B10.2 - Thermal Unit, Type S, Type B, Melting Alloy, Class 20
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: B10.2
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Schneider Electric
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: B10.2

Description / Specifications

Description 

The Schneider Electric B10.2 is a thermal overload heater unit engineered to provide accurate motor protection within defined full-load amperage ranges. This component supports dependable operation in motor control systems by responding precisely to overcurrent conditions and preventing equipment damage.


 

Technical Specifications 

Condition New/Never Used Surplus
Brand Schneider Electric
Category Contactors & Starters
Part Number B10.2
Subcategory Thermal Overload/Heater
Family B Series
Type B
Sensing Method Melting Alloy
Compatible Starters Square D NEMA 00, 0, 1, 1P, 2
Full Load Amps (Min) 6.4 A
Full Load Amps (Max) 7.53 A
Mounting Type Plug-On
Application Thermal overload protection for motor starters
Construction Standard thermal heating element
Operating Use Case Industrial motor control and protection



Information About B10.2

The B10.2 is a thermal overload heater unit designed for use with Square D NEMA motor starters in sizes 00, 0, 1, 1P, and 2. It is part of the Schneider Electric B Series, constructed to deliver stable sensing performance using a melting-alloy mechanism for accurate thermal response. The design integrates seamlessly with compatible NEMA starters, allowing reliable installation through a plug-on mounting configuration. This unit is typically applied in industrial motor control panels where precise overload protection and consistent thermal tracking are required.

Key Features

  • Melting-alloy sensing method: Provides precise thermal response under overload conditions.
  • B Series design: Ensures consistent performance across compatible Schneider Electric starter systems.
  • Defined FLA range: Supports motors operating between 6.4A and 7.53A for proper overload coordination.
  • Plug-on mounting: Allows quick, secure installation into Square D NEMA starter assemblies.
  • Compact thermal unit: Fits efficiently within standard motor control configurations.
  • Engineered compatibility: Designed for Square D NEMA sizes 00, 0, 1, 1P, and 2.
  • Durable construction: Offers long-term stability in industrial motor protection environments.
  • Reliable thermal protection: Prevents overheating-related damage in motor applications.

The B10.2 delivers the reliability and precision required for protecting motors in demanding industrial control systems.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Schneider Electric B10.2 is a thermal overload heater unit engineered to provide accurate motor protection within defined full-load amperage ranges. This component supports dependable operation in motor control systems by responding precisely to overcurrent conditions and preventing equipment damage.


 

Technical Specifications 

Condition New/Never Used Surplus
Brand Schneider Electric
Category Contactors & Starters
Part Number B10.2
Subcategory Thermal Overload/Heater
Family B Series
Type B
Sensing Method Melting Alloy
Compatible Starters Square D NEMA 00, 0, 1, 1P, 2
Full Load Amps (Min) 6.4 A
Full Load Amps (Max) 7.53 A
Mounting Type Plug-On
Application Thermal overload protection for motor starters
Construction Standard thermal heating element
Operating Use Case Industrial motor control and protection



Information About B10.2

The B10.2 is a thermal overload heater unit designed for use with Square D NEMA motor starters in sizes 00, 0, 1, 1P, and 2. It is part of the Schneider Electric B Series, constructed to deliver stable sensing performance using a melting-alloy mechanism for accurate thermal response. The design integrates seamlessly with compatible NEMA starters, allowing reliable installation through a plug-on mounting configuration. This unit is typically applied in industrial motor control panels where precise overload protection and consistent thermal tracking are required.

Key Features

  • Melting-alloy sensing method: Provides precise thermal response under overload conditions.
  • B Series design: Ensures consistent performance across compatible Schneider Electric starter systems.
  • Defined FLA range: Supports motors operating between 6.4A and 7.53A for proper overload coordination.
  • Plug-on mounting: Allows quick, secure installation into Square D NEMA starter assemblies.
  • Compact thermal unit: Fits efficiently within standard motor control configurations.
  • Engineered compatibility: Designed for Square D NEMA sizes 00, 0, 1, 1P, and 2.
  • Durable construction: Offers long-term stability in industrial motor protection environments.
  • Reliable thermal protection: Prevents overheating-related damage in motor applications.

The B10.2 delivers the reliability and precision required for protecting motors in demanding industrial control systems.