Part #: 140M-D8E-C20 Manufactured by: Allen-Bradley
Regular price
$199.00
Sale price
$199.00
Regular price
5 in Stock
Condition: New – Open box
Shipping calculated at checkout.
Product Overview
Allen Bradley 140M-D8E-C20 Motor Protection Circuit Breaker (MPCB), Supply Voltage 480Y/277V AC 50/60Hz, Standard Magnetic...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: 140M-D8E-C20
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: 140M-D8E-C20

Description / Specifications

Description 

The Allen-Bradley 140M-D8E-C20 is a high-performance motor protection circuit breaker designed for thermal-magnetic protection in industrial motor circuits. It supports a 14.5–20 A adjustable trip range within a D-frame design and is rated for short-circuit interruption up to 100 kAIC.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Allen-Bradley
Category Circuit Protection
Part Number 140M-D8E-C20
Subcategory Motor Protection Circuit Breakers
Amperage Rating 14.5–20 A (Thermal Trip Range)
Frame D Frame
Trip Type Thermal Magnetic
Interrupt Rating 100 kAIC
Voltage Rating 200–690 V
Motor Power Rating 5.5 kW / 10 kW
Circuit Breaker Type Motor Protection Circuit Breaker
Application Motor Protection
Mounting Type DIN Rail
Standards CCC
Trip Range 1.6–32 A (Series Capability)
Weight 0.8 lb

 

 

Information About 140M-D8E-C20

The 140M-D8E-C20 is part of the Allen-Bradley 140M series of motor protection circuit breakers, offering a compact, integrated solution for overload, short-circuit, and manual switching needs in motor branch circuits. As a D-frame device, it delivers higher performance capability, supporting operational voltages from 200 to 690 V and power ratings of 5.5 kW and 10 kW depending on supply voltage. This model uses a thermal-magnetic trip unit with an adjustable thermal setting between 14.5 and 20 A and a fixed magnetic trip for fast short-circuit protection. With a 100 kAIC interrupt rating and CCC certification, it is built for demanding industrial systems requiring dependable, high-capacity motor protection.

Key Features:

  • Thermal-Magnetic Trip Unit: Provides adjustable thermal overload protection from 14.5–20 A and fixed magnetic trip response for short-circuit safety.
  • High 100 kAIC Interrupt Rating: Ensures strong short-circuit clearing capability for rugged industrial environments.
  • D-Frame High-Performance Design: Supports larger motor loads with enhanced durability and improved fault withstand capability.
  • Wide 200–690 V Operating Range: Allows deployment across multiple industrial power systems and voltage classes.
  • Motor Protection Functionality: Combines overload, short-circuit, and disconnecting means in a single compact device.
  • Rated for 5.5 kW / 10 kW Motors: Compatible with a range of industrial motors depending on supply voltage.
  • DIN-Rail Mount Construction: Enables simple installation and integration into motor control panels and MCCs.
  • CCC Certified: Ensures compliance with international safety and performance requirements.

The 140M-D8E-C20 delivers the reliability and precision required for high-performance motor protection, coordinated overload response, and secure short-circuit handling in industrial applications.

Frequently Asked Questions about 140M-D8E-C20
Question: What is the purpose of the Allen-Bradley 140M-D8E-C20?
Date Update:13/06/2025
Answer:

The 140M-D8E-C20 is designed to provide overcurrent protection for electric motors. It helps to prevent motor damage caused by conditions such as overloads, short circuits, and phase loss. The breaker also provides protection against thermal overloads, ensuring motor safety and longevity.

Question: What is the current range for the 140M-D8E-C20 breaker?
Date Update:13/06/2025
Answer:

The 140M-D8E-C20 Motor Protection Circuit Breaker has an adjustable current range of 14.5 to 20 amps. This range allows for optimal protection depending on the motor's specific needs.

Question: What kind of maintenance is required for the 140M-D8E-C20?
Date Update:13/06/2025
Answer:

Regular inspections are recommended to ensure the breaker is functioning properly. Check for signs of wear or damage to the breaker’s components. Ensure that the breaker is free from dirt or debris and that the current setting is still appropriate for the motor.

Question: Is the Allen-Bradley 140M-D8E-C20 still available?
Date Update:13/06/2025
Answer:

The Allen-Bradley 140M-D8E-C20 Motor Protection Circuit Breaker has been discontinued by Rockwell Automation. If you are looking for a replacement or an alternative, Rockwell Automation recommends the 140MT-D9E-C20 as the updated model in the 140M series, which provides enhanced features while maintaining compatibility with the previous models.

Question: How do I replace the 140M-D8E-C20 if it becomes faulty?
Date Update:13/06/2025
Answer:

If the breaker needs to be replaced, first disconnect all power and safely remove the faulty breaker from the electrical panel. Install the new breaker by following the manufacturer's installation instructions and ensuring that all connections are secure. Verify the current settings and conduct a test to ensure proper operation.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Allen-Bradley 140M-D8E-C20 is a high-performance motor protection circuit breaker designed for thermal-magnetic protection in industrial motor circuits. It supports a 14.5–20 A adjustable trip range within a D-frame design and is rated for short-circuit interruption up to 100 kAIC.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Allen-Bradley
Category Circuit Protection
Part Number 140M-D8E-C20
Subcategory Motor Protection Circuit Breakers
Amperage Rating 14.5–20 A (Thermal Trip Range)
Frame D Frame
Trip Type Thermal Magnetic
Interrupt Rating 100 kAIC
Voltage Rating 200–690 V
Motor Power Rating 5.5 kW / 10 kW
Circuit Breaker Type Motor Protection Circuit Breaker
Application Motor Protection
Mounting Type DIN Rail
Standards CCC
Trip Range 1.6–32 A (Series Capability)
Weight 0.8 lb

 

 

Information About 140M-D8E-C20

The 140M-D8E-C20 is part of the Allen-Bradley 140M series of motor protection circuit breakers, offering a compact, integrated solution for overload, short-circuit, and manual switching needs in motor branch circuits. As a D-frame device, it delivers higher performance capability, supporting operational voltages from 200 to 690 V and power ratings of 5.5 kW and 10 kW depending on supply voltage. This model uses a thermal-magnetic trip unit with an adjustable thermal setting between 14.5 and 20 A and a fixed magnetic trip for fast short-circuit protection. With a 100 kAIC interrupt rating and CCC certification, it is built for demanding industrial systems requiring dependable, high-capacity motor protection.

Key Features:

  • Thermal-Magnetic Trip Unit: Provides adjustable thermal overload protection from 14.5–20 A and fixed magnetic trip response for short-circuit safety.
  • High 100 kAIC Interrupt Rating: Ensures strong short-circuit clearing capability for rugged industrial environments.
  • D-Frame High-Performance Design: Supports larger motor loads with enhanced durability and improved fault withstand capability.
  • Wide 200–690 V Operating Range: Allows deployment across multiple industrial power systems and voltage classes.
  • Motor Protection Functionality: Combines overload, short-circuit, and disconnecting means in a single compact device.
  • Rated for 5.5 kW / 10 kW Motors: Compatible with a range of industrial motors depending on supply voltage.
  • DIN-Rail Mount Construction: Enables simple installation and integration into motor control panels and MCCs.
  • CCC Certified: Ensures compliance with international safety and performance requirements.

The 140M-D8E-C20 delivers the reliability and precision required for high-performance motor protection, coordinated overload response, and secure short-circuit handling in industrial applications.