D0-06DR | Automation Direct DirectLOGIC DL06 PLC, 120-240 VAC required, serial ports, Discrete Input: 20-point, DC, Discrete Output: 16-point, relay
- Regular price
- $622.00
- Sale price
- $622.00
- Regular price
-
Do you need more quantity?
Product Description P/N: D0-06DR
Description
14.8k words total (7679 words ladder - flash, 7488 words V-memory), RLL/RLLPLUS programming (DirectSOFT32 Version 4.0 or higher), two built-in RS-232C communication ports. Secondary communications port supports RS-232C/RS-422/RS-485, DirectNET Master/Slave, MODBUS RTU, Master/Slave, and ASCII In/Out. Inputs: 20 DC inputs, 12-24 VDC current sinking/sourcing, 5 isolated commons (4 inputs per common). First 4 inputs are configurable in one of several high-speed I/O features such as 7KHz counter input, pulse catch input, or interrupt input. Outputs: 16 relay outputs, 6-27 VDC, 6-240 VAC, 2A/point max., 4 isolated commons (4 points per common). Four option slots available for I/O or communication modules.
Technical Specifications
Brand | Automation Direct |
Communication Port | SERIAL PORT |
Part Number | D0-06DR |
Inputs | 20 POINT |
Output Type | DISCRETE / RELAY |
Outputs | 16 POINT |
Product Family | DIRECTLOGIC DL06 |
Product Type | PLC UNIT |
Voltage | 120-240 VAC |
Information About D0-06DR
Operating modes are available on DL05 Micro PLC Model D0-06DR that enable programming functions. The modes are available through a handheld device.
The power requirement for external input must be between 100 and 240 VAC/50-60 Hz, 40 W maximum. The range for the input voltage is between 10.8 and 26.4 VDC.
The operating voltage is rated as between 12 and 24 VDC. Five banks of four is the arrangement of the inputs. One isolated common terminal is provided for each bank. Each bank can be configured as sinking or sourcing inputs.
The relay output voltage range is 5-264 VAC (47 -63 Hz), 5-30 VDC and the operating voltage range is 6-240 VAC (47-63 Hz), 6-27 VDC. Outputs are organized into four banks of four normally-open relay contacts. Each bank has a common terminal.
The DL05 Micro PLC Model D0-06DR has one RS–232C communication port and one multi-function RS232C/RS422/RS485 port. 20 DC inputs and 16 relay contact outputs are provided on the D0-06DR.
You can connect the D0-06DR to a handheld device that contains DirectSOFT 5. Port 1 on the D0-06DR is a 6-pin modular connector. Port 2 is a 15-pin HD-sub connector.
The DL05 Micro PLC D0-06DR offers V-memory data storage and diagnostics.
Manufacturer information
Automation Direct is a well-established supplier of industrial automation and control products. Founded in 1994, the company offers a wide range of cost-effective, user-friendly solutions, including PLCs, HMIs, sensors, and more, catering to diverse automation needs globally.
IQElectro 2 Year Warranty
IQElectro offers a 2-Year Warranty on all our products. This complimentary two-year warranty ensures that every purchase from IQElectro is a secure investment in the future of your company.Warranty Terms and Conditions
Description
14.8k words total (7679 words ladder - flash, 7488 words V-memory), RLL/RLLPLUS programming (DirectSOFT32 Version 4.0 or higher), two built-in RS-232C communication ports. Secondary communications port supports RS-232C/RS-422/RS-485, DirectNET Master/Slave, MODBUS RTU, Master/Slave, and ASCII In/Out. Inputs: 20 DC inputs, 12-24 VDC current sinking/sourcing, 5 isolated commons (4 inputs per common). First 4 inputs are configurable in one of several high-speed I/O features such as 7KHz counter input, pulse catch input, or interrupt input. Outputs: 16 relay outputs, 6-27 VDC, 6-240 VAC, 2A/point max., 4 isolated commons (4 points per common). Four option slots available for I/O or communication modules.
Technical Specifications
Brand | Automation Direct |
Communication Port | SERIAL PORT |
Part Number | D0-06DR |
Inputs | 20 POINT |
Output Type | DISCRETE / RELAY |
Outputs | 16 POINT |
Product Family | DIRECTLOGIC DL06 |
Product Type | PLC UNIT |
Voltage | 120-240 VAC |
Information About D0-06DR
Operating modes are available on DL05 Micro PLC Model D0-06DR that enable programming functions. The modes are available through a handheld device.
The power requirement for external input must be between 100 and 240 VAC/50-60 Hz, 40 W maximum. The range for the input voltage is between 10.8 and 26.4 VDC.
The operating voltage is rated as between 12 and 24 VDC. Five banks of four is the arrangement of the inputs. One isolated common terminal is provided for each bank. Each bank can be configured as sinking or sourcing inputs.
The relay output voltage range is 5-264 VAC (47 -63 Hz), 5-30 VDC and the operating voltage range is 6-240 VAC (47-63 Hz), 6-27 VDC. Outputs are organized into four banks of four normally-open relay contacts. Each bank has a common terminal.
The DL05 Micro PLC Model D0-06DR has one RS–232C communication port and one multi-function RS232C/RS422/RS485 port. 20 DC inputs and 16 relay contact outputs are provided on the D0-06DR.
You can connect the D0-06DR to a handheld device that contains DirectSOFT 5. Port 1 on the D0-06DR is a 6-pin modular connector. Port 2 is a 15-pin HD-sub connector.
The DL05 Micro PLC D0-06DR offers V-memory data storage and diagnostics.
Manufacturer information