Part #: 140G-H2C3-C60 Manufactured by: Allen-Bradley
Regular price
$559.00
Sale price
$559.00
Regular price
1 in Stock
Condition: New – Open box
Shipping calculated at checkout.
Product Overview
The Allen-Bradley 140G-H2C3-C60 Molded Case Circuit Breaker has a H Frame and 125 Amps. It also has a 25 kA Interrupting R...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Contact Us!

Talk to a real expert.

Mon–Sat, 7:00 AM – 12:00 PM (EST)
warranty
IQElectro 2-Year Warranty
Warranty for Product #: 140G-H2C3-C60
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: 140G-H2C3-C60

Description / Specifications

Description 

The Allen-Bradley 140G-H2C3-C60 is a molded case circuit breaker designed with fixed thermal and magnetic trip elements for dependable overcurrent and short-circuit protection. This 3-pole H-frame breaker provides a 60A thermal trip rating and a 600A magnetic trip threshold, supporting stable operation in industrial power systems. Built for an 80% continuous load rating, it delivers robust protection in compact control panel installations.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Allen-Bradley
Category Contactors & Starters
Part Number 140G-H2C3-C60
Subcategory Molded Case Circuit Breaker
Frame Size H Frame
Trip Type Fixed Thermal / Fixed Magnetic
Thermal Trip Rating 60 A
Magnetic Trip Rating 600 A
Number of Poles 3
Interrupting Rating 25 kA
Rated Insulation Voltage 1000 V
Rated Impulse Withstand Voltage 8 kV
Continuous Load Rating 80%
Mechanical Life 240 operations/hr
Electrical Life 120 operations/hr
Enclosure Type Molded Case
Applications Main/branch circuit protection, industrial control panels

 

 

Information About 140G-H2C3-C60

The 140G-H2C3-C60 is part of the Allen-Bradley Bulletin 140G molded case circuit breaker family, engineered to safeguard industrial circuits with fixed thermal and magnetic trip characteristics. Its H-frame construction and 3-pole configuration provide reliable protection for equipment operating across standard industrial voltage systems. Designed with a 60A thermal and 600A magnetic trip range, the breaker ensures timely response to overload and short-circuit events. With a durable molded case, arc-extinguishing chamber, and corrosion-resistant terminals, it integrates seamlessly into machinery, distribution panels, and motor control applications where compact, reliable protection is required.

Key Features:

  • Fixed thermal/magnetic trip: 60A thermal and 600A magnetic thresholds for dependable overload and fault protection.
  • H-frame molded case design: Supports industrial applications requiring compact yet robust circuit protection.
  • High interrupting capacity: Rated for demanding AC/DC fault conditions across multiple voltage classes.
  • 3-pole configuration: Suitable for industrial three-phase power distribution systems.
  • Manual reset mechanism: Ensures safe restoration of power following a fault event.
  • Arc-chamber design: Enhances interruption speed and reduces wear on internal contacts.
  • Industrial durability: Glass-fiber housing and corrosion-resistant terminals increase service life.
  • Panel-space optimized: Compact dimensions support dense control panel configurations.

The 140G-H2C3-C60 delivers the reliability and precision required for protecting industrial power distribution and control equipment.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Allen-Bradley 140G-H2C3-C60 is a molded case circuit breaker designed with fixed thermal and magnetic trip elements for dependable overcurrent and short-circuit protection. This 3-pole H-frame breaker provides a 60A thermal trip rating and a 600A magnetic trip threshold, supporting stable operation in industrial power systems. Built for an 80% continuous load rating, it delivers robust protection in compact control panel installations.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Allen-Bradley
Category Contactors & Starters
Part Number 140G-H2C3-C60
Subcategory Molded Case Circuit Breaker
Frame Size H Frame
Trip Type Fixed Thermal / Fixed Magnetic
Thermal Trip Rating 60 A
Magnetic Trip Rating 600 A
Number of Poles 3
Interrupting Rating 25 kA
Rated Insulation Voltage 1000 V
Rated Impulse Withstand Voltage 8 kV
Continuous Load Rating 80%
Mechanical Life 240 operations/hr
Electrical Life 120 operations/hr
Enclosure Type Molded Case
Applications Main/branch circuit protection, industrial control panels

 

 

Information About 140G-H2C3-C60

The 140G-H2C3-C60 is part of the Allen-Bradley Bulletin 140G molded case circuit breaker family, engineered to safeguard industrial circuits with fixed thermal and magnetic trip characteristics. Its H-frame construction and 3-pole configuration provide reliable protection for equipment operating across standard industrial voltage systems. Designed with a 60A thermal and 600A magnetic trip range, the breaker ensures timely response to overload and short-circuit events. With a durable molded case, arc-extinguishing chamber, and corrosion-resistant terminals, it integrates seamlessly into machinery, distribution panels, and motor control applications where compact, reliable protection is required.

Key Features:

  • Fixed thermal/magnetic trip: 60A thermal and 600A magnetic thresholds for dependable overload and fault protection.
  • H-frame molded case design: Supports industrial applications requiring compact yet robust circuit protection.
  • High interrupting capacity: Rated for demanding AC/DC fault conditions across multiple voltage classes.
  • 3-pole configuration: Suitable for industrial three-phase power distribution systems.
  • Manual reset mechanism: Ensures safe restoration of power following a fault event.
  • Arc-chamber design: Enhances interruption speed and reduces wear on internal contacts.
  • Industrial durability: Glass-fiber housing and corrosion-resistant terminals increase service life.
  • Panel-space optimized: Compact dimensions support dense control panel configurations.

The 140G-H2C3-C60 delivers the reliability and precision required for protecting industrial power distribution and control equipment.