Part #: AMM-2F Manufactured by: Gamewell-FCI
Regular price
$101.00
Sale price
$101.00
Regular price
32 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The Gamewell Fci AMM-2F single Style B, Class B initiating device circuit (IDC) with a 47KW end-of-line resistor.
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: AMM-2F
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Gamewell-FCI
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: AMM-2F

Description / Specifications

Description 

The Gamewell-FCI AMM-2F is a compact mini monitor module designed to provide reliable input monitoring for addressable fire alarm systems. This module connects initiating devices to the system’s SLC loop, enabling accurate reporting and event signaling. The AMM-2F ensures dependable supervision for a wide range of fire detection inputs in indoor applications.

 


Technical Specifications 

Condition New/Never Used Surplus
Brand Gamewell-FCI
Category Fire Safety
Part Number AMM-2F
Subcategory Fire Alarm Control
Type Mini Monitor Module
Application Monitoring initiating device circuits
Use Environment Indoor use only
Operating Voltage Up to 32 VDC
Maximum IDC Line Resistance 40 ohms
IDC Type Style B / Class B
End-of-Line Resistor 47 kΩ
Compatibility Gamewell-FCI addressable control panels
Mounting Fits manual stations or standard device boxes
Functionality Supports manual stations, detectors, switches, and system inputs
Supervision Fully supervised initiating device circuit

 


Information About AMM-2F

The AMM-2F is part of the Gamewell-FCI addressable device family, engineered to deliver essential monitoring capabilities for initiating device circuits. Its compact construction allows installation within manual stations or standard device backboxes, offering flexibility across system layouts. Designed for seamless integration with Gamewell-FCI addressable control panels, it supports identification and configuration of various input types. The AMM-2F is typically used to monitor contacts, detectors, and system switches while incorporating technologies that maintain supervision and stable communication.

Key Features:

  • Miniature module design: Fits inside manual stations or device junction boxes for flexible placement.
  • Addressable circuit monitoring: Assigns an address to connected devices for clear identification on the SLC loop.
  • Supports multiple input types: Can be configured for detectors, switches, waterflow devices, or system controls.
  • Class B IDC support: Provides supervision of a Style B initiating device circuit.
  • 40-ohm line capability: Allows use with linear heat detection and longer wire runs.
  • Indoor-rated construction: Suitable for indoor fire alarm applications.
  • Wide device compatibility: Designed for Gamewell-FCI addressable system families.
  • Compact form factor: Simplifies installation in tight or concealed locations.

The AMM-2F delivers the reliability and precision required for accurate monitoring within addressable fire alarm systems.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Gamewell-FCI AMM-2F is a compact mini monitor module designed to provide reliable input monitoring for addressable fire alarm systems. This module connects initiating devices to the system’s SLC loop, enabling accurate reporting and event signaling. The AMM-2F ensures dependable supervision for a wide range of fire detection inputs in indoor applications.

 


Technical Specifications 

Condition New/Never Used Surplus
Brand Gamewell-FCI
Category Fire Safety
Part Number AMM-2F
Subcategory Fire Alarm Control
Type Mini Monitor Module
Application Monitoring initiating device circuits
Use Environment Indoor use only
Operating Voltage Up to 32 VDC
Maximum IDC Line Resistance 40 ohms
IDC Type Style B / Class B
End-of-Line Resistor 47 kΩ
Compatibility Gamewell-FCI addressable control panels
Mounting Fits manual stations or standard device boxes
Functionality Supports manual stations, detectors, switches, and system inputs
Supervision Fully supervised initiating device circuit

 


Information About AMM-2F

The AMM-2F is part of the Gamewell-FCI addressable device family, engineered to deliver essential monitoring capabilities for initiating device circuits. Its compact construction allows installation within manual stations or standard device backboxes, offering flexibility across system layouts. Designed for seamless integration with Gamewell-FCI addressable control panels, it supports identification and configuration of various input types. The AMM-2F is typically used to monitor contacts, detectors, and system switches while incorporating technologies that maintain supervision and stable communication.

Key Features:

  • Miniature module design: Fits inside manual stations or device junction boxes for flexible placement.
  • Addressable circuit monitoring: Assigns an address to connected devices for clear identification on the SLC loop.
  • Supports multiple input types: Can be configured for detectors, switches, waterflow devices, or system controls.
  • Class B IDC support: Provides supervision of a Style B initiating device circuit.
  • 40-ohm line capability: Allows use with linear heat detection and longer wire runs.
  • Indoor-rated construction: Suitable for indoor fire alarm applications.
  • Wide device compatibility: Designed for Gamewell-FCI addressable system families.
  • Compact form factor: Simplifies installation in tight or concealed locations.

The AMM-2F delivers the reliability and precision required for accurate monitoring within addressable fire alarm systems.