Product Description P/N: 509-BAD
Description
The Allen-Bradley 509-BAD Starter is a non-reversing starter designed for industrial applications. It is categorized as Size 1 and adheres to NEMA 1 General Purpose standards. This three-phase starter features eutectic overload protection and lacks a fuse cover. It operates at a standard capacity and is compatible with 115-120V 60Hz power sources. Additionally, it is suitable for controlling incandescent loads.
Technical Specifications
Part # |
509-BAD |
Category |
Contactors & Starters |
Subcategory |
Starter |
Phases |
3 Phase |
NEMA Size |
NEMA 1 |
Enclosure Code |
Type 1 General Purpose |
Control Voltage |
110/120V 50/60 Hz |
Overload Relay Type |
Eutectic Alloy |
Full Load Amps |
Eutectic Overload - Select a heater element based on trip class and Motor FLA |
Load Voltage |
115…575 (V) |
Continuous Current Rating |
27 (A) |
Service Limit Current Rating |
32 (A) |
Maximum Hp Rating (Non-plugging and non-jogging duty) Single-Phase |
- (Hp) |
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase |
10 (Hp) |
Maximum Circuit Closing Inrush Current, Peak Including Offset |
288 (A) |
Mechanical Life |
10 (Millions of Operations) |
Maximum Number of Auxiliary Contacts |
8 |
Pick-up Operating Time (Average) |
22 (ms) |
Drop-out Operating Time (Average) |
14 (ms) |
Wire size for Power Terminals |
14…8 (AWG) |
Required Torque |
20 (lb•in) |
Type of Power Terminal |
Saddle or Wire Clamps |
Operating Position |
Vertical |
Temperature Range |
-13…+149°F(-25…+65°C) |
Altitude |
10,000 (feet before derating) |
Corrosion-Resistance |
All metal parts are treated for corrosion-resistance |
Information About 509-BAD
The Allen-Bradley 509-BAD Starter is a non-reversing starter designed for industrial applications. Classified as Size 1 and conforming to NEMA 1 General Purpose standards, it is suitable for three-phase systems. Equipped with eutectic overload protection, it lacks a fuse cover and operates at standard capacity. Its compatibility extends to power sources of 115-120V operating at 60Hz frequency. Additionally, it is capable of controlling incandescent loads, offering versatility in various industrial settings.
Manufacturer information
Allen-Bradley, a brand of Rockwell Automation, specializes in manufacturing industrial automation equipment. The product range includes programmable logic controllers (PLCs), motion control systems, safety devices, motor control equipment, automation software, and HMI panels. Allen-Bradley products are known for their reliability and integration with other systems.
Description
The Allen-Bradley 509-BAD Starter is a non-reversing starter designed for industrial applications. It is categorized as Size 1 and adheres to NEMA 1 General Purpose standards. This three-phase starter features eutectic overload protection and lacks a fuse cover. It operates at a standard capacity and is compatible with 115-120V 60Hz power sources. Additionally, it is suitable for controlling incandescent loads.
Technical Specifications
Part # |
509-BAD |
Category |
Contactors & Starters |
Subcategory |
Starter |
Phases |
3 Phase |
NEMA Size |
NEMA 1 |
Enclosure Code |
Type 1 General Purpose |
Control Voltage |
110/120V 50/60 Hz |
Overload Relay Type |
Eutectic Alloy |
Full Load Amps |
Eutectic Overload - Select a heater element based on trip class and Motor FLA |
Load Voltage |
115…575 (V) |
Continuous Current Rating |
27 (A) |
Service Limit Current Rating |
32 (A) |
Maximum Hp Rating (Non-plugging and non-jogging duty) Single-Phase |
- (Hp) |
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase |
10 (Hp) |
Maximum Circuit Closing Inrush Current, Peak Including Offset |
288 (A) |
Mechanical Life |
10 (Millions of Operations) |
Maximum Number of Auxiliary Contacts |
8 |
Pick-up Operating Time (Average) |
22 (ms) |
Drop-out Operating Time (Average) |
14 (ms) |
Wire size for Power Terminals |
14…8 (AWG) |
Required Torque |
20 (lb•in) |
Type of Power Terminal |
Saddle or Wire Clamps |
Operating Position |
Vertical |
Temperature Range |
-13…+149°F(-25…+65°C) |
Altitude |
10,000 (feet before derating) |
Corrosion-Resistance |
All metal parts are treated for corrosion-resistance |
Information About 509-BAD
The Allen-Bradley 509-BAD Starter is a non-reversing starter designed for industrial applications. Classified as Size 1 and conforming to NEMA 1 General Purpose standards, it is suitable for three-phase systems. Equipped with eutectic overload protection, it lacks a fuse cover and operates at standard capacity. Its compatibility extends to power sources of 115-120V operating at 60Hz frequency. Additionally, it is capable of controlling incandescent loads, offering versatility in various industrial settings.
Manufacturer information
Allen-Bradley, a brand of Rockwell Automation, specializes in manufacturing industrial automation equipment. The product range includes programmable logic controllers (PLCs), motion control systems, safety devices, motor control equipment, automation software, and HMI panels. Allen-Bradley products are known for their reliability and integration with other systems.