1756-OA16I | Allen-Bradley ControlLogix Isolated Output Module 74-265V AC 16-Ch
1756-OA16I | Allen-Bradley ControlLogix Isolated Output Module 74-265V AC 16-Ch
Part #: 1756-OA16I Manufactured by: Allen-Bradley

1756-OA16I | Allen-Bradley ControlLogix Isolated Output Module 74-265V AC 16-Ch

Regular price
$922.00
Sale price
$922.00
Regular price
Never Used Surplus
25 in Stock
Product Overview
Allen Bradley ControlLogix Isoloated AC Output Module with 16 Points Individually Isolated Outputs
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
Product comes with IQElectro 2-Year Warranty
Warranty for item #: 1756-OA16I
IQElectro International provides a 2-year warranty on every product we offer. Our complimentary 2-year warranty ensures that every IQElectro purchase is a trustworthy and reliable investment in the future of your company.
IQElectro is NOT an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.
1756-OA16I | Allen-Bradley ControlLogix Isolated Output Module 74-265V AC 16-Ch
    1756-OA16I | Allen-Bradley ControlLogix Isolated Output Module 74-265V AC 16-Ch
1756-OA16I | Allen-Bradley ControlLogix Isolated Output Module 74-265V AC 16-Ch
Return/Exchange within 30-Days.
If any product is damaged upon delivery, you may request an Exchange or Refund within 30 days of receiving your order.
2-3-Day Free Shipping
"IQElectro provides free shipping within 2-3 days from the moment the order is placed on our website.

Product Description P/N: 1756-OA16I

Description / Specifications

Description 

The Allen-Bradley 1756-OA16I is a 1756 ControlLogix Discrete AC output module. This module features Sixteen (16) individually isolated AC output channels in each channel. It delivers 120 VAC / 240 VAC nominal voltage output within voltage range of 74-265 VAC, 47-63 Hz. It has continuous output current per point of 2 A @ 30 °C (86 °F) linear derating and 1 A @ 60 °C (140 °F) linear derating.

 

Technical Specifications 

 

Brand Allen-Bradley
Series 1756 ControlLogix
Part Number 1756-OA16I
Manufacturer Rockwell Automation
Continuous current per module, max 5 A @ 30 °C (86 °F) linear derating; 4 A @ 60 °C (140 °F) linear derating
Continuous current per point 2 A @ 30 °C (86 °F) linear derating; 1 A @ 60 °C (140 °F) linear derating
Backplane Current at 5.1 Volts 225 mA
OFF state leakage current 3 mA per point
Output Delay Time, OFF to ON 9.3 ms @ 60 Hz; 11 ms @ 50 Hz
Output Voltage 120/240 VAC output
No. of Outputs Sixteen (16) isolated outputs
Module Type Digital AC Output Module
Operating Voltage Range 74-265 VAC
Outputs 16 Points Individually Isolated
Voltage 120-240 Volts AC
Maximum Output Current Rating-Point 2 Amps at 30 degrees Celsius, 1 Amp at 60 degrees Celsius
Maximum Output Current Rating-Module 5 Amps at 30 degrees Celsius, 4 Amps at 60 degrees Celsius
Power Dissipation (Max) 5.5 Watts at 60 degrees Celsius
Backplane Current at 5 Volts 300 milliamps
Backplane Current at 24 Volts 3 milliamps
Removeable Terminal Block(s) 1756-TBCH, 1756-TBS6H
Isolation Voltage 50 Volts Continuous
Enclosure None

  

 

Information About 1756-OA16I

The Allen-Bradley 1756-OA16I is a Sixteen (16) channel discrete output module from the ControlLogix product family. This module delivers an output voltage range of 75-265VAC with frequency of 47-63 Hz while the nominal voltage output is 120 / 240VAC and frequency of 50/60 Hz.

The Allen-Bradley 1756-OA16I requires use of Removable Terminal Block (RTB) to provide wiring connections to the electrical loads connected to each of the module’s output channels. Compatible terminal blocks are 1756-TBCH and 1756-TBS6H. Each channel of this module has an output delay time of 9.3 ms @ 60 Hz and 11 ms @ 50 Hz, both for Off to On transition and 9.3 ms @ 60 Hz and 11 ms @ 50 Hz for On to Off transition. This moduel has a current draw of 300 mA at 5.1 VDC and 2.5 mA at 24VDC while the total backplane power requirement 1.59 Watts.

The 1756-OA16I is a single slot module that is mounted to any 1756 chassis. Compatible chassis are 1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17. This module may also be installed in the local rack, along the ControlLogix controllers or to a remote I/O rack with a 1756 Communication adapter.

The 1756-OA16I supports configuration of fault mode per point. Configurable states are Hold last state, On or Off where Off is default. It also permits configuration of output state during program mode with configurable settings are Hold last state, On or Off where Off is default. This module is not provided with internal fusing however, isolation voltage is present to this module with rating of 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output.

Its operational voltage ranges between 74 and 265V AC at 47-63 Hz, and exhibits an output signal delay time of 9.3 ms at 60Hz and one of 11ms at 50Hz for both ON to OFF and OFF to ON. The 1756-OA16I has a backplane current draw of 300mA at 5.1V and 2.5A at 24V and an aggregate backplane power of 1.59W. It has a thermal dissipation of 18.76 BTU/hr and dissipates 5.5W at 60 °C (140 °F). The 1756-OA16I has a leakage current of 3mA per point and in the ON state, it has a peak drop voltage of 1.5V at 2A and 6V at a load current of <50mA. The maximum current on each output point is 2A at 30 °C and 1A at 60 °C and the aggregate current on the output module is 5A at 30 °C and 4A at 60 °C. The 1756-OA16I has an inrush current of 20A for 43ms per output point, repeatable every 2 s at 60 °C, and the lowest current load sustain on each point is 10mA. It has an output signal schedule time of 16.7s, and has an isolation voltage of 250V, using basic insulation tested at 1350V AC for 2s between outputs-to-backplane and output-to-output. It has a single width slot and its RTB keying is user-defined. The 1756-OA16I has an open-style enclosure and is designated the T4A temperature code. Its operational temperature ranges between 0 and 60 °C at 5-95% non-condensing humidity and it has a maximum operational shock of 30G.



Manufacturer information

Allen‑Bradley components, integrated control and information solutions are built for demanding industrial applications. We integrate control and information across the enterprise to make you as productive as possible.

Warrany image

IQElectro 2 Year Warranty

IQElectro offers a 2-Year Warranty on all our products. This complimentary two-year warranty ensures that every purchase from IQElectro is a secure investment in the future of your company.
Warranty Terms and Conditions
warningIQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses. Some hardware products may contain software and firmware and may not be legally operated without first obtaining an appropriate license from the manufacturer. IQElectro makes no representation as to whether a product will or will not have software or firmware and, if it does, whether the software or firmware is the revision level that you need for your application. IQElectro also makes no representations as to your ability or right to download or otherwise obtain software or firmware for the product from the Original Manufacturer, its distributors, or any other source. IQElectro also makes no representations as to your right to install any such software or firmware on the product. IQElectro will not obtain or supply software or firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing software or firmware. Customer acknowledges and agrees that IQElectro DOES NOT provide any software, firmware, operating system, or right-to-use licenses with the products it sells. Customers understand and agree that proper software (firmware) licensing, maintenance, and upgrades are subject to the applicable manufacturer's Licensing Agreement or similar document. Disclaimer Policy.
Description / Specifications

Description 

The Allen-Bradley 1756-OA16I is a 1756 ControlLogix Discrete AC output module. This module features Sixteen (16) individually isolated AC output channels in each channel. It delivers 120 VAC / 240 VAC nominal voltage output within voltage range of 74-265 VAC, 47-63 Hz. It has continuous output current per point of 2 A @ 30 °C (86 °F) linear derating and 1 A @ 60 °C (140 °F) linear derating.

 

Technical Specifications 

 

Brand Allen-Bradley
Series 1756 ControlLogix
Part Number 1756-OA16I
Manufacturer Rockwell Automation
Continuous current per module, max 5 A @ 30 °C (86 °F) linear derating; 4 A @ 60 °C (140 °F) linear derating
Continuous current per point 2 A @ 30 °C (86 °F) linear derating; 1 A @ 60 °C (140 °F) linear derating
Backplane Current at 5.1 Volts 225 mA
OFF state leakage current 3 mA per point
Output Delay Time, OFF to ON 9.3 ms @ 60 Hz; 11 ms @ 50 Hz
Output Voltage 120/240 VAC output
No. of Outputs Sixteen (16) isolated outputs
Module Type Digital AC Output Module
Operating Voltage Range 74-265 VAC
Outputs 16 Points Individually Isolated
Voltage 120-240 Volts AC
Maximum Output Current Rating-Point 2 Amps at 30 degrees Celsius, 1 Amp at 60 degrees Celsius
Maximum Output Current Rating-Module 5 Amps at 30 degrees Celsius, 4 Amps at 60 degrees Celsius
Power Dissipation (Max) 5.5 Watts at 60 degrees Celsius
Backplane Current at 5 Volts 300 milliamps
Backplane Current at 24 Volts 3 milliamps
Removeable Terminal Block(s) 1756-TBCH, 1756-TBS6H
Isolation Voltage 50 Volts Continuous
Enclosure None

  

 

Information About 1756-OA16I

The Allen-Bradley 1756-OA16I is a Sixteen (16) channel discrete output module from the ControlLogix product family. This module delivers an output voltage range of 75-265VAC with frequency of 47-63 Hz while the nominal voltage output is 120 / 240VAC and frequency of 50/60 Hz.

The Allen-Bradley 1756-OA16I requires use of Removable Terminal Block (RTB) to provide wiring connections to the electrical loads connected to each of the module’s output channels. Compatible terminal blocks are 1756-TBCH and 1756-TBS6H. Each channel of this module has an output delay time of 9.3 ms @ 60 Hz and 11 ms @ 50 Hz, both for Off to On transition and 9.3 ms @ 60 Hz and 11 ms @ 50 Hz for On to Off transition. This moduel has a current draw of 300 mA at 5.1 VDC and 2.5 mA at 24VDC while the total backplane power requirement 1.59 Watts.

The 1756-OA16I is a single slot module that is mounted to any 1756 chassis. Compatible chassis are 1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17. This module may also be installed in the local rack, along the ControlLogix controllers or to a remote I/O rack with a 1756 Communication adapter.

The 1756-OA16I supports configuration of fault mode per point. Configurable states are Hold last state, On or Off where Off is default. It also permits configuration of output state during program mode with configurable settings are Hold last state, On or Off where Off is default. This module is not provided with internal fusing however, isolation voltage is present to this module with rating of 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output.

Its operational voltage ranges between 74 and 265V AC at 47-63 Hz, and exhibits an output signal delay time of 9.3 ms at 60Hz and one of 11ms at 50Hz for both ON to OFF and OFF to ON. The 1756-OA16I has a backplane current draw of 300mA at 5.1V and 2.5A at 24V and an aggregate backplane power of 1.59W. It has a thermal dissipation of 18.76 BTU/hr and dissipates 5.5W at 60 °C (140 °F). The 1756-OA16I has a leakage current of 3mA per point and in the ON state, it has a peak drop voltage of 1.5V at 2A and 6V at a load current of <50mA. The maximum current on each output point is 2A at 30 °C and 1A at 60 °C and the aggregate current on the output module is 5A at 30 °C and 4A at 60 °C. The 1756-OA16I has an inrush current of 20A for 43ms per output point, repeatable every 2 s at 60 °C, and the lowest current load sustain on each point is 10mA. It has an output signal schedule time of 16.7s, and has an isolation voltage of 250V, using basic insulation tested at 1350V AC for 2s between outputs-to-backplane and output-to-output. It has a single width slot and its RTB keying is user-defined. The 1756-OA16I has an open-style enclosure and is designated the T4A temperature code. Its operational temperature ranges between 0 and 60 °C at 5-95% non-condensing humidity and it has a maximum operational shock of 30G.



Manufacturer information

Allen‑Bradley components, integrated control and information solutions are built for demanding industrial applications. We integrate control and information across the enterprise to make you as productive as possible.

Check Out These Related Products