ABB TH3364 Heavy-Duty Fusible Safety Disconnect Switch 200A 600VAC 3-Pole NEMA 1
- Regular price
- $1,499.00
- Sale price
- $1,499.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: TH3364
Description
The ABB TH3364 is a heavy-duty fusible safety switch designed for electrical isolation, circuit protection, and equipment disconnect applications in commercial and industrial facilities. ABB part number TH3364 features a 200 A current rating, 600 VAC maximum operating voltage, and a three-pole switching configuration housed in a NEMA 1 indoor enclosure. Its quick-make, quick-break operating mechanism and cover interlock system support controlled switching and maintenance of three-phase electrical equipment.
Technical Specifications
|
Condition |
New/Never Used Surplus |
|
Brand |
ABB / GE Industrial Solutions |
|
Category |
Electrical Distribution & Power Control |
|
Part Number |
TH3364 |
|
Subcategory |
Heavy-Duty Fusible Safety Switches |
|
Product Type |
Heavy-Duty Safety Disconnect Switch |
|
Series |
Heavy Duty |
|
GO Schedule |
S1 |
|
Voltage Rating |
600 VAC |
|
Amperage Rating |
200 A |
|
Number of Poles |
3 |
|
Number of Wires |
3 |
|
Switch Type |
Fusible |
|
Enclosure Rating |
NEMA 1 (Indoor) |
|
Operating Mechanism |
Quick-Make, Quick-Break |
|
Wire Range (Cu/Al) |
2 × 250 |
|
Horsepower Rating, 480 VAC, NEC Standard, 1-Phase |
25 HP |
|
Horsepower Rating, 480 VAC, NEC Standard, 3-Phase |
50 HP |
|
Horsepower Rating, 480 VAC, Time Delay, 1-Phase |
50 HP |
|
Horsepower Rating, 480 VAC, Time Delay, 3-Phase |
125 HP |
|
Horsepower Rating, 600 VAC, NEC Standard, 1-Phase |
30 HP |
|
Horsepower Rating, 600 VAC, NEC Standard, 3-Phase |
60 HP |
|
Horsepower Rating, 600 VAC, Time Delay, 1-Phase |
50 HP |
|
Horsepower Rating, 600 VAC, Time Delay, 3-Phase |
150 HP |
|
Horsepower Rating, 250 VDC |
40 HP |
|
CSA Compliance |
Yes |
|
UL Listed |
Yes |
|
cUL Listed |
Yes |
|
Height |
31.50 in |
|
Width |
13.30 in |
|
Weight |
33 lb |
Information About TH3364
The TH3364 is part of ABB's Heavy Duty Safety Switch family, formerly associated with GE Industrial Solutions, and is designed for demanding industrial power distribution applications. Its enclosed construction incorporates a mechanically operated disconnect mechanism, three switching poles, fuse provisions, and a protective NEMA 1 steel enclosure for indoor installations. The switch supports three-phase electrical systems up to 600 VAC and provides horsepower-rated switching capability for compatible motor loads. Designed to meet applicable UL, CSA, and NEMA requirements, it can be used as service equipment when installed in accordance with the National Electrical Code and applicable electrical regulations.
Key Features:
-
200 A Current Rating: Provides heavy-duty switching capacity for industrial and commercial electrical circuits.
-
600 VAC Voltage Rating: Supports electrical distribution and equipment disconnect applications up to 600 VAC.
-
Three-Pole Configuration: Allows simultaneous disconnection of three electrical phases.
-
Fusible Construction: Accommodates compatible fuses for overcurrent and short-circuit protection.
-
NEMA 1 Enclosure: Provides indoor protection against incidental contact with enclosed electrical components.
-
Quick-Make, Quick-Break Mechanism: Provides rapid contact operation during manual switching.
-
Cover Interlock System: Incorporates mechanical interlocking to restrict enclosure access during energized operation.
-
Service Equipment Suitability: Can serve as electrical service equipment when installed according to applicable code requirements.
-
Motor Load Ratings: Supports horsepower-rated switching for compatible three-phase and single-phase motor circuits.
-
Heavy-Duty Construction: Designed for commercial and industrial installations requiring frequent equipment isolation.
-
UL and CSA Compliance: Meets applicable requirements for enclosed and dead-front safety switches.
-
60/75°C Conductor Compatibility: Supports conductors with appropriate temperature ratings and installation requirements.
The TH3364 delivers the reliability and precision required for industrial electrical isolation, motor circuit disconnection, and protected power distribution applications.
Description
The ABB TH3364 is a heavy-duty fusible safety switch designed for electrical isolation, circuit protection, and equipment disconnect applications in commercial and industrial facilities. ABB part number TH3364 features a 200 A current rating, 600 VAC maximum operating voltage, and a three-pole switching configuration housed in a NEMA 1 indoor enclosure. Its quick-make, quick-break operating mechanism and cover interlock system support controlled switching and maintenance of three-phase electrical equipment.
Technical Specifications
|
Condition |
New/Never Used Surplus |
|
Brand |
ABB / GE Industrial Solutions |
|
Category |
Electrical Distribution & Power Control |
|
Part Number |
TH3364 |
|
Subcategory |
Heavy-Duty Fusible Safety Switches |
|
Product Type |
Heavy-Duty Safety Disconnect Switch |
|
Series |
Heavy Duty |
|
GO Schedule |
S1 |
|
Voltage Rating |
600 VAC |
|
Amperage Rating |
200 A |
|
Number of Poles |
3 |
|
Number of Wires |
3 |
|
Switch Type |
Fusible |
|
Enclosure Rating |
NEMA 1 (Indoor) |
|
Operating Mechanism |
Quick-Make, Quick-Break |
|
Wire Range (Cu/Al) |
2 × 250 |
|
Horsepower Rating, 480 VAC, NEC Standard, 1-Phase |
25 HP |
|
Horsepower Rating, 480 VAC, NEC Standard, 3-Phase |
50 HP |
|
Horsepower Rating, 480 VAC, Time Delay, 1-Phase |
50 HP |
|
Horsepower Rating, 480 VAC, Time Delay, 3-Phase |
125 HP |
|
Horsepower Rating, 600 VAC, NEC Standard, 1-Phase |
30 HP |
|
Horsepower Rating, 600 VAC, NEC Standard, 3-Phase |
60 HP |
|
Horsepower Rating, 600 VAC, Time Delay, 1-Phase |
50 HP |
|
Horsepower Rating, 600 VAC, Time Delay, 3-Phase |
150 HP |
|
Horsepower Rating, 250 VDC |
40 HP |
|
CSA Compliance |
Yes |
|
UL Listed |
Yes |
|
cUL Listed |
Yes |
|
Height |
31.50 in |
|
Width |
13.30 in |
|
Weight |
33 lb |
Information About TH3364
The TH3364 is part of ABB's Heavy Duty Safety Switch family, formerly associated with GE Industrial Solutions, and is designed for demanding industrial power distribution applications. Its enclosed construction incorporates a mechanically operated disconnect mechanism, three switching poles, fuse provisions, and a protective NEMA 1 steel enclosure for indoor installations. The switch supports three-phase electrical systems up to 600 VAC and provides horsepower-rated switching capability for compatible motor loads. Designed to meet applicable UL, CSA, and NEMA requirements, it can be used as service equipment when installed in accordance with the National Electrical Code and applicable electrical regulations.
Key Features:
-
200 A Current Rating: Provides heavy-duty switching capacity for industrial and commercial electrical circuits.
-
600 VAC Voltage Rating: Supports electrical distribution and equipment disconnect applications up to 600 VAC.
-
Three-Pole Configuration: Allows simultaneous disconnection of three electrical phases.
-
Fusible Construction: Accommodates compatible fuses for overcurrent and short-circuit protection.
-
NEMA 1 Enclosure: Provides indoor protection against incidental contact with enclosed electrical components.
-
Quick-Make, Quick-Break Mechanism: Provides rapid contact operation during manual switching.
-
Cover Interlock System: Incorporates mechanical interlocking to restrict enclosure access during energized operation.
-
Service Equipment Suitability: Can serve as electrical service equipment when installed according to applicable code requirements.
-
Motor Load Ratings: Supports horsepower-rated switching for compatible three-phase and single-phase motor circuits.
-
Heavy-Duty Construction: Designed for commercial and industrial installations requiring frequent equipment isolation.
-
UL and CSA Compliance: Meets applicable requirements for enclosed and dead-front safety switches.
-
60/75°C Conductor Compatibility: Supports conductors with appropriate temperature ratings and installation requirements.
The TH3364 delivers the reliability and precision required for industrial electrical isolation, motor circuit disconnection, and protected power distribution applications.