BK9105 | Beckhoff | IP Bus Coupler
BK9105 | Beckhoff | IP Bus Coupler
Part #: BK9105 Manufactured by: Beckhoff

BK9105 | Beckhoff | IP Bus Coupler

Regular price
$794.00
Sale price
$794.00
Regular price
Never Used Surplus
1 in Stock
Product Overview
The BK9105 Bus Coupler serves as a bridge between EtherNet/IP and modular electronic terminal blocks, facilitating seamles...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
Product comes with IQElectro 2-Year Warranty
Warranty for item #: BK9105
IQElectro International provides a 2-year warranty on every product we offer. Our complimentary 2-year warranty ensures that every IQElectro purchase is a trustworthy and reliable investment in the future of your company.
IQElectro is NOT an authorized distributor for Beckhoff
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.
BK9105 | Beckhoff | IP Bus Coupler
    BK9105 | Beckhoff | IP Bus Coupler
BK9105 | Beckhoff | IP Bus Coupler
Return/Exchange within 30-Days.
If any product is damaged upon delivery, you may request an Exchange or Refund within 30 days of receiving your order.
2-3-Day Free Shipping
"IQElectro provides free shipping within 2-3 days from the moment the order is placed on our website.

Product Description P/N: BK9105

Description / Specifications

Description

The BK9105 Bus Coupler facilitates the connection of EtherNet/IP with modular, extendable electronic terminal blocks. Each unit comprises one Bus Coupler, accommodating any number from 1 to 64 terminals (255 with K-bus extension), and one end terminal.

Automatically recognizing connected terminals, the Bus Coupler assigns inputs and outputs to process image words. It supports 10 Mbit/s and 100 Mbit/s Ethernet via standard RJ45 connectors. IP address configuration is done through the DIP switch, offset to a user-defined start address. In DHCP networks, the Bus Coupler obtains its IP address from the DHCP server.

Technical Specifications

 

 

Part #

BK9105

Manufacturer

BECKHOFF

Category

PLCs/Machine Control

Subcategory

PLC Module/Rack

Number of Bus Terminals

64 (255 with K-bus extension)

Max. number of bytes fieldbus

492 byte input and 492 byte output

Digital peripheral signals

3,936 inputs/outputs

Analog peripheral signals

122 inputs/outputs

Configuration possibility

via KS2000

Protocol

EtherNet/IP

Data transfer rates

10/100 Mbit/s, automatic recognition of the transmission rate

Bus interface

2 x RJ45 (2-channel switch)

Data transfer medium

4 x 2 twisted pair copper cable; category 3 (10 Mbit/s), category 5 (100 Mbit/s)

Power supply

24 V DC (-15 %/+20 %)

Input current

70 mA + (total K-bus current)/4, 500 mA max.

Starting current

2.5 x continuous current

Recommended fuse

≤ 10 A

Current supply K-bus

1750 mA

Power contacts

max. 24 V DC/max. 10 A

Electrical isolation

500 V (power contact/supply voltage/fieldbus)

Topology

line or star wiring

Cascading

up to 20 BK9105 or max. line length 2 km

Distance between stations

100 m between hub/switch and bus coupler or between bus coupler and bus coupler

Weight

approx. 170 g

Operating/storage temperature

-25…+60 °C/-40…+85 °C

Relative humidity

95 %, no condensation

Vibration/shock resistance

conforms to EN 60068-2-6/EN 60068-2-27

EMC immunity/emission

conforms to EN 61000-6-2/EN 61000-6-4

Protect. rating/installation pos.

IP20/variable

Approvals/markings

CE, UL, ATEX, IECEx, DNV GL

 

 

Information About BK9105

 

The BK9105 Bus Coupler integrates EtherNet/IP with modular, extendable electronic terminal blocks. A single unit comprises one Bus Coupler, accommodating from 1 to 64 terminals (255 with K-bus extension), along with one end terminal.

This Bus Coupler automatically recognizes the connected terminals and assigns inputs and outputs to the process image words. It supports Ethernet speeds of 10 Mbit/s and 100 Mbit/s, utilizing standard RJ45 connectors. IP address configuration is facilitated via the DIP switch, with an offset to a freely selectable start address. In DHCP-enabled networks, the Bus Coupler obtains its IP address from the DHCP server.

Featuring a 3-port switch, the BK9105 facilitates flexible connectivity. Two ports operate externally via RJ45 connectors, enabling configuration of I/O stations with a line topology, minimizing wiring and cabling costs. The maximum distance between two couplers is 100 m. Cascading up to 20 BK9105 Bus Couplers extends the line length to a maximum of 2 km.

Ethernet/IP, endorsed by ODVA (Open DeviceNet Vendor Association), serves as the Industrial Ethernet standard. It is grounded on Ethernet TCP/IP and UDP/IP, where IP denotes Industrial Protocol. Essentially, Ethernet/IP extends the Common Industrial Protocol (CIP), initially employed in ControlNet and DeviceNet, to Ethernet TCP/IP and UDP/IP environments.

 

 

Manufacturer information

Beckhoff Automation is a German manufacturer of open automation systems, including industrial PCs, I/O and fieldbus components, drive technology, automation software, and hardware for machine vision. Beckhoff is known for its innovative and reliable automation technology, which is used in a wide range of industries. The company is committed to providing customers with the best possible automation solutions to help them succeed in their businesse

Warrany image

IQElectro 2 Year Warranty

IQElectro offers a 2-Year Warranty on all our products. This complimentary two-year warranty ensures that every purchase from IQElectro is a secure investment in the future of your company.
Warranty Terms and Conditions
warningIQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses. Some hardware products may contain software and firmware and may not be legally operated without first obtaining an appropriate license from the manufacturer. IQElectro makes no representation as to whether a product will or will not have software or firmware and, if it does, whether the software or firmware is the revision level that you need for your application. IQElectro also makes no representations as to your ability or right to download or otherwise obtain software or firmware for the product from the Original Manufacturer, its distributors, or any other source. IQElectro also makes no representations as to your right to install any such software or firmware on the product. IQElectro will not obtain or supply software or firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing software or firmware. Customer acknowledges and agrees that IQElectro DOES NOT provide any software, firmware, operating system, or right-to-use licenses with the products it sells. Customers understand and agree that proper software (firmware) licensing, maintenance, and upgrades are subject to the applicable manufacturer's Licensing Agreement or similar document. Disclaimer Policy.
Description / Specifications

Description

The BK9105 Bus Coupler facilitates the connection of EtherNet/IP with modular, extendable electronic terminal blocks. Each unit comprises one Bus Coupler, accommodating any number from 1 to 64 terminals (255 with K-bus extension), and one end terminal.

Automatically recognizing connected terminals, the Bus Coupler assigns inputs and outputs to process image words. It supports 10 Mbit/s and 100 Mbit/s Ethernet via standard RJ45 connectors. IP address configuration is done through the DIP switch, offset to a user-defined start address. In DHCP networks, the Bus Coupler obtains its IP address from the DHCP server.

Technical Specifications

 

 

Part #

BK9105

Manufacturer

BECKHOFF

Category

PLCs/Machine Control

Subcategory

PLC Module/Rack

Number of Bus Terminals

64 (255 with K-bus extension)

Max. number of bytes fieldbus

492 byte input and 492 byte output

Digital peripheral signals

3,936 inputs/outputs

Analog peripheral signals

122 inputs/outputs

Configuration possibility

via KS2000

Protocol

EtherNet/IP

Data transfer rates

10/100 Mbit/s, automatic recognition of the transmission rate

Bus interface

2 x RJ45 (2-channel switch)

Data transfer medium

4 x 2 twisted pair copper cable; category 3 (10 Mbit/s), category 5 (100 Mbit/s)

Power supply

24 V DC (-15 %/+20 %)

Input current

70 mA + (total K-bus current)/4, 500 mA max.

Starting current

2.5 x continuous current

Recommended fuse

≤ 10 A

Current supply K-bus

1750 mA

Power contacts

max. 24 V DC/max. 10 A

Electrical isolation

500 V (power contact/supply voltage/fieldbus)

Topology

line or star wiring

Cascading

up to 20 BK9105 or max. line length 2 km

Distance between stations

100 m between hub/switch and bus coupler or between bus coupler and bus coupler

Weight

approx. 170 g

Operating/storage temperature

-25…+60 °C/-40…+85 °C

Relative humidity

95 %, no condensation

Vibration/shock resistance

conforms to EN 60068-2-6/EN 60068-2-27

EMC immunity/emission

conforms to EN 61000-6-2/EN 61000-6-4

Protect. rating/installation pos.

IP20/variable

Approvals/markings

CE, UL, ATEX, IECEx, DNV GL

 

 

Information About BK9105

 

The BK9105 Bus Coupler integrates EtherNet/IP with modular, extendable electronic terminal blocks. A single unit comprises one Bus Coupler, accommodating from 1 to 64 terminals (255 with K-bus extension), along with one end terminal.

This Bus Coupler automatically recognizes the connected terminals and assigns inputs and outputs to the process image words. It supports Ethernet speeds of 10 Mbit/s and 100 Mbit/s, utilizing standard RJ45 connectors. IP address configuration is facilitated via the DIP switch, with an offset to a freely selectable start address. In DHCP-enabled networks, the Bus Coupler obtains its IP address from the DHCP server.

Featuring a 3-port switch, the BK9105 facilitates flexible connectivity. Two ports operate externally via RJ45 connectors, enabling configuration of I/O stations with a line topology, minimizing wiring and cabling costs. The maximum distance between two couplers is 100 m. Cascading up to 20 BK9105 Bus Couplers extends the line length to a maximum of 2 km.

Ethernet/IP, endorsed by ODVA (Open DeviceNet Vendor Association), serves as the Industrial Ethernet standard. It is grounded on Ethernet TCP/IP and UDP/IP, where IP denotes Industrial Protocol. Essentially, Ethernet/IP extends the Common Industrial Protocol (CIP), initially employed in ControlNet and DeviceNet, to Ethernet TCP/IP and UDP/IP environments.

 

 

Manufacturer information

Beckhoff Automation is a German manufacturer of open automation systems, including industrial PCs, I/O and fieldbus components, drive technology, automation software, and hardware for machine vision. Beckhoff is known for its innovative and reliable automation technology, which is used in a wide range of industries. The company is committed to providing customers with the best possible automation solutions to help them succeed in their businesse

Check Out These Related Products

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)