Product Description P/N: 1SU41001
Description
The 1SU41001 by Reliance Electric is a SP500 Drive, delivering 2.5 AMP output for 1 HP 3-phase motors. Designed for precision and efficiency, it ensures reliable motor control in diverse industrial applications.
Technical Specifications
Brand | Reliance Electric |
Series | SP500 |
Part Number | 1SU41001 |
HP | 1 HP |
Input Voltage | 380-460 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 50/60Hz |
Information About 1SU41001
Reliance Electric manufactures the SP500 drive series, of which 1SU41001 is a part. The rated horsepower for this NEMA 1 (chassis enclosure) drive is 0.25-1.0 HP. The rated voltage is 380-460 VAC. The enclosure size for this drive is size B. The dimensions of Enclosure B are 301.7 mm (11.88 in) (H) x 160.1 mm (6.3 in) (D) x 222.3 mm (8.75 in) (W). The weight of enclosure B is 5.4 kg (12 lb).
A number of fault codes help the user identify faults on the drive. nCL is the code for the network comm loss fault. This fault is caused when communications with the AutoMax network have been lost. In order to correct this fault, first check the network cabling from the network master to the network option board. Then check that the network master is operating correctly. nld is the code for the Identification Request not yet performed fault. This fault is caused when the drive has started but the Identification Result = Zero. In order to correct this fault, reset the fault, perform another Identification request, and restart the drive. OCA is the code for the overcurrent at acceleration fault. This fault is caused by either an overcurrent condition that occurred while the drive was accelerating, or a too-short acceleration time. In order to correct this fault, increase the acceleration time. OCb is the code for the overcurrent at DC braking fault. This fault is caused by a DC voltage that is too high. In order to correct this fault, check parameters H.006 and H.007.
Manufacturer information
Reliance Electric, a pioneering electrical equipment manufacturer, was founded in 1904. Acquired by Rockwell Automation, it specialized in motors, drives, and industrial automation solutions. Known for innovation, Reliance played a key role in advancing industrial technology.
Description
The 1SU41001 by Reliance Electric is a SP500 Drive, delivering 2.5 AMP output for 1 HP 3-phase motors. Designed for precision and efficiency, it ensures reliable motor control in diverse industrial applications.
Technical Specifications
Brand | Reliance Electric |
Series | SP500 |
Part Number | 1SU41001 |
HP | 1 HP |
Input Voltage | 380-460 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 50/60Hz |
Information About 1SU41001
Reliance Electric manufactures the SP500 drive series, of which 1SU41001 is a part. The rated horsepower for this NEMA 1 (chassis enclosure) drive is 0.25-1.0 HP. The rated voltage is 380-460 VAC. The enclosure size for this drive is size B. The dimensions of Enclosure B are 301.7 mm (11.88 in) (H) x 160.1 mm (6.3 in) (D) x 222.3 mm (8.75 in) (W). The weight of enclosure B is 5.4 kg (12 lb).
A number of fault codes help the user identify faults on the drive. nCL is the code for the network comm loss fault. This fault is caused when communications with the AutoMax network have been lost. In order to correct this fault, first check the network cabling from the network master to the network option board. Then check that the network master is operating correctly. nld is the code for the Identification Request not yet performed fault. This fault is caused when the drive has started but the Identification Result = Zero. In order to correct this fault, reset the fault, perform another Identification request, and restart the drive. OCA is the code for the overcurrent at acceleration fault. This fault is caused by either an overcurrent condition that occurred while the drive was accelerating, or a too-short acceleration time. In order to correct this fault, increase the acceleration time. OCb is the code for the overcurrent at DC braking fault. This fault is caused by a DC voltage that is too high. In order to correct this fault, check parameters H.006 and H.007.
Manufacturer information
Reliance Electric, a pioneering electrical equipment manufacturer, was founded in 1904. Acquired by Rockwell Automation, it specialized in motors, drives, and industrial automation solutions. Known for innovation, Reliance played a key role in advancing industrial technology.