Product Description P/N: 1734-IB8SK
Description
The Allen-Bradley 1734-IB8SK is a safety-rated digital input module designed for POINT Guard I/O systems. Identified by part number 1734-IB8SK, it provides eight sinking safety input channels supporting 18–30 VDC operation with integrated pulse-test outputs. With conformal coating and compatibility with GuardLogix, Compact GuardLogix, and SmartGuard controllers, it is suited for distributed safety architectures.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Allen-Bradley |
| Category | PLCs/Machine Control |
| Part Number | 1734-IB8SK |
| Subcategory | Safety I/O Module |
| Series | POINT Guard I/O |
| Product Type | Digital Safety Input Module |
| Number of Inputs | 8 sinking inputs |
| Input Voltage Range | 18–30 VDC |
| Minimum On-State Current | 3.3 mA |
| Maximum Off-State Current | 1.3 mA |
| Input Reaction Time | <16.2 ms |
| Pulse Test Outputs | 4 (current sourcing) |
| Pulse Test Output Current (per channel) | 0.7 A max |
| Pulse Test Output Current (per module) | 2.8 A @ 40 °C |
| Terminal Base Type | 8-point terminal base |
| Conformal Coating | Yes |
| Safety Compliance | SIL 3 / Cat. 3 and 4 / PL e |
| Compatible Controllers | GuardLogix, Compact GuardLogix, SmartGuard |
| Mounting | POINT I/O terminal base (DIN rail assembly) |
| Enclosure Type | Open-style |
| Operating Temperature | As per POINT Guard I/O environmental ratings |
Information About 1734-IB8SK
The 1734-IB8SK is part of the POINT Guard I/O family designed for applications requiring safety performance up to SIL 3 / Cat. 4. Its construction includes a conformal-coated housing and an 8-point terminal base interface supporting single- and dual-channel safety input configurations. The module integrates seamlessly into GuardLogix-based systems, offering <16.2 ms reaction time and four current-sourcing pulse-test outputs for device monitoring such as switches, light curtains, and emergency stops. Typical usage includes distributed safety I/O installations in machine guarding, emergency stop networks, and safety-related automation requiring high diagnostic coverage.
Key Features:
- Eight safety inputs: Sinking digital channels for safety devices such as E-stops and gate switches.
- Safety-rated design: Suitable for SIL 3, Performance Level e, and Category 3/4 applications.
- Conformal coating: Enhances resistance to corrosive and harsh industrial environments.
- Pulse-test capability: Provides four sourcing outputs for detecting wiring and device faults.
- Fast reaction time: Input response of less than 16.2 ms for safety-critical control.
- Wide voltage range: Operates from 18–30 VDC for flexible field wiring.
- Compatible with safety controllers: Integrates with GuardLogix, Compact GuardLogix, and SmartGuard.
- Modular POINT I/O design: Supports distributed mounting via 8-point terminal bases.
The 1734-IB8SK delivers the reliability and precision required for high-integrity safety input monitoring in distributed automation systems.
Description
The Allen-Bradley 1734-IB8SK is a safety-rated digital input module designed for POINT Guard I/O systems. Identified by part number 1734-IB8SK, it provides eight sinking safety input channels supporting 18–30 VDC operation with integrated pulse-test outputs. With conformal coating and compatibility with GuardLogix, Compact GuardLogix, and SmartGuard controllers, it is suited for distributed safety architectures.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Allen-Bradley |
| Category | PLCs/Machine Control |
| Part Number | 1734-IB8SK |
| Subcategory | Safety I/O Module |
| Series | POINT Guard I/O |
| Product Type | Digital Safety Input Module |
| Number of Inputs | 8 sinking inputs |
| Input Voltage Range | 18–30 VDC |
| Minimum On-State Current | 3.3 mA |
| Maximum Off-State Current | 1.3 mA |
| Input Reaction Time | <16.2 ms |
| Pulse Test Outputs | 4 (current sourcing) |
| Pulse Test Output Current (per channel) | 0.7 A max |
| Pulse Test Output Current (per module) | 2.8 A @ 40 °C |
| Terminal Base Type | 8-point terminal base |
| Conformal Coating | Yes |
| Safety Compliance | SIL 3 / Cat. 3 and 4 / PL e |
| Compatible Controllers | GuardLogix, Compact GuardLogix, SmartGuard |
| Mounting | POINT I/O terminal base (DIN rail assembly) |
| Enclosure Type | Open-style |
| Operating Temperature | As per POINT Guard I/O environmental ratings |
Information About 1734-IB8SK
The 1734-IB8SK is part of the POINT Guard I/O family designed for applications requiring safety performance up to SIL 3 / Cat. 4. Its construction includes a conformal-coated housing and an 8-point terminal base interface supporting single- and dual-channel safety input configurations. The module integrates seamlessly into GuardLogix-based systems, offering <16.2 ms reaction time and four current-sourcing pulse-test outputs for device monitoring such as switches, light curtains, and emergency stops. Typical usage includes distributed safety I/O installations in machine guarding, emergency stop networks, and safety-related automation requiring high diagnostic coverage.
Key Features:
- Eight safety inputs: Sinking digital channels for safety devices such as E-stops and gate switches.
- Safety-rated design: Suitable for SIL 3, Performance Level e, and Category 3/4 applications.
- Conformal coating: Enhances resistance to corrosive and harsh industrial environments.
- Pulse-test capability: Provides four sourcing outputs for detecting wiring and device faults.
- Fast reaction time: Input response of less than 16.2 ms for safety-critical control.
- Wide voltage range: Operates from 18–30 VDC for flexible field wiring.
- Compatible with safety controllers: Integrates with GuardLogix, Compact GuardLogix, and SmartGuard.
- Modular POINT I/O design: Supports distributed mounting via 8-point terminal bases.
The 1734-IB8SK delivers the reliability and precision required for high-integrity safety input monitoring in distributed automation systems.