Product Description P/N: ACH550-VCR-023A-4+F267
Description
The ABB ACH550-VCR-023A-4+F267 is a 15 HP HVAC variable frequency drive package equipped with an integrated 3-contactor bypass assembly for continuous building climate control. Operating on 380 to 480 VAC three-phase power, it modulates fan and pump speeds while providing seamless mechanical failover to utility line power. Built into a UL Type 1 enclosure, this drive maximizes facility energy savings and guarantees uninterrupted critical airflow.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand |
ABB |
| Category | Motor Controls |
| Part Number |
ACH550-VCR-023A-4+F267 |
| Subcategory | Variable Frequency Drives with Bypass |
| Drive Series | ACH550 E-Clipse Bypass |
| Horsepower | 15 HP |
| Output Current |
23 Amps |
| Input Voltage | 380 to 480 VAC (3-Phase) |
| Enclosure Rating | UL Type 1 (NEMA 1) |
| Weight | 95.0 lbs |
Information About ACH550-VCR-023A-4+F267
The ACH550-VCR-023A-4+F267 belongs to the trusted ACH550 E-Clipse bypass drive series, rated for 23 Amps continuous output current. The factory-integrated +F267 bypass package includes an input disconnect switch, motor overload protection, and three heavy-duty contactors that allow operators to isolate the VFD for servicing while running the motor directly across the line. Featuring native BACnet, Modbus, and N2 communications alongside a patented swinging choke for harmonic reduction, it integrates effortlessly into commercial building automation systems.
Key Features:
-
Integrated 3-Contactor Bypass: Allows safe drive isolation and uninterrupted motor operation on utility line power during maintenance.
-
15 HP HVAC Output: Delivers 23 Amps at 380-480 VAC 3-phase to efficiently control commercial air handlers, fans, and hydronic pumps.
-
Native Building Protocols: Includes embedded BACnet, Modbus RTU, and N2 communications for direct BMS integration without external gateways.
-
Harmonic Mitigation: Incorporates ABB's patented swinging choke to suppress electrical harmonics and protect facility power quality.
-
Intuitive HVAC Control Panel: Features a backlit plain-English display with dedicated Hand-Off-Auto keys and diagnostic assistants.
-
UL Type 1 Enclosure: Provides a clean, self-contained wall-mount cabinet suitable for commercial mechanical rooms.
The ACH550-VCR-023A-4+F267 delivers the energy efficiency and bypass redundancy required for critical commercial HVAC applications.
Description
The ABB ACH550-VCR-023A-4+F267 is a 15 HP HVAC variable frequency drive package equipped with an integrated 3-contactor bypass assembly for continuous building climate control. Operating on 380 to 480 VAC three-phase power, it modulates fan and pump speeds while providing seamless mechanical failover to utility line power. Built into a UL Type 1 enclosure, this drive maximizes facility energy savings and guarantees uninterrupted critical airflow.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand |
ABB |
| Category | Motor Controls |
| Part Number |
ACH550-VCR-023A-4+F267 |
| Subcategory | Variable Frequency Drives with Bypass |
| Drive Series | ACH550 E-Clipse Bypass |
| Horsepower | 15 HP |
| Output Current |
23 Amps |
| Input Voltage | 380 to 480 VAC (3-Phase) |
| Enclosure Rating | UL Type 1 (NEMA 1) |
| Weight | 95.0 lbs |
Information About ACH550-VCR-023A-4+F267
The ACH550-VCR-023A-4+F267 belongs to the trusted ACH550 E-Clipse bypass drive series, rated for 23 Amps continuous output current. The factory-integrated +F267 bypass package includes an input disconnect switch, motor overload protection, and three heavy-duty contactors that allow operators to isolate the VFD for servicing while running the motor directly across the line. Featuring native BACnet, Modbus, and N2 communications alongside a patented swinging choke for harmonic reduction, it integrates effortlessly into commercial building automation systems.
Key Features:
-
Integrated 3-Contactor Bypass: Allows safe drive isolation and uninterrupted motor operation on utility line power during maintenance.
-
15 HP HVAC Output: Delivers 23 Amps at 380-480 VAC 3-phase to efficiently control commercial air handlers, fans, and hydronic pumps.
-
Native Building Protocols: Includes embedded BACnet, Modbus RTU, and N2 communications for direct BMS integration without external gateways.
-
Harmonic Mitigation: Incorporates ABB's patented swinging choke to suppress electrical harmonics and protect facility power quality.
-
Intuitive HVAC Control Panel: Features a backlit plain-English display with dedicated Hand-Off-Auto keys and diagnostic assistants.
-
UL Type 1 Enclosure: Provides a clean, self-contained wall-mount cabinet suitable for commercial mechanical rooms.
The ACH550-VCR-023A-4+F267 delivers the energy efficiency and bypass redundancy required for critical commercial HVAC applications.