Product Description P/N: 45C630
Description
The 45C63 output module is designed as part of the DCS 5000 series, featuring dual output functionality with a nominal DC voltage of 24 Volts, operable within a working voltage range of 15 Volts to 40 Volts. The module can withstand a peak voltage of up to 100 Volts due to overshoot. Its output circuit supports a maximum continuous output current of 2 Amps, with a maximum on-state Voltage of 0.8 Volts and a maximum off-state leakage current at peak Voltage of 1 milliAmp. Additionally, the module can handle a maximum inductive load energy of 6.5 Joules and has a power dissipation of 2.6 Watts at maximum temperature and current.
Technical Specifications
Part # |
45C630 |
Category |
Controls & Indicators |
Subcategory |
Timer/Counter |
Type |
Counter |
Input Method |
Thumbwheel Switch |
Input Type |
Analog |
Mounting Style |
Panel Mount |
Information About 45C630
The 45C63 output module features a nominal DC voltage of 24 Volts, with a working voltage range spanning from 15 Volts to 40 Volts. Additionally, it allows for a peak voltage overshoot of up to 100 Volts. The output circuit of the 45C63 module is designed to deliver a maximum continuous output current of 2 Amps, with a maximum on-state voltage of 0.8 Volts and a maximum off-state leakage current of 1 milliAmp at peak voltage. Furthermore, it supports a maximum inductive load energy of 6.5 Joules and exhibits a power dissipation of 2.6 Watts at maximum temperature and current.
To ensure proper utilization of the 45C63 output module, it should be securely plugged into an appropriate I/O rail, such as the AutoMax 45C1 model. Following installation, it is imperative to maintain favorable environmental conditions in the operational area. The module is designed to function within an operating temperature range of 32 to 140 degrees Fahrenheit, while the storage temperature should be maintained between -4 to 185 degrees Fahrenheit. Additionally, the humidity level should fall within the range of 5% to 90% non-condensing. These environmental parameters help to optimize the performance and longevity of the 45C63 output module in various industrial applications.
Manufacturer information
Reliance Electric, a pioneering electrical equipment manufacturer, was founded in 1904. Acquired by Rockwell Automation, it specialized in motors, drives, and industrial automation solutions. Known for innovation, Reliance played a key role in advancing industrial technology.
IQElectro 2 Year Warranty
IQElectro offers a 2-Year Warranty on all our products. This complimentary two-year warranty ensures that every purchase from IQElectro is a secure investment in the future of your company.Warranty Terms and Conditions
Description
The 45C63 output module is designed as part of the DCS 5000 series, featuring dual output functionality with a nominal DC voltage of 24 Volts, operable within a working voltage range of 15 Volts to 40 Volts. The module can withstand a peak voltage of up to 100 Volts due to overshoot. Its output circuit supports a maximum continuous output current of 2 Amps, with a maximum on-state Voltage of 0.8 Volts and a maximum off-state leakage current at peak Voltage of 1 milliAmp. Additionally, the module can handle a maximum inductive load energy of 6.5 Joules and has a power dissipation of 2.6 Watts at maximum temperature and current.
Technical Specifications
Part # |
45C630 |
Category |
Controls & Indicators |
Subcategory |
Timer/Counter |
Type |
Counter |
Input Method |
Thumbwheel Switch |
Input Type |
Analog |
Mounting Style |
Panel Mount |
Information About 45C630
The 45C63 output module features a nominal DC voltage of 24 Volts, with a working voltage range spanning from 15 Volts to 40 Volts. Additionally, it allows for a peak voltage overshoot of up to 100 Volts. The output circuit of the 45C63 module is designed to deliver a maximum continuous output current of 2 Amps, with a maximum on-state voltage of 0.8 Volts and a maximum off-state leakage current of 1 milliAmp at peak voltage. Furthermore, it supports a maximum inductive load energy of 6.5 Joules and exhibits a power dissipation of 2.6 Watts at maximum temperature and current.
To ensure proper utilization of the 45C63 output module, it should be securely plugged into an appropriate I/O rail, such as the AutoMax 45C1 model. Following installation, it is imperative to maintain favorable environmental conditions in the operational area. The module is designed to function within an operating temperature range of 32 to 140 degrees Fahrenheit, while the storage temperature should be maintained between -4 to 185 degrees Fahrenheit. Additionally, the humidity level should fall within the range of 5% to 90% non-condensing. These environmental parameters help to optimize the performance and longevity of the 45C63 output module in various industrial applications.