ABB XT1NU3060AYD000XXX 60 Ampere Three-Pole SACE Tmax XT1 Molded Case Circuit Breaker
- Regular price
- $567.00
- Sale price
- $567.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: XT1NU3060AYD000XXX
Description
The ABB XT1NU3060AYD000XXX is a SACE Tmax XT1 molded case circuit breaker designed for feeder and branch-circuit protection in low-voltage power distribution systems. Rated at 60 amperes with three poles, it uses fixed thermal-magnetic protection and provides a 25 kiloampere interrupting rating at 480 volts alternating current for compatible ReliaGear neXT panelboard applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | ABB |
| Category | Circuit Breaker |
| Part Number | XT1NU3060AYD000XXX |
| Subcategory | Molded Case Circuit Breaker |
| Product Family | SACE Tmax XT |
| Frame | XT1, 125-ampere frame |
| Rated Current | 60 amperes |
| Number of Poles | 3 |
| Trip Unit | Fixed Thermal-Magnetic |
| Trip Functions | Long-Time and Instantaneous |
| Interrupting Rating at 480 Volts | 25 kiloamperes |
| Interrupting Rating at 240 Volts | 50 kiloamperes |
| Interrupting Rating at 600Y/347 Volts | 18 kiloamperes |
| Continuous Current Rating | 80 percent |
| Panelboard Compatibility | ReliaGear neXT |
| Load-Side Conductor Range | 10 American Wire Gauge through 2/0 American Wire Gauge, copper or aluminum |
| Weight | 5.19 lbs |
Information About XT1NU3060AYD000XXX
The XT1NU3060AYD000XXX is an ABB SACE Tmax XT1 circuit breaker built on the 125-ampere XT1 frame and configured for 60-ampere operation. Its fixed thermal-magnetic trip unit provides long-time overload and instantaneous short-circuit protection without requiring electronic trip-unit programming. The breaker is configured for ReliaGear neXT panelboard installation and provides load-side terminals accepting one copper or aluminum conductor from 10 American Wire Gauge through 2/0 American Wire Gauge. The assembly is listed for North American applications and combines three-pole switching, an 80-percent continuous-current rating, and multiple alternating-current and direct-current interrupting ratings.
Key Features:
- 60-Ampere Rating: Provides a fixed 60-ampere current rating for branch and feeder circuit protection in compatible power distribution equipment.
- Three-Pole Configuration: Uses three poles for simultaneous protection and switching of three-phase electrical circuits.
- Thermal-Magnetic Protection: The fixed thermal-magnetic trip unit provides long-time overload and instantaneous short-circuit protection.
- 25-Kiloampere Interrupting Rating: ABB rates the N-performance XT1 configuration at 25 kiloamperes at 480 volts alternating current.
- XT1 125-Ampere Frame: Built on ABB's compact SACE Tmax XT1 frame with a maximum frame rating of 125 amperes.
- ReliaGear neXT Compatibility: This exact ordering code is listed by ABB for use as a main or branch feeder breaker in compatible ReliaGear neXT power panelboards.
- Copper and Aluminum Conductors: Load-side terminals accommodate one 10 American Wire Gauge through 2/0 American Wire Gauge conductor per pole.
- North American Certification: The exact product configuration is supplied as an Underwriters Laboratories and Canadian Standards Association version for North American electrical installations.
The XT1NU3060AYD000XXX delivers the reliability and precision required for overload and short-circuit protection in commercial and industrial low-voltage power distribution systems.
Description
The ABB XT1NU3060AYD000XXX is a SACE Tmax XT1 molded case circuit breaker designed for feeder and branch-circuit protection in low-voltage power distribution systems. Rated at 60 amperes with three poles, it uses fixed thermal-magnetic protection and provides a 25 kiloampere interrupting rating at 480 volts alternating current for compatible ReliaGear neXT panelboard applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | ABB |
| Category | Circuit Breaker |
| Part Number | XT1NU3060AYD000XXX |
| Subcategory | Molded Case Circuit Breaker |
| Product Family | SACE Tmax XT |
| Frame | XT1, 125-ampere frame |
| Rated Current | 60 amperes |
| Number of Poles | 3 |
| Trip Unit | Fixed Thermal-Magnetic |
| Trip Functions | Long-Time and Instantaneous |
| Interrupting Rating at 480 Volts | 25 kiloamperes |
| Interrupting Rating at 240 Volts | 50 kiloamperes |
| Interrupting Rating at 600Y/347 Volts | 18 kiloamperes |
| Continuous Current Rating | 80 percent |
| Panelboard Compatibility | ReliaGear neXT |
| Load-Side Conductor Range | 10 American Wire Gauge through 2/0 American Wire Gauge, copper or aluminum |
| Weight | 5.19 lbs |
Information About XT1NU3060AYD000XXX
The XT1NU3060AYD000XXX is an ABB SACE Tmax XT1 circuit breaker built on the 125-ampere XT1 frame and configured for 60-ampere operation. Its fixed thermal-magnetic trip unit provides long-time overload and instantaneous short-circuit protection without requiring electronic trip-unit programming. The breaker is configured for ReliaGear neXT panelboard installation and provides load-side terminals accepting one copper or aluminum conductor from 10 American Wire Gauge through 2/0 American Wire Gauge. The assembly is listed for North American applications and combines three-pole switching, an 80-percent continuous-current rating, and multiple alternating-current and direct-current interrupting ratings.
Key Features:
- 60-Ampere Rating: Provides a fixed 60-ampere current rating for branch and feeder circuit protection in compatible power distribution equipment.
- Three-Pole Configuration: Uses three poles for simultaneous protection and switching of three-phase electrical circuits.
- Thermal-Magnetic Protection: The fixed thermal-magnetic trip unit provides long-time overload and instantaneous short-circuit protection.
- 25-Kiloampere Interrupting Rating: ABB rates the N-performance XT1 configuration at 25 kiloamperes at 480 volts alternating current.
- XT1 125-Ampere Frame: Built on ABB's compact SACE Tmax XT1 frame with a maximum frame rating of 125 amperes.
- ReliaGear neXT Compatibility: This exact ordering code is listed by ABB for use as a main or branch feeder breaker in compatible ReliaGear neXT power panelboards.
- Copper and Aluminum Conductors: Load-side terminals accommodate one 10 American Wire Gauge through 2/0 American Wire Gauge conductor per pole.
- North American Certification: The exact product configuration is supplied as an Underwriters Laboratories and Canadian Standards Association version for North American electrical installations.
The XT1NU3060AYD000XXX delivers the reliability and precision required for overload and short-circuit protection in commercial and industrial low-voltage power distribution systems.