BK9105 | Beckhoff | IP Bus Coupler
BK9105 | Beckhoff | IP Bus Coupler
BK9105 | Beckhoff | IP Bus Coupler
    BK9105 | Beckhoff | IP Bus Coupler
BK9105 | Beckhoff | IP Bus Coupler

BK9105 | Beckhoff | IP Bus Coupler

Part #: BK9105 Manufactured by: Beckhoff
Regular price
$794.00
Sale price
$794.00
Regular price
4 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The BK9105 Bus Coupler serves as a bridge between EtherNet/IP and modular electronic terminal blocks, facilitating seamles...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: BK9105
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Beckhoff
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: BK9105

Description / Specifications

Description

The BK9105 Bus Coupler facilitates the connection of EtherNet/IP with modular, extendable electronic terminal blocks. Each unit comprises one Bus Coupler, accommodating any number from 1 to 64 terminals (255 with K-bus extension), and one end terminal.

Automatically recognizing connected terminals, the Bus Coupler assigns inputs and outputs to process image words. It supports 10 Mbit/s and 100 Mbit/s Ethernet via standard RJ45 connectors. IP address configuration is done through the DIP switch, offset to a user-defined start address. In DHCP networks, the Bus Coupler obtains its IP address from the DHCP server.

Technical Specifications

 

 

Part #

BK9105

Manufacturer

BECKHOFF

Category

PLCs/Machine Control

Subcategory

PLC Module/Rack

Number of Bus Terminals

64 (255 with K-bus extension)

Max. number of bytes fieldbus

492 byte input and 492 byte output

Digital peripheral signals

3,936 inputs/outputs

Analog peripheral signals

122 inputs/outputs

Configuration possibility

via KS2000

Protocol

EtherNet/IP

Data transfer rates

10/100 Mbit/s, automatic recognition of the transmission rate

Bus interface

2 x RJ45 (2-channel switch)

Data transfer medium

4 x 2 twisted pair copper cable; category 3 (10 Mbit/s), category 5 (100 Mbit/s)

Power supply

24 V DC (-15 %/+20 %)

Input current

70 mA + (total K-bus current)/4, 500 mA max.

Starting current

2.5 x continuous current

Recommended fuse

≤ 10 A

Current supply K-bus

1750 mA

Power contacts

max. 24 V DC/max. 10 A

Electrical isolation

500 V (power contact/supply voltage/fieldbus)

Topology

line or star wiring

Cascading

up to 20 BK9105 or max. line length 2 km

Distance between stations

100 m between hub/switch and bus coupler or between bus coupler and bus coupler

Weight

approx. 170 g

Operating/storage temperature

-25…+60 °C/-40…+85 °C

Relative humidity

95 %, no condensation

Vibration/shock resistance

conforms to EN 60068-2-6/EN 60068-2-27

EMC immunity/emission

conforms to EN 61000-6-2/EN 61000-6-4

Protect. rating/installation pos.

IP20/variable

Approvals/markings

CE, UL, ATEX, IECEx, DNV GL

 

 

Information About BK9105

 

The BK9105 Bus Coupler integrates EtherNet/IP with modular, extendable electronic terminal blocks. A single unit comprises one Bus Coupler, accommodating from 1 to 64 terminals (255 with K-bus extension), along with one end terminal.

This Bus Coupler automatically recognizes the connected terminals and assigns inputs and outputs to the process image words. It supports Ethernet speeds of 10 Mbit/s and 100 Mbit/s, utilizing standard RJ45 connectors. IP address configuration is facilitated via the DIP switch, with an offset to a freely selectable start address. In DHCP-enabled networks, the Bus Coupler obtains its IP address from the DHCP server.

Featuring a 3-port switch, the BK9105 facilitates flexible connectivity. Two ports operate externally via RJ45 connectors, enabling configuration of I/O stations with a line topology, minimizing wiring and cabling costs. The maximum distance between two couplers is 100 m. Cascading up to 20 BK9105 Bus Couplers extends the line length to a maximum of 2 km.

Ethernet/IP, endorsed by ODVA (Open DeviceNet Vendor Association), serves as the Industrial Ethernet standard. It is grounded on Ethernet TCP/IP and UDP/IP, where IP denotes Industrial Protocol. Essentially, Ethernet/IP extends the Common Industrial Protocol (CIP), initially employed in ControlNet and DeviceNet, to Ethernet TCP/IP and UDP/IP environments.

 

 

Manufacturer information

Beckhoff Automation is a German manufacturer of open automation systems, including industrial PCs, I/O and fieldbus components, drive technology, automation software, and hardware for machine vision. Beckhoff is known for its innovative and reliable automation technology, which is used in a wide range of industries. The company is committed to providing customers with the best possible automation solutions to help them succeed in their businesse

IQElectro is not an authorized distributor.
QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description

The BK9105 Bus Coupler facilitates the connection of EtherNet/IP with modular, extendable electronic terminal blocks. Each unit comprises one Bus Coupler, accommodating any number from 1 to 64 terminals (255 with K-bus extension), and one end terminal.

Automatically recognizing connected terminals, the Bus Coupler assigns inputs and outputs to process image words. It supports 10 Mbit/s and 100 Mbit/s Ethernet via standard RJ45 connectors. IP address configuration is done through the DIP switch, offset to a user-defined start address. In DHCP networks, the Bus Coupler obtains its IP address from the DHCP server.

Technical Specifications

 

 

Part #

BK9105

Manufacturer

BECKHOFF

Category

PLCs/Machine Control

Subcategory

PLC Module/Rack

Number of Bus Terminals

64 (255 with K-bus extension)

Max. number of bytes fieldbus

492 byte input and 492 byte output

Digital peripheral signals

3,936 inputs/outputs

Analog peripheral signals

122 inputs/outputs

Configuration possibility

via KS2000

Protocol

EtherNet/IP

Data transfer rates

10/100 Mbit/s, automatic recognition of the transmission rate

Bus interface

2 x RJ45 (2-channel switch)

Data transfer medium

4 x 2 twisted pair copper cable; category 3 (10 Mbit/s), category 5 (100 Mbit/s)

Power supply

24 V DC (-15 %/+20 %)

Input current

70 mA + (total K-bus current)/4, 500 mA max.

Starting current

2.5 x continuous current

Recommended fuse

≤ 10 A

Current supply K-bus

1750 mA

Power contacts

max. 24 V DC/max. 10 A

Electrical isolation

500 V (power contact/supply voltage/fieldbus)

Topology

line or star wiring

Cascading

up to 20 BK9105 or max. line length 2 km

Distance between stations

100 m between hub/switch and bus coupler or between bus coupler and bus coupler

Weight

approx. 170 g

Operating/storage temperature

-25…+60 °C/-40…+85 °C

Relative humidity

95 %, no condensation

Vibration/shock resistance

conforms to EN 60068-2-6/EN 60068-2-27

EMC immunity/emission

conforms to EN 61000-6-2/EN 61000-6-4

Protect. rating/installation pos.

IP20/variable

Approvals/markings

CE, UL, ATEX, IECEx, DNV GL

 

 

Information About BK9105

 

The BK9105 Bus Coupler integrates EtherNet/IP with modular, extendable electronic terminal blocks. A single unit comprises one Bus Coupler, accommodating from 1 to 64 terminals (255 with K-bus extension), along with one end terminal.

This Bus Coupler automatically recognizes the connected terminals and assigns inputs and outputs to the process image words. It supports Ethernet speeds of 10 Mbit/s and 100 Mbit/s, utilizing standard RJ45 connectors. IP address configuration is facilitated via the DIP switch, with an offset to a freely selectable start address. In DHCP-enabled networks, the Bus Coupler obtains its IP address from the DHCP server.

Featuring a 3-port switch, the BK9105 facilitates flexible connectivity. Two ports operate externally via RJ45 connectors, enabling configuration of I/O stations with a line topology, minimizing wiring and cabling costs. The maximum distance between two couplers is 100 m. Cascading up to 20 BK9105 Bus Couplers extends the line length to a maximum of 2 km.

Ethernet/IP, endorsed by ODVA (Open DeviceNet Vendor Association), serves as the Industrial Ethernet standard. It is grounded on Ethernet TCP/IP and UDP/IP, where IP denotes Industrial Protocol. Essentially, Ethernet/IP extends the Common Industrial Protocol (CIP), initially employed in ControlNet and DeviceNet, to Ethernet TCP/IP and UDP/IP environments.

 

 

Manufacturer information

Beckhoff Automation is a German manufacturer of open automation systems, including industrial PCs, I/O and fieldbus components, drive technology, automation software, and hardware for machine vision. Beckhoff is known for its innovative and reliable automation technology, which is used in a wide range of industries. The company is committed to providing customers with the best possible automation solutions to help them succeed in their businesse