Product Description P/N: AFS-951-1
Description
The Cleveland Controls AFS-951-1 is an adjustable differential air pressure sensing switch designed to monitor positive, negative, and differential air pressure in commercial and industrial ventilation systems. It features a field-adjustable setpoint range of 0.05 to 12.0 inches water column (in. w.c.) and a single-pole double-throw (SPDT) switch contact. Its NEMA 4-rated enclosure provides protection against dust, dirt, oil, and water.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Cleveland Controls |
| Manufacturer | UniControl Inc. |
| Category | HVAC & Building Automation |
| Part Number | AFS-951-1 |
| Subcategory | Differential Air Pressure Switches |
| Series | AFS-951 |
| Device Type | Adjustable Differential Air Pressure Switch |
| Setpoint Range | 0.05–12.0 in. w.c. |
| Switch Contact | SPDT, Normally Closed |
| Switch Differential | 0.02–0.8 in. w.c. Approx. |
| Maximum Pressure | 0.5 PSI |
| Electrical Rating | 15 A Non-Inductive at 277 VAC |
| Pilot Duty Rating | 300 VA at 277 VAC |
| Pressure Connections | Two 1/4-Inch NPT Female Fittings |
| Electrical Connection | Numbered Terminal Block |
| Conduit Opening | 7/8-Inch Opening for 1/2-Inch Conduit |
| Enclosure Material | 14-Gauge Enameled Steel |
| Protection Rating | NEMA 4 |
| Operating Temperature | -40°F to 180°F (-40°C to 82°C) |
| Dimensions | 9.5 × 8.75 |
| Weight | 8 lb |
Information About AFS-951-1
The AFS-951-1 belongs to the Cleveland Controls AFS-951 Series of air pressure sensing switches. It is designed for monitoring airflow and pressure conditions in combustion systems, furnaces, ventilation blowers, fume hoods, and air filtration equipment. The switch operates mechanically through a diaphragm and adjustable spring mechanism, allowing users to set the desired pressure activation point. Its weather-resistant steel enclosure features a hinged cover and gasketed construction for demanding installation environments.
Key Features:
-
Adjustable Pressure Setpoint: Provides a field-adjustable operating range from 0.05 to 12.0 inches water column for flexible pressure monitoring.
-
Differential Pressure Sensing: Monitors positive, negative, or differential air pressure using separate high- and low-pressure connections.
-
SPDT Switching Contacts: Features a single-pole double-throw snap-action switch with normally closed contacts before pressure activation.
-
NEMA 4 Enclosure: Includes a protective enclosure designed to resist dust, dirt, oil, and water exposure.
-
Industrial Electrical Rating: Supports switching loads up to 15 A non-inductive at 277 VAC, with specified pilot-duty ratings.
-
Dual Pressure Connections: Features two 1/4-inch NPT female pressure fittings for high- and low-pressure sampling.
-
Wide Operating Temperature: Designed to operate in ambient temperatures from -40°F to 180°F (-40°C to 82°C).
-
Industrial Safety Applications: Suitable for combustion draft monitoring, airflow proving, filter monitoring, and ventilation system protection.
The AFS-951-1 delivers adjustable pressure monitoring, dependable SPDT switching, and a rugged NEMA 4 enclosure for commercial and industrial air-handling applications.
Description
The Cleveland Controls AFS-951-1 is an adjustable differential air pressure sensing switch designed to monitor positive, negative, and differential air pressure in commercial and industrial ventilation systems. It features a field-adjustable setpoint range of 0.05 to 12.0 inches water column (in. w.c.) and a single-pole double-throw (SPDT) switch contact. Its NEMA 4-rated enclosure provides protection against dust, dirt, oil, and water.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Cleveland Controls |
| Manufacturer | UniControl Inc. |
| Category | HVAC & Building Automation |
| Part Number | AFS-951-1 |
| Subcategory | Differential Air Pressure Switches |
| Series | AFS-951 |
| Device Type | Adjustable Differential Air Pressure Switch |
| Setpoint Range | 0.05–12.0 in. w.c. |
| Switch Contact | SPDT, Normally Closed |
| Switch Differential | 0.02–0.8 in. w.c. Approx. |
| Maximum Pressure | 0.5 PSI |
| Electrical Rating | 15 A Non-Inductive at 277 VAC |
| Pilot Duty Rating | 300 VA at 277 VAC |
| Pressure Connections | Two 1/4-Inch NPT Female Fittings |
| Electrical Connection | Numbered Terminal Block |
| Conduit Opening | 7/8-Inch Opening for 1/2-Inch Conduit |
| Enclosure Material | 14-Gauge Enameled Steel |
| Protection Rating | NEMA 4 |
| Operating Temperature | -40°F to 180°F (-40°C to 82°C) |
| Dimensions | 9.5 × 8.75 |
| Weight | 8 lb |
Information About AFS-951-1
The AFS-951-1 belongs to the Cleveland Controls AFS-951 Series of air pressure sensing switches. It is designed for monitoring airflow and pressure conditions in combustion systems, furnaces, ventilation blowers, fume hoods, and air filtration equipment. The switch operates mechanically through a diaphragm and adjustable spring mechanism, allowing users to set the desired pressure activation point. Its weather-resistant steel enclosure features a hinged cover and gasketed construction for demanding installation environments.
Key Features:
-
Adjustable Pressure Setpoint: Provides a field-adjustable operating range from 0.05 to 12.0 inches water column for flexible pressure monitoring.
-
Differential Pressure Sensing: Monitors positive, negative, or differential air pressure using separate high- and low-pressure connections.
-
SPDT Switching Contacts: Features a single-pole double-throw snap-action switch with normally closed contacts before pressure activation.
-
NEMA 4 Enclosure: Includes a protective enclosure designed to resist dust, dirt, oil, and water exposure.
-
Industrial Electrical Rating: Supports switching loads up to 15 A non-inductive at 277 VAC, with specified pilot-duty ratings.
-
Dual Pressure Connections: Features two 1/4-inch NPT female pressure fittings for high- and low-pressure sampling.
-
Wide Operating Temperature: Designed to operate in ambient temperatures from -40°F to 180°F (-40°C to 82°C).
-
Industrial Safety Applications: Suitable for combustion draft monitoring, airflow proving, filter monitoring, and ventilation system protection.
The AFS-951-1 delivers adjustable pressure monitoring, dependable SPDT switching, and a rugged NEMA 4 enclosure for commercial and industrial air-handling applications.