Part #: 140-CMN-9000 Manufactured by: Allen-Bradley
Regular price
$798.00
Sale price
$798.00
Regular price
3 in Stock
Condition: New – Open box
Shipping calculated at checkout.
Product Overview
Allen Bradley 140-CMN-9000 Motor Protection Circuit Breaker, Standard Magnetic Trip, Adjustable Thermal Current Range 63.0...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Contact Us!

Talk to a real expert.

Mon–Sat, 7:00 AM – 12:00 PM (EST)
warranty
IQElectro 2-Year Warranty
Warranty for Product #: 140-CMN-9000
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: 140-CMN-9000

Description / Specifications

Description 

The Allen-Bradley 140-CMN-9000 is a motor protection circuit breaker designed to safeguard three-phase systems with adjustable overload and magnetic trip characteristics. It provides a 63–90 amp adjustable range and supports 480 V operation for dependable protection in industrial applications.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Allen-Bradley
Category Circuit Protection
Part Number 140-CMN-9000
Subcategory Motor Protection Circuit Breaker
Voltage Rating 480 V
Amperage Range 63–90 A adjustable
Poles 3
Phase 3 phase
Trip Type Standard magnetic trip
Short-Circuit Rating 35 kA at 480 V
Termination Style Feed-through
Application Motor protection and feeder protection
Construction Industrial-grade breaker housing
Weight 4.5 lb

 

 

Information About 140-CMN-9000

The 140-CMN-9000 is part of Allen-Bradley’s Bulletin 140 motor protection lineup engineered for reliable safeguarding of motors and feeder circuits. It features a three-pole configuration with a 63–90 A adjustable setting range, enabling accurate coordination with motor full-load currents. The breaker provides a standard magnetic trip and a high short-circuit interrupt rating of 35 kA at 480 V, ensuring strong fault-clearing capability in demanding environments. Its feed-through construction and robust mechanical design support seamless integration into control panels and motor control centers for consistent system protection.

Key Features:

  • 63–90 A Adjustable Range: Allows precise alignment of motor protection settings with application requirements.
  • Three-Pole Construction: Supports three-phase circuit protection for motors and feeder circuits.
  • 480 V Operating Voltage: Compatible with common industrial power systems requiring high-voltage protection.
  • 35 kA Short-Circuit Rating: Provides strong fault-clearing performance for enhanced electrical safety.
  • Standard Magnetic Trip: Ensures fast response to short-circuit conditions to minimize equipment damage.
  • Motor Circuit Protector Design: Specifically engineered for motor overload and short-circuit protection.
  • Feed-Through Termination: Facilitates straightforward installation in panel assemblies and MCCs.
  • Durable Industrial Build: Constructed for long service life under repetitive switching and fault conditions.

The 140-CMN-9000 delivers the reliability and precision required for safeguarding motors and three-phase circuits in industrial installations.

Frequently Asked Questions about 140-CMN-9000
Question: What is the 140-CMN-9000 used for?
Date Update:17/06/2025
Answer:

The 140-CMN-9000 is most likely a communication adapter or interface module, used to network Allen-Bradley 140M motor protection devices or MCCs to a control or monitoring system, potentially via:

  • DeviceNet
  • ControlNet
  • Or a proprietary serial protocol

It serves as a data gateway, allowing status monitoring, fault indication, and parameter adjustments over an industrial network.

Question: What products is the 140-CMN-9000 compatible with?
Date Update:17/06/2025
Answer:

Based on naming conventions and limited available reference:

  • Likely used with 140M-C or 140M-D series motor circuit protectors
  • May also interface with Rockwell MCCs or Smart Motor Controllers (SMCs)
  • Communication-enabled for integration into PLC or SCADA systems

Due to age, it’s best to verify via the original MCC bill of materials or panel drawings.

Question: Does the 140-CMN-9000 support EtherNet/IP or DeviceNet?
Date Update:17/06/2025
Answer:

It may support DeviceNet or a Rockwell proprietary protocol, depending on the vintage. It is unlikely to support EtherNet/IP natively.

If you’re looking to migrate to modern networking, consider upgrading to:

  • E300 Modular Motor Protection Relay
  • Or a full MCC modernization package from Rockwell
Question: Can this module support diagnostics like overload or phase loss?
Date Update:17/06/2025
Answer:

Depending on the connected devices, the 140-CMN-9000 might have supported:

  • Basic fault codes (trip status, reset)
  • Motor run feedback
  • But not advanced diagnostics like energy monitoring, fault waveforms, or predictive alerts

For that level of detail, consider migrating to an E300 relay or smart MCC solution.

Question: How do I determine if the 140-CMN-9000 is still functional?
Date Update:17/06/2025
Answer:

Yes, by:

  • Replacing the 140-CMN-9000 with a modern EtherNet/IP-compatible device like the E300 or E200
  • Installing an EtherNet/IP to DeviceNet bridge, if intermediate migration is preferred
  • Using distributed I/O blocks (e.g., ArmorBlock) for modular upgrades

This allows seamless PLC integration without completely rewiring the MCC.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Allen-Bradley 140-CMN-9000 is a motor protection circuit breaker designed to safeguard three-phase systems with adjustable overload and magnetic trip characteristics. It provides a 63–90 amp adjustable range and supports 480 V operation for dependable protection in industrial applications.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Allen-Bradley
Category Circuit Protection
Part Number 140-CMN-9000
Subcategory Motor Protection Circuit Breaker
Voltage Rating 480 V
Amperage Range 63–90 A adjustable
Poles 3
Phase 3 phase
Trip Type Standard magnetic trip
Short-Circuit Rating 35 kA at 480 V
Termination Style Feed-through
Application Motor protection and feeder protection
Construction Industrial-grade breaker housing
Weight 4.5 lb

 

 

Information About 140-CMN-9000

The 140-CMN-9000 is part of Allen-Bradley’s Bulletin 140 motor protection lineup engineered for reliable safeguarding of motors and feeder circuits. It features a three-pole configuration with a 63–90 A adjustable setting range, enabling accurate coordination with motor full-load currents. The breaker provides a standard magnetic trip and a high short-circuit interrupt rating of 35 kA at 480 V, ensuring strong fault-clearing capability in demanding environments. Its feed-through construction and robust mechanical design support seamless integration into control panels and motor control centers for consistent system protection.

Key Features:

  • 63–90 A Adjustable Range: Allows precise alignment of motor protection settings with application requirements.
  • Three-Pole Construction: Supports three-phase circuit protection for motors and feeder circuits.
  • 480 V Operating Voltage: Compatible with common industrial power systems requiring high-voltage protection.
  • 35 kA Short-Circuit Rating: Provides strong fault-clearing performance for enhanced electrical safety.
  • Standard Magnetic Trip: Ensures fast response to short-circuit conditions to minimize equipment damage.
  • Motor Circuit Protector Design: Specifically engineered for motor overload and short-circuit protection.
  • Feed-Through Termination: Facilitates straightforward installation in panel assemblies and MCCs.
  • Durable Industrial Build: Constructed for long service life under repetitive switching and fault conditions.

The 140-CMN-9000 delivers the reliability and precision required for safeguarding motors and three-phase circuits in industrial installations.

Check Out These Related Products