Product Overview
The Allen-Bradley 1420-V2-ENT PowerMonitor 500 Unit is a monitoring device designed for electrical systems, specifically r...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
Product comes with IQElectro 2-Year Warranty
Warranty for item #: 1420-V2-ENT
IQElectro International provides a 2-year warranty on every product we offer. Our complimentary 2-year warranty ensures that every IQElectro purchase is a trustworthy and reliable investment in the future of your company.
IQElectro is NOT an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.
1420-V2-ENT | Allen-Bradley | PowerMonitor
    1420-V2-ENT | Allen-Bradley | PowerMonitor
1420-V2-ENT | Allen-Bradley | PowerMonitor
Return/Exchange within 30-Days.
If any product is damaged upon delivery, you may request an Exchange or Refund within 30 days of receiving your order.
2-3-Day Free Shipping
"IQElectro provides free shipping within 2-3 days from the moment the order is placed on our website.

Product Description P/N: 1420-V2-ENT

Description / Specifications

Description


The Allen-Bradley 1420-V2-ENT PowerMonitor 500 Unit is designed for monitoring power systems with a maximum voltage of 600V AC. It does not provide any output functionality but is equipped with EtherNet/IP communications capability, allowing seamless integration into industrial networks for real-time monitoring and data collection. This unit serves as a crucial component in power management systems, offering comprehensive monitoring and analysis of electrical parameters to ensure optimal performance and efficiency of electrical systems in industrial settings.


Technical Specifications

 

Part #

1420-V2-ENT

Manufacturer

ALLEN BRADLEY

Category

Transmission Distribut. Relays

Subcategory

Voltage/Phase Monitor

Voltage (by direct connection or VT/PT)

400/600V LL

Input impedance

5(6)A, < 0.2VA

Current overloads

6 A, at 50/60 Hz, Continuous

Control power

Range: 100 to 240V AC (48 to 62 Hz)

Voltage overloads

2 × Vnom (where Vnom is the nominal voltage of the module), for 500 ms

Coupling type

With CTs

Temperature drift

≤ 200 ppm/°C

Current range (by CT)

5 A nominal (6 A maximum)

Rated inputs

System type: 1, 2, or 3-phase

Current type

Galvanic insulation with built-in CTs

Method

True RMS measurements of distorted wave forms

Sampling rate

3840 samples/second at 60 Hz, 3200 samples/second at 50 Hz

Energy additional errors

According to EN62053-21 ANSI C12.1, influence quantities Class B according to EN50470-3, EN62053-23

Current sensing

Nominal: 5 A

Voltage sensing

Nominal: 400V AC LN, 600V AC LL Range: 160 to 480V AC LN RMS, 277 to 830V AC LL RMS

Height

Front dimensions: 96 mm

Width

Front dimensions: 96 mm

Accuracy

Voltage, nominal: 400V AC LN, 600V AC LL @ 25 °C ±5 °C, R.H. ≤ 60%, 48...62 Hz

Optional Ethernet port supporting

EtherNet/IP and Modbus TCP/IP

System and single phase average and maximum variables

Yes

Real-time clock function

Yes

Run hours counter

8+2 digits

Energy measurements (imported/exported)

kWh and kVARh

Front protection degree

IP65, NEMA 4X, NEMA 12

Metering values display

Four rows with 4 digits

Energy value display

Ten digits and the plus/minus sign

Universal power supply

120/240V AC 50/60 Hz or 120/240V DC

Revenue grade energy measurements

Per ANSI C12.1 Class 1.0, ANSI C12.1

configurable virtual alarms

Up to four configurable virtual alarms

Three-phase (system) variables

V(L-L), V(L-N), A, VA, W, VAR, power factor, frequency

Single phase variables

V(L-L), V(L-N), A(L), An (calculated), VA, W, VAR, power factor

Class

• Class 1 (kWh) according to EN62053-21, • Class B (kWh) according to EN50470-3, • Class 2 (kVARh) according to EN62053-23

Line-neutral RMS

Maximum @ 160 to 480V AC

Line-line RMS

Maximum @ 277 to 830V AC

Start up current

5

Current sensing model

Inominal: 5 A, Imaximum: 6A

Line-neutral voltage

In the range Vnom: ±(0.5% RDG +1 digit)

Line-line voltage

In the range Vnom: ±(1.0% RDG +1 digit)

Current all models

From 0.01 to 0.25 A: ±(1.0% of reading (RDG) + 2 digits From 0.25 to 6 A: ±(0.5% RDG +2 digits)

Real and apparent power

From 0.05 to 0.25 A, PF 1: ±(2% RDG +1 digit) From 0.25 to 6A, PF 0.5L, PF1, PF 0.8C: ±(1.0% RDG+1 digit)

Crest factor

≤3 (15 A max peak)

Power factor

PF: Yes

Reactive energy (kVARh)

Class 2 according to EN62053-23, ANSI C12.1

Frequency

Hz: Yes

Real energy (kWh)

Class 1 according to EN62053-21, ANSI C12.1 Class B according to EN50470-3

Reactive power (kVAR)

Yes

Current

Yes

Real power (kW)

Yes

Apparent power (kVA)

Yes

Real power consumption (kWh)

Yes

Reactive power consumption (kVARh)

Yes

Apparent power consumption (kVAh)

Yes

Demand power factor

Yes

Demand (kW)

Yes

Demand (kVAR)

Yes

Demand (kVA)

Yes

Voltage

Yes

Immunity to radiated electromagnetic fields

Test without any current: 30V/m from 80 to 2000 MHz

Storage temperature

-30 to +70 °C (-22 to +158 °F) (R.H.P178 < 90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053-23

Operating temperature

-25 to +40 °C (-13 to +104 °F) (R.H. from 0…90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053-23

Noise rejection CMRR

100 dB, 48 to 62 Hz

Electrostatic discharge

15 kV air discharge

Radio frequency suppression

According to CISPR 22

EMC

According to EN62052-11

Dielectric strength

4 kV AC rms for 1 minute

Installation category

Cat. III (IEC60664, EN60664)

Immunity to conducted disturbances

10V/m from 150 KHz to 80 MHz

Burst

On current and voltage measuring inputs circuit: 4 kV

Surge

On current and voltage measuring inputs circuit: 4 kV, on ‘L’ auxiliary power supply input: 1 kV

 

Information About 1420-V2-ENT


The Allen-Bradley 1420-V2-ENT PowerMonitor 500 Unit is a monitoring device designed for electrical systems, offering comprehensive functionality within industrial environments. With a voltage rating of 600V AC, it provides robust monitoring capabilities suitable for various power systems.

The primary feature of the 1420-V2-ENT PowerMonitor 500 Unit is its ability to monitor electrical parameters efficiently. It is equipped with EtherNet/IP communications, enabling seamless integration into industrial networks for real-time data access and control. This feature enhances its versatility and compatibility with modern automation systems.

Notably, the PowerMonitor 500 Unit does not provide any output functionality, focusing solely on monitoring and data transmission capabilities. This design ensures a streamlined approach to monitoring without additional output features, making it ideal for applications where monitoring is the primary requirement.

With its EtherNet/IP communications protocol, the PowerMonitor 500 Unit facilitates easy integration into existing industrial networks, allowing for efficient data exchange and communication with other devices and systems. This capability enhances system visibility and enables operators to make informed decisions based on real-time data insights.

 



Manufacturer information

Allen‑Bradley components, integrated control and information solutions are built for demanding industrial applications. We integrate control and information across the enterprise to make you as productive as possible.

Warrany image

IQElectro 2 Year Warranty

IQElectro offers a 2-Year Warranty on all our products. This complimentary two-year warranty ensures that every purchase from IQElectro is a secure investment in the future of your company.
Warranty Terms and Conditions
warningIQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses. Some hardware products may contain software and firmware and may not be legally operated without first obtaining an appropriate license from the manufacturer. IQElectro makes no representation as to whether a product will or will not have software or firmware and, if it does, whether the software or firmware is the revision level that you need for your application. IQElectro also makes no representations as to your ability or right to download or otherwise obtain software or firmware for the product from the Original Manufacturer, its distributors, or any other source. IQElectro also makes no representations as to your right to install any such software or firmware on the product. IQElectro will not obtain or supply software or firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing software or firmware. Customer acknowledges and agrees that IQElectro DOES NOT provide any software, firmware, operating system, or right-to-use licenses with the products it sells. Customers understand and agree that proper software (firmware) licensing, maintenance, and upgrades are subject to the applicable manufacturer's Licensing Agreement or similar document. Disclaimer Policy.
Description / Specifications

Description


The Allen-Bradley 1420-V2-ENT PowerMonitor 500 Unit is designed for monitoring power systems with a maximum voltage of 600V AC. It does not provide any output functionality but is equipped with EtherNet/IP communications capability, allowing seamless integration into industrial networks for real-time monitoring and data collection. This unit serves as a crucial component in power management systems, offering comprehensive monitoring and analysis of electrical parameters to ensure optimal performance and efficiency of electrical systems in industrial settings.


Technical Specifications

 

Part #

1420-V2-ENT

Manufacturer

ALLEN BRADLEY

Category

Transmission Distribut. Relays

Subcategory

Voltage/Phase Monitor

Voltage (by direct connection or VT/PT)

400/600V LL

Input impedance

5(6)A, < 0.2VA

Current overloads

6 A, at 50/60 Hz, Continuous

Control power

Range: 100 to 240V AC (48 to 62 Hz)

Voltage overloads

2 × Vnom (where Vnom is the nominal voltage of the module), for 500 ms

Coupling type

With CTs

Temperature drift

≤ 200 ppm/°C

Current range (by CT)

5 A nominal (6 A maximum)

Rated inputs

System type: 1, 2, or 3-phase

Current type

Galvanic insulation with built-in CTs

Method

True RMS measurements of distorted wave forms

Sampling rate

3840 samples/second at 60 Hz, 3200 samples/second at 50 Hz

Energy additional errors

According to EN62053-21 ANSI C12.1, influence quantities Class B according to EN50470-3, EN62053-23

Current sensing

Nominal: 5 A

Voltage sensing

Nominal: 400V AC LN, 600V AC LL Range: 160 to 480V AC LN RMS, 277 to 830V AC LL RMS

Height

Front dimensions: 96 mm

Width

Front dimensions: 96 mm

Accuracy

Voltage, nominal: 400V AC LN, 600V AC LL @ 25 °C ±5 °C, R.H. ≤ 60%, 48...62 Hz

Optional Ethernet port supporting

EtherNet/IP and Modbus TCP/IP

System and single phase average and maximum variables

Yes

Real-time clock function

Yes

Run hours counter

8+2 digits

Energy measurements (imported/exported)

kWh and kVARh

Front protection degree

IP65, NEMA 4X, NEMA 12

Metering values display

Four rows with 4 digits

Energy value display

Ten digits and the plus/minus sign

Universal power supply

120/240V AC 50/60 Hz or 120/240V DC

Revenue grade energy measurements

Per ANSI C12.1 Class 1.0, ANSI C12.1

configurable virtual alarms

Up to four configurable virtual alarms

Three-phase (system) variables

V(L-L), V(L-N), A, VA, W, VAR, power factor, frequency

Single phase variables

V(L-L), V(L-N), A(L), An (calculated), VA, W, VAR, power factor

Class

• Class 1 (kWh) according to EN62053-21, • Class B (kWh) according to EN50470-3, • Class 2 (kVARh) according to EN62053-23

Line-neutral RMS

Maximum @ 160 to 480V AC

Line-line RMS

Maximum @ 277 to 830V AC

Start up current

5

Current sensing model

Inominal: 5 A, Imaximum: 6A

Line-neutral voltage

In the range Vnom: ±(0.5% RDG +1 digit)

Line-line voltage

In the range Vnom: ±(1.0% RDG +1 digit)

Current all models

From 0.01 to 0.25 A: ±(1.0% of reading (RDG) + 2 digits From 0.25 to 6 A: ±(0.5% RDG +2 digits)

Real and apparent power

From 0.05 to 0.25 A, PF 1: ±(2% RDG +1 digit) From 0.25 to 6A, PF 0.5L, PF1, PF 0.8C: ±(1.0% RDG+1 digit)

Crest factor

≤3 (15 A max peak)

Power factor

PF: Yes

Reactive energy (kVARh)

Class 2 according to EN62053-23, ANSI C12.1

Frequency

Hz: Yes

Real energy (kWh)

Class 1 according to EN62053-21, ANSI C12.1 Class B according to EN50470-3

Reactive power (kVAR)

Yes

Current

Yes

Real power (kW)

Yes

Apparent power (kVA)

Yes

Real power consumption (kWh)

Yes

Reactive power consumption (kVARh)

Yes

Apparent power consumption (kVAh)

Yes

Demand power factor

Yes

Demand (kW)

Yes

Demand (kVAR)

Yes

Demand (kVA)

Yes

Voltage

Yes

Immunity to radiated electromagnetic fields

Test without any current: 30V/m from 80 to 2000 MHz

Storage temperature

-30 to +70 °C (-22 to +158 °F) (R.H.P178 < 90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053-23

Operating temperature

-25 to +40 °C (-13 to +104 °F) (R.H. from 0…90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053-23

Noise rejection CMRR

100 dB, 48 to 62 Hz

Electrostatic discharge

15 kV air discharge

Radio frequency suppression

According to CISPR 22

EMC

According to EN62052-11

Dielectric strength

4 kV AC rms for 1 minute

Installation category

Cat. III (IEC60664, EN60664)

Immunity to conducted disturbances

10V/m from 150 KHz to 80 MHz

Burst

On current and voltage measuring inputs circuit: 4 kV

Surge

On current and voltage measuring inputs circuit: 4 kV, on ‘L’ auxiliary power supply input: 1 kV

 

Information About 1420-V2-ENT


The Allen-Bradley 1420-V2-ENT PowerMonitor 500 Unit is a monitoring device designed for electrical systems, offering comprehensive functionality within industrial environments. With a voltage rating of 600V AC, it provides robust monitoring capabilities suitable for various power systems.

The primary feature of the 1420-V2-ENT PowerMonitor 500 Unit is its ability to monitor electrical parameters efficiently. It is equipped with EtherNet/IP communications, enabling seamless integration into industrial networks for real-time data access and control. This feature enhances its versatility and compatibility with modern automation systems.

Notably, the PowerMonitor 500 Unit does not provide any output functionality, focusing solely on monitoring and data transmission capabilities. This design ensures a streamlined approach to monitoring without additional output features, making it ideal for applications where monitoring is the primary requirement.

With its EtherNet/IP communications protocol, the PowerMonitor 500 Unit facilitates easy integration into existing industrial networks, allowing for efficient data exchange and communication with other devices and systems. This capability enhances system visibility and enables operators to make informed decisions based on real-time data insights.

 



Manufacturer information

Allen‑Bradley components, integrated control and information solutions are built for demanding industrial applications. We integrate control and information across the enterprise to make you as productive as possible.

Check Out These Related Products

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)