AFC-50 | Potter Addressable Fire Alarm Control Panel, 50 Points, IP Communicator, 5A Power
AFC-50 | Potter Addressable Fire Alarm Control Panel, 50 Points, IP Communicator, 5A Power
AFC-50 | Potter Addressable Fire Alarm Control Panel, 50 Points, IP Communicator, 5A Power
    AFC-50 | Potter Addressable Fire Alarm Control Panel, 50 Points, IP Communicator, 5A Power
AFC-50 | Potter Addressable Fire Alarm Control Panel, 50 Points, IP Communicator, 5A Power

AFC-50 | Potter Addressable Fire Alarm Control Panel, 50 Points, IP Communicator, 5A Power

Part #: AFC-50 Manufactured by: Potter
Regular price
$1,206.00
Sale price
$1,206.00
Regular price
$0.00
2 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The AFC-50 is an addressable fire alarm control panel designed to provide powerful detection and communication features in...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: AFC-50
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Potter
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: AFC-50

Description / Specifications

Description 

The Potter AFC-50 is an intelligent analog addressable fire alarm control panel supporting up to 50 devices. Designed for small to medium-sized facilities, it provides reliable detection, communication, and control through flexible SLC configurations. With built-in networking, power expansion, and strobe synchronization, the AFC-50 ensures scalable fire protection with comprehensive system integration.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Potter
Category Fire Alarm Equipment
Part Number AFC-50
Subcategory Control Panels
Type Analog Addressable Fire Alarm Control Panel
Device Capacity 50 addressable points (expandable with multi-point SLC modules)
Zones 99 software zones
Display LCD user interface with menu navigation
Relays Dedicated Alarm, Supervisory, and Trouble relays
Power Supply 5 Amps standard, expandable up to 310 Amps with PSN-1000
NAC Circuits Two Class A/B NACs, 3 Amps each, expandable up to 188
I/O Circuits Two Class A/B I/O circuits, 1 Amp each
Strobe Sync Gentex, AMSECO, System Sensor, Cooper Wheelock with Quadrasync
Communication Built-in IP communicator; optional two-line DACT
Programming Ethernet port for programming and network connectivity
Event History 4,000-event history buffer
Battery Charger 8–55 Ah, 27.3 VDC output
Operating Range 32° to 120°F (0° to 49°C), up to 93% non-condensing humidity
Enclosure 16-gauge cold rolled steel with locking door and Lexan window
Approvals NFPA, UL 864, IBC, CS, RS, PPU, AUX, DAC, March, NC, Rev Pol, OT
Dimensions 16” W × 17” H × 3” D
Weight 16 lbs

 

 

Information About AFC-50

The AFC-50 is part of Potter’s line of analog addressable fire alarm systems, offering modular expansion and advanced communication features. It operates with the exclusive Potter protocol, supporting a full range of sensors, heat detectors, and modules on a single SLC. Equipped with a 5-amp power supply, multiple NACs, and I/O circuits, the AFC-50 is engineered to meet NFPA and UL standards for dependable life safety. Its built-in IP communicator, Ethernet programming port, and optional DACT provide flexible connectivity options, making it suitable for diverse building applications.

Key Features:

  • Device Capacity: Supports up to 50 addressable points with expansion via SLC modules.
  • Power Supply: 5-amp capacity with two regulated 3-amp NACs and two 1-amp I/O circuits.
  • Strobe Synchronization: System-wide Quadrasync technology for Gentex, AMSECO, System Sensor, and Cooper Wheelock devices.
  • Expandable Power: Compatible with up to 31 PSN-1000 intelligent power supplies, adding up to 310 amps.
  • Built-in Communication: Integrated IP communicator with optional DACT for zone or point reporting.
  • Programming and Control: Ethernet port for configuration, email status reporting, and event notifications.
  • History Storage: 4,000-event history buffer for long-term system tracking.
  • Compliance: Meets NFPA 72, ANSI/UL 864, and IBC code requirements.

The AFC-50 delivers the reliability and precision required for intelligent addressable fire detection and facility protection.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Potter AFC-50 is an intelligent analog addressable fire alarm control panel supporting up to 50 devices. Designed for small to medium-sized facilities, it provides reliable detection, communication, and control through flexible SLC configurations. With built-in networking, power expansion, and strobe synchronization, the AFC-50 ensures scalable fire protection with comprehensive system integration.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Potter
Category Fire Alarm Equipment
Part Number AFC-50
Subcategory Control Panels
Type Analog Addressable Fire Alarm Control Panel
Device Capacity 50 addressable points (expandable with multi-point SLC modules)
Zones 99 software zones
Display LCD user interface with menu navigation
Relays Dedicated Alarm, Supervisory, and Trouble relays
Power Supply 5 Amps standard, expandable up to 310 Amps with PSN-1000
NAC Circuits Two Class A/B NACs, 3 Amps each, expandable up to 188
I/O Circuits Two Class A/B I/O circuits, 1 Amp each
Strobe Sync Gentex, AMSECO, System Sensor, Cooper Wheelock with Quadrasync
Communication Built-in IP communicator; optional two-line DACT
Programming Ethernet port for programming and network connectivity
Event History 4,000-event history buffer
Battery Charger 8–55 Ah, 27.3 VDC output
Operating Range 32° to 120°F (0° to 49°C), up to 93% non-condensing humidity
Enclosure 16-gauge cold rolled steel with locking door and Lexan window
Approvals NFPA, UL 864, IBC, CS, RS, PPU, AUX, DAC, March, NC, Rev Pol, OT
Dimensions 16” W × 17” H × 3” D
Weight 16 lbs

 

 

Information About AFC-50

The AFC-50 is part of Potter’s line of analog addressable fire alarm systems, offering modular expansion and advanced communication features. It operates with the exclusive Potter protocol, supporting a full range of sensors, heat detectors, and modules on a single SLC. Equipped with a 5-amp power supply, multiple NACs, and I/O circuits, the AFC-50 is engineered to meet NFPA and UL standards for dependable life safety. Its built-in IP communicator, Ethernet programming port, and optional DACT provide flexible connectivity options, making it suitable for diverse building applications.

Key Features:

  • Device Capacity: Supports up to 50 addressable points with expansion via SLC modules.
  • Power Supply: 5-amp capacity with two regulated 3-amp NACs and two 1-amp I/O circuits.
  • Strobe Synchronization: System-wide Quadrasync technology for Gentex, AMSECO, System Sensor, and Cooper Wheelock devices.
  • Expandable Power: Compatible with up to 31 PSN-1000 intelligent power supplies, adding up to 310 amps.
  • Built-in Communication: Integrated IP communicator with optional DACT for zone or point reporting.
  • Programming and Control: Ethernet port for configuration, email status reporting, and event notifications.
  • History Storage: 4,000-event history buffer for long-term system tracking.
  • Compliance: Meets NFPA 72, ANSI/UL 864, and IBC code requirements.