The Allen-Bradley 1757-SRM ProcessLogix and ControlLogix System Redundancy Module is part of a special machine system desi...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
Product comes with IQElectro 2-Year Warranty
Warranty for item #: 1757-SRM
IQElectro International provides a 2-year warranty on every product we offer. Our complimentary 2-year warranty ensures that every IQElectro purchase is a trustworthy and reliable investment in the future of your company.
IQElectro is NOT an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.
1757-SRM | Allen-Bradley ProcessLogix & ControlLogix System Redundancy Module
    1757-SRM | Allen-Bradley ProcessLogix & ControlLogix System Redundancy Module
1757-SRM | Allen-Bradley ProcessLogix & ControlLogix System Redundancy Module
Return/Exchange within 30-Days.
If any product is damaged upon delivery, you may request an Exchange or Refund within 30 days of receiving your order.
2-3-Day Free Shipping
"IQElectro provides free shipping within 2-3 days from the moment the order is placed on our website.

Product Description P/N: 1757-SRM

Description / Specifications

Description 

The Allen-Bradley 1757-SRM is a ProcessLogix and ControlLogix System Redundancy Module. This module enables Controller Redundancy by pairing with another 1756-SRM from another ControlLogix chassis. This module is a Two (2) slot module with integrated Fiber Optic port compatible for 62.5/125 micron multi-mode fiber-optic cable with SC connector.

 

Technical Specifications 

 

Brand Allen-Bradley
Manufacturer Rockwell Automation
Part Number 1757-SRM
Series ControlLogix; ProcessLogix
Backplane current 0.160 A at 24V DC
Mounting ControlLogix chassis
Module Type System Redundancy Module
Connector SC Type
Enclosure type rating None (open-style)
Cable Type 62.5/125-micron multi-mode fiber-optic cable
Power dissipation, max 11.28 W
Supported Controllers Logix 5560
Thermal dissipation, max 38.49 BTU/hr
Slot Width 2
Connector Cables 1757-SRC1, 1 m (3.28 ft); 1757-SRC3, 3 m (9.84 ft); 1757- SRC10, 10 m (32.81 ft); 1757-SRC50, 50 m (164.04 ft); 1757- SRC100, 100 m (328.08 ft)
Temperature, operating 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit)
Wavelength 1300 nm
Channels 1 (transmit and receive fiber)
Dimensions 14.5 x 7 x 14 cm (5.71 x 2.76 x 5.51 in.)
Operating Temperature 32-140 Fahrenheit (0-60 Celsius)
Enclosure None

  

 

Information About 1757-SRM

The 1757-SRM is an Allen-Bradley ProcessLogix and ControlLogix module that is used for implementing controller redundancy to increase a process system availability. This is done by employing a secondary controller synchronized with a primary controller installed on Two (2) different ControlLogix chassis.

When implementing a redundant controller system, Two (2) identical ControlLogix chassis must be installed. The chassis size, the modules installed and positioning, System power supply and module revisions should match each other. This qualifies the redundant controller setup. One of the chassis will be termed as primary while the other is secondary chassis.

The 1757-SRM features a Fiber Optic port where a 62.5/125-micron multi-mode fiber-optic cable with SC connector is connected. The other end of the cable connects to the partner 1757-SRM installed on the other ControlLogix chassis. This cable serves as the synchronization link of the modules and the entire secondary rack.

The 1757-SRM is a Two (2) slot module. It has module status display that indicates text codes that represent the module operational status. The PRI LED inform the user which of the chassis within the pair operates as the primary chassis. The COM LED represents the communication and synchronization status. The Health status LED indicates if the module is performing self-test, experienced critical failure or operating normally.

The 1757-SRM is compatible with ControlLogix chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, or 1756-A17 and System Power Supplies 1756-PA72, 1756-PA75, 1756-PB72, or 1756-PB75. For 1756-A4, recommended installation slot is 1 or 2; 1756-A7 is slot 4 or 5; 1756-A10 is slot 5 or 6; 1756-A13 is slot 4 or 5 and 1756-A17 is slot 5 or 6.

The Allen-Bradley 1757-SRM ProcessLogix and ControlLogix System Redundancy Module is a solid-state device that is employed in critical industrial applications that should not be stopped under any circumstances in order to provide a redundancy system by using an identical pair of PLCs to guarantee operation at all times. The 1757-SRM redundancy module is designed for installation in any free slot of a ControlLogix chassis but predefining the order of the cards to install in each ControlLogix slot is recommended. Both PLC systems, called the primary and secondary PLC systems, should be identical for the redundancy system to work appropriately.

The Allen-Bradley 1757-SRM ProcessLogix and ControlLogix System Redundancy Modules installed in primary and secondary PLC chassis will need to be interconnected by using a 1757-SRCxx Fiber-optic Cable. The length of the cable can be 1 meter (3 feet), 3 meters (9 feet), 10 meters (30 feet), 50 meters (150 feet), or 100 meters (300 feet). Once both chassis are assembled and connected, it can be designated which one will be the primary chassis and which will be the secondary chassis. If they are the same, then redundant control will be guaranteed and in case of a failure in the first PLC, the second one will take over the application process and signal an alarm to inform the final users of the event without stopping the critical process in the meantime.





Manufacturer information

Allen‑Bradley components, integrated control and information solutions are built for demanding industrial applications. We integrate control and information across the enterprise to make you as productive as possible.

Warrany image

IQElectro 2 Year Warranty

IQElectro offers a 2-Year Warranty on all our products. This complimentary two-year warranty ensures that every purchase from IQElectro is a secure investment in the future of your company.
Warranty Terms and Conditions
warningIQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses. Some hardware products may contain software and firmware and may not be legally operated without first obtaining an appropriate license from the manufacturer. IQElectro makes no representation as to whether a product will or will not have software or firmware and, if it does, whether the software or firmware is the revision level that you need for your application. IQElectro also makes no representations as to your ability or right to download or otherwise obtain software or firmware for the product from the Original Manufacturer, its distributors, or any other source. IQElectro also makes no representations as to your right to install any such software or firmware on the product. IQElectro will not obtain or supply software or firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing software or firmware. Customer acknowledges and agrees that IQElectro DOES NOT provide any software, firmware, operating system, or right-to-use licenses with the products it sells. Customers understand and agree that proper software (firmware) licensing, maintenance, and upgrades are subject to the applicable manufacturer's Licensing Agreement or similar document. Disclaimer Policy.
Description / Specifications

Description 

The Allen-Bradley 1757-SRM is a ProcessLogix and ControlLogix System Redundancy Module. This module enables Controller Redundancy by pairing with another 1756-SRM from another ControlLogix chassis. This module is a Two (2) slot module with integrated Fiber Optic port compatible for 62.5/125 micron multi-mode fiber-optic cable with SC connector.

 

Technical Specifications 

 

Brand Allen-Bradley
Manufacturer Rockwell Automation
Part Number 1757-SRM
Series ControlLogix; ProcessLogix
Backplane current 0.160 A at 24V DC
Mounting ControlLogix chassis
Module Type System Redundancy Module
Connector SC Type
Enclosure type rating None (open-style)
Cable Type 62.5/125-micron multi-mode fiber-optic cable
Power dissipation, max 11.28 W
Supported Controllers Logix 5560
Thermal dissipation, max 38.49 BTU/hr
Slot Width 2
Connector Cables 1757-SRC1, 1 m (3.28 ft); 1757-SRC3, 3 m (9.84 ft); 1757- SRC10, 10 m (32.81 ft); 1757-SRC50, 50 m (164.04 ft); 1757- SRC100, 100 m (328.08 ft)
Temperature, operating 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit)
Wavelength 1300 nm
Channels 1 (transmit and receive fiber)
Dimensions 14.5 x 7 x 14 cm (5.71 x 2.76 x 5.51 in.)
Operating Temperature 32-140 Fahrenheit (0-60 Celsius)
Enclosure None

  

 

Information About 1757-SRM

The 1757-SRM is an Allen-Bradley ProcessLogix and ControlLogix module that is used for implementing controller redundancy to increase a process system availability. This is done by employing a secondary controller synchronized with a primary controller installed on Two (2) different ControlLogix chassis.

When implementing a redundant controller system, Two (2) identical ControlLogix chassis must be installed. The chassis size, the modules installed and positioning, System power supply and module revisions should match each other. This qualifies the redundant controller setup. One of the chassis will be termed as primary while the other is secondary chassis.

The 1757-SRM features a Fiber Optic port where a 62.5/125-micron multi-mode fiber-optic cable with SC connector is connected. The other end of the cable connects to the partner 1757-SRM installed on the other ControlLogix chassis. This cable serves as the synchronization link of the modules and the entire secondary rack.

The 1757-SRM is a Two (2) slot module. It has module status display that indicates text codes that represent the module operational status. The PRI LED inform the user which of the chassis within the pair operates as the primary chassis. The COM LED represents the communication and synchronization status. The Health status LED indicates if the module is performing self-test, experienced critical failure or operating normally.

The 1757-SRM is compatible with ControlLogix chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, or 1756-A17 and System Power Supplies 1756-PA72, 1756-PA75, 1756-PB72, or 1756-PB75. For 1756-A4, recommended installation slot is 1 or 2; 1756-A7 is slot 4 or 5; 1756-A10 is slot 5 or 6; 1756-A13 is slot 4 or 5 and 1756-A17 is slot 5 or 6.

The Allen-Bradley 1757-SRM ProcessLogix and ControlLogix System Redundancy Module is a solid-state device that is employed in critical industrial applications that should not be stopped under any circumstances in order to provide a redundancy system by using an identical pair of PLCs to guarantee operation at all times. The 1757-SRM redundancy module is designed for installation in any free slot of a ControlLogix chassis but predefining the order of the cards to install in each ControlLogix slot is recommended. Both PLC systems, called the primary and secondary PLC systems, should be identical for the redundancy system to work appropriately.

The Allen-Bradley 1757-SRM ProcessLogix and ControlLogix System Redundancy Modules installed in primary and secondary PLC chassis will need to be interconnected by using a 1757-SRCxx Fiber-optic Cable. The length of the cable can be 1 meter (3 feet), 3 meters (9 feet), 10 meters (30 feet), 50 meters (150 feet), or 100 meters (300 feet). Once both chassis are assembled and connected, it can be designated which one will be the primary chassis and which will be the secondary chassis. If they are the same, then redundant control will be guaranteed and in case of a failure in the first PLC, the second one will take over the application process and signal an alarm to inform the final users of the event without stopping the critical process in the meantime.





Manufacturer information

Allen‑Bradley components, integrated control and information solutions are built for demanding industrial applications. We integrate control and information across the enterprise to make you as productive as possible.

Check Out These Related Products