Control Techniques 82100000012500 SM-I/O Lite Analog and Digital Expansion Module for Compatible Drives
- Regular price
- $399.00
- Sale price
- $399.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: 82100000012500
Description
The Control Techniques 82100000012500 is an SM-I/O Lite expansion module that adds analog signals, digital inputs, and relay control to compatible drives. It connects external sensors, reference signals, and machine controls to the drive’s configurable parameter system.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Control Techniques |
| Category | Drives and Accessories |
| Part Number | 82100000012500 |
| Subcategory | I/O Expansion Modules |
| Module Designation | SM-I/O Lite |
| Product Family | Solutions Modules |
| Analog Inputs | 1 |
| Analog Input Modes | ±10 V bipolar; 4–20 mA or 0–20 mA |
| Analog Outputs | 1 |
| Analog Output Modes | 0–10 V; 4–20 mA or 0–20 mA |
| Digital Inputs | 3 |
| Relay Outputs | 1 |
| Relay Contact Ratings | 2 A at 240 V AC; 4 A at 30 V DC |
| Reference Input | Encoder or frequency reference functions, host-dependent |
| Encoder Reference Limitation | Not functional with Unidrive SP; intended for basic speed following on supported hosts |
| Signal Connector | 12-way pluggable terminal connector |
| Relay Connector | 3-way pluggable screw-terminal connector |
| Identification Color | Dark yellow |
| Weight | 1 lb |
Information About 82100000012500
The 82100000012500 is part of the Control Techniques Solutions Module range. It installs in a compatible drive option slot and uses removable terminal connectors for external wiring. Its analog channels support voltage or current signals, allowing connection to different industrial control devices. Reference encoder functionality depends on the host drive and is unavailable when the module is used with Unidrive SP.
Key Features:
- Configurable Analog Input: Provides one input accepting ±10 V, 4–20 mA, or 0–20 mA signals.
- Analog Monitoring Output: Includes one output configurable for 0–10 V, 4–20 mA, or 0–20 mA.
- Digital Input Expansion: Adds three digital inputs for external machine commands.
- Relay Output: Provides one relay contact rated at 2 A at 240 V AC or 4 A at 30 V DC.
- Reference Encoder Interface: Supports basic speed-following references on compatible hosts; unavailable on Unidrive SP.
- Removable Connections: Uses separate pluggable connectors for relay and signal wiring.
- Drive Parameter Integration: Allows supported signals to be configured and monitored through the host drive.
The 82100000012500 delivers the reliability and precision required for expanded signal interfacing in compatible industrial drive systems.
Description
The Control Techniques 82100000012500 is an SM-I/O Lite expansion module that adds analog signals, digital inputs, and relay control to compatible drives. It connects external sensors, reference signals, and machine controls to the drive’s configurable parameter system.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Control Techniques |
| Category | Drives and Accessories |
| Part Number | 82100000012500 |
| Subcategory | I/O Expansion Modules |
| Module Designation | SM-I/O Lite |
| Product Family | Solutions Modules |
| Analog Inputs | 1 |
| Analog Input Modes | ±10 V bipolar; 4–20 mA or 0–20 mA |
| Analog Outputs | 1 |
| Analog Output Modes | 0–10 V; 4–20 mA or 0–20 mA |
| Digital Inputs | 3 |
| Relay Outputs | 1 |
| Relay Contact Ratings | 2 A at 240 V AC; 4 A at 30 V DC |
| Reference Input | Encoder or frequency reference functions, host-dependent |
| Encoder Reference Limitation | Not functional with Unidrive SP; intended for basic speed following on supported hosts |
| Signal Connector | 12-way pluggable terminal connector |
| Relay Connector | 3-way pluggable screw-terminal connector |
| Identification Color | Dark yellow |
| Weight | 1 lb |
Information About 82100000012500
The 82100000012500 is part of the Control Techniques Solutions Module range. It installs in a compatible drive option slot and uses removable terminal connectors for external wiring. Its analog channels support voltage or current signals, allowing connection to different industrial control devices. Reference encoder functionality depends on the host drive and is unavailable when the module is used with Unidrive SP.
Key Features:
- Configurable Analog Input: Provides one input accepting ±10 V, 4–20 mA, or 0–20 mA signals.
- Analog Monitoring Output: Includes one output configurable for 0–10 V, 4–20 mA, or 0–20 mA.
- Digital Input Expansion: Adds three digital inputs for external machine commands.
- Relay Output: Provides one relay contact rated at 2 A at 240 V AC or 4 A at 30 V DC.
- Reference Encoder Interface: Supports basic speed-following references on compatible hosts; unavailable on Unidrive SP.
- Removable Connections: Uses separate pluggable connectors for relay and signal wiring.
- Drive Parameter Integration: Allows supported signals to be configured and monitored through the host drive.
The 82100000012500 delivers the reliability and precision required for expanded signal interfacing in compatible industrial drive systems.