1762-OW8 | Allen-Bradley MicroLogix 8-Point AC/DC Relay Output Module, DIN Rail Mount
- Regular price
- $129.00
- Sale price
- $129.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: 1762-OW8
Description
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Allen-Bradley |
| Category | PLCs / Machine Control |
| Part Number | 1762-OW8 |
| Subcategory | Relay Output Module |
| Compatible Controllers | MicroLogix 1100, 1200, 1400 |
| Number of Outputs | 8 (relay) |
| Output Type | AC/DC Normally Open Relay |
| Voltage Range | 5–265 VAC, 5–125 VDC |
| Max Current per Point | 2.5 A |
| Number of Groups | 2 groups (4 channels each) |
| Signal Delay | 10 ms |
| Power Supply Distance Rating | 6 modules |
| Mounting Type | DIN rail / panel mount |
| Heat Dissipation | 2.9 W |
| Operating Temperature | 0–55°C (32–131°F) |
| Wire Size | 14–24 AWG (two wires per terminal) |
| Shipping Weight | 228 g (0.50 lb) |
| UPC | 10612598207265 |
| Environmental Rating | Pollution Degree 2 |
| ESD Protection Requirement | Yes – during storage, installation, operation, and maintenance |
Information About 1762-OW8
The 1762-OW8 module is part of the MicroLogix expansion family and provides eight normally-open relay outputs arranged into two isolated groups of four points each. Its construction includes robust electromechanical relays suitable for switching solenoids, contactors, pilot lights, and general-purpose AC/DC loads. The module supports both DIN rail and panel mounting and adheres to Pollution Degree 2 installation requirements. With a 6-module separation limit from the system power supply and a 10 ms signal delay, the unit integrates seamlessly into MicroLogix architectures. Its operating range of 0–55°C (32–131°F) and compact design make it suitable for small to medium-scale automation applications.
Key Features:
- Eight relay outputs: AC/DC switching capability for diverse load types.
- Wide voltage support: 5–265 VAC and 5–125 VDC operating range.
- Normally open relay contacts: Ideal for general industrial control loads.
- Two isolated groups: Four channels per group for flexible wiring.
- DIN rail or panel mount: Supports multiple installation methods.
- Compatible with MicroLogix controllers: Works with 1100, 1200, and 1400 systems.
- Power supply distance rating: Up to six modules from the power supply.
- 10 ms signal delay: Suitable for typical discrete output applications.
- 2.5 A max per point: Handles moderate inductive and resistive loads.
- Designed for clean, dry environments: Pollution Degree 2 installation rating.
The 1762-OW8 delivers the reliability and precision required for relay-based output switching in MicroLogix automation systems.
Description
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Allen-Bradley |
| Category | PLCs / Machine Control |
| Part Number | 1762-OW8 |
| Subcategory | Relay Output Module |
| Compatible Controllers | MicroLogix 1100, 1200, 1400 |
| Number of Outputs | 8 (relay) |
| Output Type | AC/DC Normally Open Relay |
| Voltage Range | 5–265 VAC, 5–125 VDC |
| Max Current per Point | 2.5 A |
| Number of Groups | 2 groups (4 channels each) |
| Signal Delay | 10 ms |
| Power Supply Distance Rating | 6 modules |
| Mounting Type | DIN rail / panel mount |
| Heat Dissipation | 2.9 W |
| Operating Temperature | 0–55°C (32–131°F) |
| Wire Size | 14–24 AWG (two wires per terminal) |
| Shipping Weight | 228 g (0.50 lb) |
| UPC | 10612598207265 |
| Environmental Rating | Pollution Degree 2 |
| ESD Protection Requirement | Yes – during storage, installation, operation, and maintenance |
Information About 1762-OW8
The 1762-OW8 module is part of the MicroLogix expansion family and provides eight normally-open relay outputs arranged into two isolated groups of four points each. Its construction includes robust electromechanical relays suitable for switching solenoids, contactors, pilot lights, and general-purpose AC/DC loads. The module supports both DIN rail and panel mounting and adheres to Pollution Degree 2 installation requirements. With a 6-module separation limit from the system power supply and a 10 ms signal delay, the unit integrates seamlessly into MicroLogix architectures. Its operating range of 0–55°C (32–131°F) and compact design make it suitable for small to medium-scale automation applications.
Key Features:
- Eight relay outputs: AC/DC switching capability for diverse load types.
- Wide voltage support: 5–265 VAC and 5–125 VDC operating range.
- Normally open relay contacts: Ideal for general industrial control loads.
- Two isolated groups: Four channels per group for flexible wiring.
- DIN rail or panel mount: Supports multiple installation methods.
- Compatible with MicroLogix controllers: Works with 1100, 1200, and 1400 systems.
- Power supply distance rating: Up to six modules from the power supply.
- 10 ms signal delay: Suitable for typical discrete output applications.
- 2.5 A max per point: Handles moderate inductive and resistive loads.
- Designed for clean, dry environments: Pollution Degree 2 installation rating.
The 1762-OW8 delivers the reliability and precision required for relay-based output switching in MicroLogix automation systems.