Part #: AFC-1000 Manufactured by: Potter
Regular price
$2,130.00
Sale price
$2,130.00
Regular price
2 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The AFC-1000 is a Potter 1,270-point addressable fire alarm control panel offering robust output capacity and integrated c...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: AFC-1000
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Potter
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: AFC-1000

Description / Specifications

Description 

The Potter AFC-1000 is an expandable analog addressable fire alarm control panel supporting up to 1,270 points. It features a 10-amp power supply, six regulated NACs, four programmable I/O circuits, built-in IP communication, and extensive event logging for large-scale fire protection systems.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Potter
Category Fire Alarm Systems
Part Number AFC-1000
Subcategory Addressable Fire Alarm Control Panel
System Capacity 1,270 addresses (expandable with multi-point SLC modules)
Zones 1,500 software zones
Event History 4,000 events
Power Supply 10 A, expandable to 315 A
Notification Appliance Circuits (NACs) 6 outputs, 3 A each, expandable to 192
Input/Output Circuits 4 outputs, 1 A each
Synchronization System Sensor, Gentex, Cooper/Wheelock, AMSECO; Quadrasync supported
Smoke Sensitivity Test NFPA 72 Compliant, built-in
Communication Built-in IP communicator, optional two-line DACT (UD-2000)
Network Interface Ethernet port for programming and monitoring
Email Reporting System status, reports, and event notifications
Dedicated Relays Alarm, Supervisory, and Trouble
AC Input 120 VAC, 5.0 A or 240 VAC, 3.0 A, 50/60 Hz
Battery Charger 8–55 Ah, 27.3 VDC output
Standby Current 130 mA
Alarm Current 220 mA
P-Link Current 1 A max
Enclosure 16-gauge cold rolled steel with locked door and Lexan viewing window
Dimensions 18 15/16 in W x 27 5/16 in H x 4 7/16 in D
Temperature Range 32° to 120°F (0° to 49°C), 93% max humidity (non-condensing)
Standards NFPA 13, 15, 16, 17, 17A, 70, 72, 750; ANSI/UL 864; IBC
Weight 16 lbs

 

 

Information About AFC-1000

The AFC-1000 is a Potter analog addressable fire alarm control panel built for high-capacity installations, with support for up to 1,270 devices on a single system. It offers six NAC outputs and four programmable I/O circuits, all regulated and configurable for steady signal, synchronization, constant power, releasing, or door holder power. The system incorporates Quadrasync technology, allowing multiple strobe brands to flash in sync across different outputs. With built-in IP communication, Ethernet connectivity, and optional DACT, the AFC-1000 delivers extensive networking and reporting functions, while its 4,000-event buffer and NFPA 72 smoke sensitivity test support compliance and detailed monitoring.

Key Features:

  • Large System Capacity: Supports 1,270 addressable devices with expansion through multi-point SLC modules.
  • High Output Power: Includes a 10 A regulated power supply expandable up to 315 A for large installations.
  • Multiple NACs and I/Os: Provides six NACs rated at 3 A each and four I/O circuits rated at 1 A each, fully programmable.
  • Quadrasync Strobe Control: Synchronizes strobes from Gentex, System Sensor, AMSECO, and Wheelock simultaneously across outputs.
  • Event Tracking: 4,000-event history buffer ensures comprehensive system monitoring and troubleshooting.
  • Built-in Communication: Features integrated IP communicator and Ethernet connectivity with optional two-line DACT.
  • Flexible Programming: 1,500 software zones for detailed system configuration and management.
  • Compliance Ready: Meets NFPA 72 standards with built-in smoke sensitivity testing.
  • Rugged Construction: Housed in a steel enclosure with locked Lexan window for durability and security.
  • Environmental Resilience: Operates from 32° to 120°F with up to 93% humidity non-condensing.

The AFC-1000 delivers the reliability and precision required for managing large and complex fire alarm systems in commercial, institutional, and industrial facilities.

IQElectro is not an authorized distributor.
QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Potter AFC-1000 is an expandable analog addressable fire alarm control panel supporting up to 1,270 points. It features a 10-amp power supply, six regulated NACs, four programmable I/O circuits, built-in IP communication, and extensive event logging for large-scale fire protection systems.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Potter
Category Fire Alarm Systems
Part Number AFC-1000
Subcategory Addressable Fire Alarm Control Panel
System Capacity 1,270 addresses (expandable with multi-point SLC modules)
Zones 1,500 software zones
Event History 4,000 events
Power Supply 10 A, expandable to 315 A
Notification Appliance Circuits (NACs) 6 outputs, 3 A each, expandable to 192
Input/Output Circuits 4 outputs, 1 A each
Synchronization System Sensor, Gentex, Cooper/Wheelock, AMSECO; Quadrasync supported
Smoke Sensitivity Test NFPA 72 Compliant, built-in
Communication Built-in IP communicator, optional two-line DACT (UD-2000)
Network Interface Ethernet port for programming and monitoring
Email Reporting System status, reports, and event notifications
Dedicated Relays Alarm, Supervisory, and Trouble
AC Input 120 VAC, 5.0 A or 240 VAC, 3.0 A, 50/60 Hz
Battery Charger 8–55 Ah, 27.3 VDC output
Standby Current 130 mA
Alarm Current 220 mA
P-Link Current 1 A max
Enclosure 16-gauge cold rolled steel with locked door and Lexan viewing window
Dimensions 18 15/16 in W x 27 5/16 in H x 4 7/16 in D
Temperature Range 32° to 120°F (0° to 49°C), 93% max humidity (non-condensing)
Standards NFPA 13, 15, 16, 17, 17A, 70, 72, 750; ANSI/UL 864; IBC
Weight 16 lbs

 

 

Information About AFC-1000

The AFC-1000 is a Potter analog addressable fire alarm control panel built for high-capacity installations, with support for up to 1,270 devices on a single system. It offers six NAC outputs and four programmable I/O circuits, all regulated and configurable for steady signal, synchronization, constant power, releasing, or door holder power. The system incorporates Quadrasync technology, allowing multiple strobe brands to flash in sync across different outputs. With built-in IP communication, Ethernet connectivity, and optional DACT, the AFC-1000 delivers extensive networking and reporting functions, while its 4,000-event buffer and NFPA 72 smoke sensitivity test support compliance and detailed monitoring.

Key Features:

  • Large System Capacity: Supports 1,270 addressable devices with expansion through multi-point SLC modules.
  • High Output Power: Includes a 10 A regulated power supply expandable up to 315 A for large installations.
  • Multiple NACs and I/Os: Provides six NACs rated at 3 A each and four I/O circuits rated at 1 A each, fully programmable.
  • Quadrasync Strobe Control: Synchronizes strobes from Gentex, System Sensor, AMSECO, and Wheelock simultaneously across outputs.
  • Event Tracking: 4,000-event history buffer ensures comprehensive system monitoring and troubleshooting.
  • Built-in Communication: Features integrated IP communicator and Ethernet connectivity with optional two-line DACT.
  • Flexible Programming: 1,500 software zones for detailed system configuration and management.
  • Compliance Ready: Meets NFPA 72 standards with built-in smoke sensitivity testing.
  • Rugged Construction: Housed in a steel enclosure with locked Lexan window for durability and security.
  • Environmental Resilience: Operates from 32° to 120°F with up to 93% humidity non-condensing.

The AFC-1000 delivers the reliability and precision required for managing large and complex fire alarm systems in commercial, institutional, and industrial facilities.