmable logic controllers (PLCs), motion control systems, safety devices, motor control equipment, automation software, and HMI panels. Allen-Bradley products are known for their reliability and integration with other systems.

IQElectro is not an authorized distributor.
QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The 104-C09D22 is a reversing contactor conforming to the IEC standard. It is rated for 9 Amps and features a 3-pole configuration. The contactor operates with a 120 Volt AC coil. It includes 1 normally open and 1 normally closed auxiliary contacts. 


Technical Specifications 

Part # 

104-C09D22 

Category 

Contactors & Starters 

Subcategory 

Contactor 

Voltage type for actuating 

AC 

Rated control supply voltage at AC 50 Hz 

110 V 

Rated control supply voltage at AC 60 Hz 

120 V 

Current (Ie), max 

97 A 

Switching frequency, max 

250 ops/h 

Main current circuit resistance 

2.7 mOhm 

Cross section per UL/CSA 

16 AWG 

Rated operational current for contactor at elevator duty (UL/CSA) 

7.8 A @ 200V 

Rated operational power for contactor at elevator duty (UL/CSA) 

5 Hp @ 575V 

Rated isolation voltage (Ui) 

690V @ IEC 

Rated voltage (Ue) 

690V @ AC, 50/60 Hz 

Rated operational power for contactor at wye-delta 

5 Hp @ 230V, 60 Hz 

Rated filament current 

12 A @ 230/240V, AC-5b 

Power dissipation 

0.66 W @ 400V, AC-3, Ie 

Coil terminal conductor cross section 

1…4 mm^2 @ 2 conductor 

Rated current (enclosed) 

9.8 A @ 115V, 1-phase per UL/CSA 

Rated power (enclosed) 

7.5 Hp @ 575V, 3-phase per UL/CSA 

Coil consumption pick-up (avg/peak) 

14/22 W @ DC (electronic-EA) 

General purpose current (enclosed) 

25 A per UL/CSA 

Capacitance, max 

500 µF @ short-circuit current of 20 kA 

Switching of low inductive loads 

32 A @ 440V, AC-7a per IEC 61095 (50 Hz) 

Operating limits, pick-up 

(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz 

Switching of motor load 

9 A @ 400V, AC-7b per IEC 61095 (50 Hz) 

Short time withstand (Icw) 

170 A for 10 s, 60 °C 

Coil consumption, hold-in 

9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz 

Coil consumption, pick-up 

75VA @ 50 Hz, 60 Hz, 50/60 Hz 

Operating time 

15…30 ms @ AC closing delay 

Total power dissipation 

DC control (electronic): 2.4 W @ 400V, AC-3, Ie 

Operating limits, dropout 

(0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz 

Switching of lamps 

Gas discharge lamps, open: 22.5 A @ 40 °C (104 °F), AC-5a 

Switching of hermetically sealed cooling compressor motors 

8 A @ 690V, AC-8a (manual reset of overload release (50 Hz)) 

Coil insulation class 

Class F per IEC 60085, UL Class 105 

Rating for switching AC motors 

3-poles: 7 1/2 Hp @575V (AC-2, AC-3, AC-4), 3-phase (60 Hz) 

BS88 fuses current rating 

Type 2 (per IEC 60947-4-1): 20 A @ 415V, 65 kA available fault current 

UL class K5 and RK5 fuses rating 

35 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 

UL class CC and CSA HRCI-MISC fuses rating 

20 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 

UL inverse-time circuit breaker 

30 A @ 600Y/347V, 25 kA available fault current per UL 508 and CSA 22.2 No. 14 

Rated operational current (Ie) 

9 A @ 575V, 3-phase per UL/CSA 

Rated operational power (Pe) 

7.5 kW @ 690V, Star-Delta starting (50 Hz) 

DIN fuses (gG, gL) current rating 

Type 2 (per IEC 60947-4-1): 25 A @ 690V, 50 kA available fault current 

UL class J and CSA HRCI-J fuses rating 

20 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 

Switching of power transformers 

Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30) 

Switching of 3-phase Capacitors 

Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH) 

Switching of DC loads 

3-Poles in series: 6 A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C) 

Contacts 

3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block 

Function 

Reversing contactor 

Rated impulse voltage withstand (Uimp) 

6 kV 

Conventional coil type 

Yes 

Electronic-EI coil type 

Yes 

Rated coil frequency 

AC 50/60 Hz, DC 

 

Information About 104-C09D22

The 104-C09D22 is a reversing contactor adhering to the IEC standard. It operates at a current rating of 9 Amps and features a three-pole configuration. The contactor's actuation is through a 120 Volt AC coil. Additionally, it includes one normally open and one normally closed auxiliary contact for enhanced functionality and control within electrical circuits. 

Manufacturer information

Allen-Bradley, a brand of Rockwell Automation, specializes in manufacturing industrial automation equipment. The product range includes programmable logic controllers (PLCs), motion control systems, safety devices, motor control equipment, automation software, and HMI panels. Allen-Bradley products are known for their reliability and integration with other systems.

Check Out These Related Products

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)