Product Overview
Allen-Bradley 1734-IB8SK POINT Digital DC Input Module 24V DC 8-Ch Sink Safety-Rated, 8 Safety-Rated Sink Inputs 24V DC (1...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Contact Us!

Talk to a real expert.

Mon–Sat, 7:00 AM – 8:00 PM (EST)
warranty
IQElectro 2-Year Warranty
Warranty for Product #: 1734-IB8SK
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro BBB Business Review
IQElectro is Not an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: 1734-IB8SK

Description / Specifications

Description 

The Allen-Bradley 1734-IB8SK is a safety-rated digital input module designed for POINT Guard I/O systems. Identified by part number 1734-IB8SK, it provides eight sinking safety input channels supporting 18–30 VDC operation with integrated pulse-test outputs. With conformal coating and compatibility with GuardLogix, Compact GuardLogix, and SmartGuard controllers, it is suited for distributed safety architectures.

 

 

Technical Specifications

Condition New/Never Used Surplus
Brand Allen-Bradley
Category PLCs/Machine Control
Part Number 1734-IB8SK
Subcategory Safety I/O Module
Series POINT Guard I/O
Product Type Digital Safety Input Module
Number of Inputs 8 sinking inputs
Input Voltage Range 18–30 VDC
Minimum On-State Current 3.3 mA
Maximum Off-State Current 1.3 mA
Input Reaction Time <16.2 ms
Pulse Test Outputs 4 (current sourcing)
Pulse Test Output Current (per channel) 0.7 A max
Pulse Test Output Current (per module) 2.8 A @ 40 °C
Terminal Base Type 8-point terminal base
Conformal Coating Yes
Safety Compliance SIL 3 / Cat. 3 and 4 / PL e
Compatible Controllers GuardLogix, Compact GuardLogix, SmartGuard
Mounting POINT I/O terminal base (DIN rail assembly)
Enclosure Type Open-style
Operating Temperature As per POINT Guard I/O environmental ratings

 

 

Information About 1734-IB8SK

The 1734-IB8SK is part of the POINT Guard I/O family designed for applications requiring safety performance up to SIL 3 / Cat. 4. Its construction includes a conformal-coated housing and an 8-point terminal base interface supporting single- and dual-channel safety input configurations. The module integrates seamlessly into GuardLogix-based systems, offering <16.2 ms reaction time and four current-sourcing pulse-test outputs for device monitoring such as switches, light curtains, and emergency stops. Typical usage includes distributed safety I/O installations in machine guarding, emergency stop networks, and safety-related automation requiring high diagnostic coverage.

Key Features:

  • Eight safety inputs: Sinking digital channels for safety devices such as E-stops and gate switches.
  • Safety-rated design: Suitable for SIL 3, Performance Level e, and Category 3/4 applications.
  • Conformal coating: Enhances resistance to corrosive and harsh industrial environments.
  • Pulse-test capability: Provides four sourcing outputs for detecting wiring and device faults.
  • Fast reaction time: Input response of less than 16.2 ms for safety-critical control.
  • Wide voltage range: Operates from 18–30 VDC for flexible field wiring.
  • Compatible with safety controllers: Integrates with GuardLogix, Compact GuardLogix, and SmartGuard.
  • Modular POINT I/O design: Supports distributed mounting via 8-point terminal bases.

The 1734-IB8SK delivers the reliability and precision required for high-integrity safety input monitoring in distributed automation systems.

Frequently Asked Questions about 1734-IB8SK
Question: What is the 1734‑IB8SK module used for?
Date Update:18/06/2025
Answer:

The 1734‑IB8SK is a sinking, safety-rated digital input module with 8 channels, part of the POINT Guard I/O family from Rockwell Automation. It’s designed for safety-critical control systems (SIL 3 / PL e), capturing safety input signals (e.g., emergency stops, safety gates) and communicating back to GuardLogix or SmartGuard controllers over DeviceNet or EtherNet/IP.

Question: What are its key electrical specifications?
Date Update:18/06/2025
Answer:
  • Input channels: 8 sinking digital inputs
  • Voltage supply: 24 V DC
  • Input type: Sinking (current sinks to input when active)
  • I/O protection: Conformal coating, IP20-rated, DIN-rail mountable
Question: How is it installed and wired?
Date Update:18/06/2025
Answer:
  • Terminal base: Fits into standard POINT I/O DIN-rail mount bases (e.g., 1734-TB series)
  • Wiring: Use sinking inputs connected to 24 V DC field wiring. Follow guidelines in the POINT Guard I/O Installation Manual (1734-IN016) for grounding, spacing, and safety protocols. Include 2" clearance above modules for heat dissipation
Question: How is the 1734-IB8SK configured in a safety control system?
Date Update:18/06/2025
Answer:

The configuration process generally includes these steps:

  1. Physical Installation: Mount the module on a POINT I/O DIN rail assembly. Connect it via a POINT I/O communication adapter such as 1734-AENT for EtherNet/IP.
  2. Controller Setup: Add the module to your Studio 5000 or RSLogix 5000 project under a GuardLogix or SmartGuard controller.
  3. Safety Configuration:
  • Define each channel’s function (single- or dual-channel).
  • Set input filter times and debounce logic.
  • Enable diagnostics for fault detection.
  • Assign safe states and fault responses.

After setup, the controller will exchange safety I/O data with the module in accordance with CIP Safety protocol, which provides data integrity and timestamp verification.

Question: Can the 1734-IB8SK be used in redundant safety applications?
Date Update:18/06/2025
Answer:

Yes. The module supports dual-channel safety input configurations, which are fundamental in redundant safety architectures. Redundancy ensures that if one signal path fails (due to wiring or device error), the other path can still be used to safely detect the fault.

For example, if you're monitoring a dual-contact emergency stop button, each contact can be wired to separate inputs. The module can be configured to check whether both contacts open and close simultaneously, enforcing category 3 or 4 safety behavior depending on the overall system architecture.

In addition, the POINT Guard system allows for individual input validation, meaning each safety input channel can be monitored independently with its own safety logic.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Allen-Bradley 1734-IB8SK is a safety-rated digital input module designed for POINT Guard I/O systems. Identified by part number 1734-IB8SK, it provides eight sinking safety input channels supporting 18–30 VDC operation with integrated pulse-test outputs. With conformal coating and compatibility with GuardLogix, Compact GuardLogix, and SmartGuard controllers, it is suited for distributed safety architectures.

 

 

Technical Specifications

Condition New/Never Used Surplus
Brand Allen-Bradley
Category PLCs/Machine Control
Part Number 1734-IB8SK
Subcategory Safety I/O Module
Series POINT Guard I/O
Product Type Digital Safety Input Module
Number of Inputs 8 sinking inputs
Input Voltage Range 18–30 VDC
Minimum On-State Current 3.3 mA
Maximum Off-State Current 1.3 mA
Input Reaction Time <16.2 ms
Pulse Test Outputs 4 (current sourcing)
Pulse Test Output Current (per channel) 0.7 A max
Pulse Test Output Current (per module) 2.8 A @ 40 °C
Terminal Base Type 8-point terminal base
Conformal Coating Yes
Safety Compliance SIL 3 / Cat. 3 and 4 / PL e
Compatible Controllers GuardLogix, Compact GuardLogix, SmartGuard
Mounting POINT I/O terminal base (DIN rail assembly)
Enclosure Type Open-style
Operating Temperature As per POINT Guard I/O environmental ratings

 

 

Information About 1734-IB8SK

The 1734-IB8SK is part of the POINT Guard I/O family designed for applications requiring safety performance up to SIL 3 / Cat. 4. Its construction includes a conformal-coated housing and an 8-point terminal base interface supporting single- and dual-channel safety input configurations. The module integrates seamlessly into GuardLogix-based systems, offering <16.2 ms reaction time and four current-sourcing pulse-test outputs for device monitoring such as switches, light curtains, and emergency stops. Typical usage includes distributed safety I/O installations in machine guarding, emergency stop networks, and safety-related automation requiring high diagnostic coverage.

Key Features:

  • Eight safety inputs: Sinking digital channels for safety devices such as E-stops and gate switches.
  • Safety-rated design: Suitable for SIL 3, Performance Level e, and Category 3/4 applications.
  • Conformal coating: Enhances resistance to corrosive and harsh industrial environments.
  • Pulse-test capability: Provides four sourcing outputs for detecting wiring and device faults.
  • Fast reaction time: Input response of less than 16.2 ms for safety-critical control.
  • Wide voltage range: Operates from 18–30 VDC for flexible field wiring.
  • Compatible with safety controllers: Integrates with GuardLogix, Compact GuardLogix, and SmartGuard.
  • Modular POINT I/O design: Supports distributed mounting via 8-point terminal bases.

The 1734-IB8SK delivers the reliability and precision required for high-integrity safety input monitoring in distributed automation systems.