1747-L542 | Allen-Bradley SLC 5/04 CPU Controller 32K DH+ & RS-232 Ports
1747-L542 | Allen-Bradley SLC 5/04 CPU Controller 32K DH+ & RS-232 Ports
1747-L542 | Allen-Bradley SLC 5/04 CPU Controller 32K DH+ & RS-232 Ports
    1747-L542 | Allen-Bradley SLC 5/04 CPU Controller 32K DH+ & RS-232 Ports
1747-L542 | Allen-Bradley SLC 5/04 CPU Controller 32K DH+ & RS-232 Ports

1747-L542 | Allen-Bradley SLC 5/04 CPU Controller 32K DH+ & RS-232 Ports

Part #: 1747-L542 Manufactured by: Allen-Bradley
Regular price
$1,350.00
Sale price
$1,350.00
Regular price
8 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The Allen-Bradley 1747-L542 is a SLC 500 SLC 5/04 Processor. This SLC 5/04 Processor has 4096 Inputs points and 4096 Outpu...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: 1747-L542
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: 1747-L542

Description / Specifications

Description 

The 1747-L541 is a controller module for the SLC 500 Modular Hardware by Allen-Bradley. It comes with Memory or 32 KB, and built-in communication interfaces such as 9-Pin RS-232 and Data Highway Plus (DH+). It is capable of 4096 Inputs points and 4096 Outputs points with an Analog I/O count of 480 point.

 

Technical Specifications 

 

Brand Allen-Bradley
Series SLC 500
Part Number 1747-L542
Manufacturer Rockwell Automation
Inputs 4096
Module Type SLC 5/04 Processor
Outputs 4096
Analog I/O 480
Memory Up to 32 KB, Battery Backed-RAM
Program Scan Time 0.9 ms/K
User Memory 32,000 Words
I/O Chassis 3
Chassis Module Slots 30
I/O Scan Time 0.225 milliseconds
Communication Data Highway Plus (DH+), RS-232
Backup Memory 1747-M13
Ambient Temperature 0 to 60 degrees Celsius
Battery back-up memory Yes; 1747-BA

  

 

Information About 1747-L542

The 1747-L542 SLC is an SLC 5/03 controller. This controller is one of the Three (3) controllers under the 1747-L52 SLC 5/03 category. This controller is the mid-range controller of SLC 5/03 which has 32 KB user memory while still capable of handling 4096 Input and outputs.

The 1747-L542 is used with the modular style hardware. This processor is installed to slot Zero (0) of any SLC chassis such as 1746-A2, 1746-A7, 1746-A10 and 1746-A13. It is powered though the power supplied in the backplane, provided by the system power supply installed at the leftmost area of the chassis.

This SLC processor has integrated RS232 and Data Highway Plus (DH+) communication port which allows this processor to be communicated with computer-based control systems such as Human Machine Interface (HMI) or Supervisory Control and Data Acquisition (SCADA). This processor may also be used for messaging or implement pass-through communication for other Allen-Bradley Programable Logic Controller (PLC) such as PLC 5, CompactLogix and ControlLogix platforms.

This processor is built with status indicators such as Run, CPU Fault, Forced I/O, Battery Low, RS-232 and DH+ LEDs. It is also provided with a key for switching the processor’s operating mode.

The Allen-Bradley 1747-L542 is an SLC 500 SLC 5/04 modular processing unit that has the capacity to handle 32K words, specifically 4K data storage and 28K words for program data. It has an absolute maximum of 4096 discrete inputs and 4096 discrete outputs, with 480 maximum local analog I/O. The 1747-L542 also has a maximum of 3 local I/O chassis, with a maximum of 30 slots in the local I/O chassis. Its I/O scan time is 0.255 milliseconds, typical program scan time is 0.9 milliseconds/Kword, and bit execution time is 0.37 milliseconds, with a program scan holdup time of 20 milliseconds to 3 seconds after a power loss.

The power scan hold-up time depends on the loading of the power supply. It also uses a Flash EPROM for its memory back-up and the 32KB RAM of the 1747-L542 processor is battery-backed. Communication ports present are an RS-232 port and a DH+ port. Status LEDs are also available, specifically for low battery, CPU fault, run, forced I/O, DH+, and RS-232. The 1747-L542’s backplane current is 1 A at 5 Volts DC and the current is 175 mA at 24 Volts DC. It operates at a temperature between 32 - 140 degrees Fahrenheit and it can be stored at a temperature between -40- and 185-degrees Fahrenheit, with an ambient relative humidity of 5 to 95%, non-condensing. This processor’s acceleration is 2.5G at 57 to 2000 Hertz, its displacement is 0.015 inches, peak-to-peak, at 5 to 57 Hertz, and its operating shock is 30G.



Manufacturer information

Allen-Bradley, a brand of Rockwell Automation, specializes in manufacturing industrial automation equipment. The product range includes programmable logic controllers (PLCs), motion control systems, safety devices, motor control equipment, automation software, and HMI panels. Allen-Bradley products are known for their reliability and integration with other systems.

Frequently Asked Questions about 1747-L542
Question: What is the 1747-L542?
Date Update:04/06/2025
Answer:

The 1747-L542 is a SLC 500 processor (PLC) from Allen-Bradley. It is part of the SLC 5/04 family and has 64K of user memory. The module provides high-speed processing, with a 4K I/O capacity and built-in communication ports (DF1 and DH+), allowing it to interface with remote I/O modules, HMIs, and other systems. It is used for a wide range of industrial automation applications.

Question: What are the key features of the 1747-L542?
Date Update:04/06/2025
Answer:

Key features of the 1747-L542 processor include:

  • 64K User Memory for program and data storage.
  • I/O Capacity: Supports up to 4K I/O modules, expandable with additional racks.
  • Communication Ports: Built-in DF1 (serial) and DH+ (Data Highway Plus) communication ports for network communication.
  • Processing Speed: Suitable for medium-scale applications requiring fast processing times.
  • Battery-Backed RAM to retain memory during power outages.
  • Compact Size: Fits in SLC 500 chassis for easier integration and flexibility in system design.
Question: What software do I need to program the 1747-L542?
Date Update:04/06/2025
Answer:

To program the 1747-L542, you need RSLogix 500 software. This software is used to configure and program the SLC 500 series processors. It provides features for

  • I/O configuration.
  • Ladder logic programming.
  • Diagnostics and troubleshooting.
  • Communication setup (DF1, DH+, etc.).

RSLogix 500 can be used to develop and download the control program to the 1747-L542 processor.

Question: How do I configure communication for the 1747-L542 processor?
Date Update:04/06/2025
Answer:

To configure communication on the 1747-L542:

  1. DH+ Configuration: In RSLogix 500, configure the DH+ node address for the processor. The DH+ address is needed for communication with other devices over the DH+ network.
  2. DF1 Configuration: Set up the DF1 communication settings to communicate with external devices, such as HMIs, other processors, or programming devices.
  3. Network Configuration: Use the communication configuration tool in RSLogix 500 to set baud rates, node addresses, and other parameters for communication.
  4. Network Setup: Ensure that the network cables are correctly connected to the appropriate ports (DF1 and DH+) for communication with the controller and remote devices.

For specific communication setup, refer to the manual.

Question: How do I perform a factory reset on the 1747-L542?
Date Update:04/06/2025
Answer:

To reset the 1747-L542 processor to factory defaults:

  1. Power off the processor.
  2. Press and hold the Reset button on the processor’s front panel.
  3. Power on the processor while continuing to hold the Reset button.
  4. After a few seconds, release the button. The processor will return to its factory settings.

Note: This will erase the current program, so ensure that you have a backup if needed before performing the reset.

IQElectro is not an authorized distributor.
QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The 1747-L541 is a controller module for the SLC 500 Modular Hardware by Allen-Bradley. It comes with Memory or 32 KB, and built-in communication interfaces such as 9-Pin RS-232 and Data Highway Plus (DH+). It is capable of 4096 Inputs points and 4096 Outputs points with an Analog I/O count of 480 point.

 

Technical Specifications 

 

Brand Allen-Bradley
Series SLC 500
Part Number 1747-L542
Manufacturer Rockwell Automation
Inputs 4096
Module Type SLC 5/04 Processor
Outputs 4096
Analog I/O 480
Memory Up to 32 KB, Battery Backed-RAM
Program Scan Time 0.9 ms/K
User Memory 32,000 Words
I/O Chassis 3
Chassis Module Slots 30
I/O Scan Time 0.225 milliseconds
Communication Data Highway Plus (DH+), RS-232
Backup Memory 1747-M13
Ambient Temperature 0 to 60 degrees Celsius
Battery back-up memory Yes; 1747-BA

  

 

Information About 1747-L542

The 1747-L542 SLC is an SLC 5/03 controller. This controller is one of the Three (3) controllers under the 1747-L52 SLC 5/03 category. This controller is the mid-range controller of SLC 5/03 which has 32 KB user memory while still capable of handling 4096 Input and outputs.

The 1747-L542 is used with the modular style hardware. This processor is installed to slot Zero (0) of any SLC chassis such as 1746-A2, 1746-A7, 1746-A10 and 1746-A13. It is powered though the power supplied in the backplane, provided by the system power supply installed at the leftmost area of the chassis.

This SLC processor has integrated RS232 and Data Highway Plus (DH+) communication port which allows this processor to be communicated with computer-based control systems such as Human Machine Interface (HMI) or Supervisory Control and Data Acquisition (SCADA). This processor may also be used for messaging or implement pass-through communication for other Allen-Bradley Programable Logic Controller (PLC) such as PLC 5, CompactLogix and ControlLogix platforms.

This processor is built with status indicators such as Run, CPU Fault, Forced I/O, Battery Low, RS-232 and DH+ LEDs. It is also provided with a key for switching the processor’s operating mode.

The Allen-Bradley 1747-L542 is an SLC 500 SLC 5/04 modular processing unit that has the capacity to handle 32K words, specifically 4K data storage and 28K words for program data. It has an absolute maximum of 4096 discrete inputs and 4096 discrete outputs, with 480 maximum local analog I/O. The 1747-L542 also has a maximum of 3 local I/O chassis, with a maximum of 30 slots in the local I/O chassis. Its I/O scan time is 0.255 milliseconds, typical program scan time is 0.9 milliseconds/Kword, and bit execution time is 0.37 milliseconds, with a program scan holdup time of 20 milliseconds to 3 seconds after a power loss.

The power scan hold-up time depends on the loading of the power supply. It also uses a Flash EPROM for its memory back-up and the 32KB RAM of the 1747-L542 processor is battery-backed. Communication ports present are an RS-232 port and a DH+ port. Status LEDs are also available, specifically for low battery, CPU fault, run, forced I/O, DH+, and RS-232. The 1747-L542’s backplane current is 1 A at 5 Volts DC and the current is 175 mA at 24 Volts DC. It operates at a temperature between 32 - 140 degrees Fahrenheit and it can be stored at a temperature between -40- and 185-degrees Fahrenheit, with an ambient relative humidity of 5 to 95%, non-condensing. This processor’s acceleration is 2.5G at 57 to 2000 Hertz, its displacement is 0.015 inches, peak-to-peak, at 5 to 57 Hertz, and its operating shock is 30G.



Manufacturer information

Allen-Bradley, a brand of Rockwell Automation, specializes in manufacturing industrial automation equipment. The product range includes programmable logic controllers (PLCs), motion control systems, safety devices, motor control equipment, automation software, and HMI panels. Allen-Bradley products are known for their reliability and integration with other systems.

Check Out These Related Products

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)