Product Description P/N: DACT-UD2
Description
The Fire-Lite DACT-UD2 is a digital alarm communicator transmitter designed for integration with compatible fire alarm control panels. It provides reliable communication of fire system status to UL-listed central station receivers via public switched telephone networks. The DACT-UD2 enhances system monitoring by transmitting alarm, trouble, and supervisory conditions.
Technical Specifications
Condition | New/Never Used Surplus |
Brand | Fire-Lite Alarms by Honeywell |
Category | Fire Safety |
Part Number | DACT-UD2 |
Subcategory | Digital Communicator Module |
Communication Method | Public switched telephone network (PSTN) |
Supported Reporting | Up to 636 points or 99 zones |
Telephone Lines | Dual supervised |
Mounting | Directly mounts to FACP main circuit boards |
Test Signal Options | 12- or 24-hour alternating phone line test |
Supervised Functions | Phone line loss, communication failure, NAC faults, SLC faults |
Trouble Annunciation | Displayed at fire alarm control panel |
Protection | Extensive transient protection |
Power Source | Draws from host control panel |
Application | Fire alarm central station communication |
Listings & Approvals | UL listed, Central Station Receiver compatible |
Weight | Approx. 1 lb |
Information About DACT-UD2
The DACT-UD2 is a plug-in communicator module that mounts directly to the main circuit boards of Fire-Lite fire alarm control panels. It supports reporting of up to 636 points or 99 zones, ensuring detailed event communication. With dual supervised telephone lines, extensive transient protection, and compatibility with UL-listed receivers, the unit is suitable for high-reliability life safety applications. Designed for ease of integration, the DACT-UD2 ensures continuity of monitoring even in complex fire alarm systems.
Key Features
- Dual Supervised Lines: Maintains communication integrity using two monitored phone lines.
- High Capacity Reporting: Supports up to 636 points or 99 zones for detailed event reporting.
- Transient Protection: Built-in safeguards protect against electrical surges and interference.
- System Status Communication: Reports alarm, trouble, supervisory, AC loss, low battery, earth fault, and other conditions.
- Automated Test Signals: Sends alternating 12- or 24-hour test signals to verify communication reliability.
- Panel Annunciation: Displays communication and DACT-specific troubles at the fire alarm control panel.
- Compact Installation: Mounts directly inside compatible control panels for a secure fit.
- Fail-Safe Communication: Designed to detect and signal total communication failure with central stations.
The DACT-UD2 delivers the reliability and precision required for continuous fire alarm system monitoring and central station reporting.
Description
The Fire-Lite DACT-UD2 is a digital alarm communicator transmitter designed for integration with compatible fire alarm control panels. It provides reliable communication of fire system status to UL-listed central station receivers via public switched telephone networks. The DACT-UD2 enhances system monitoring by transmitting alarm, trouble, and supervisory conditions.
Technical Specifications
Condition | New/Never Used Surplus |
Brand | Fire-Lite Alarms by Honeywell |
Category | Fire Safety |
Part Number | DACT-UD2 |
Subcategory | Digital Communicator Module |
Communication Method | Public switched telephone network (PSTN) |
Supported Reporting | Up to 636 points or 99 zones |
Telephone Lines | Dual supervised |
Mounting | Directly mounts to FACP main circuit boards |
Test Signal Options | 12- or 24-hour alternating phone line test |
Supervised Functions | Phone line loss, communication failure, NAC faults, SLC faults |
Trouble Annunciation | Displayed at fire alarm control panel |
Protection | Extensive transient protection |
Power Source | Draws from host control panel |
Application | Fire alarm central station communication |
Listings & Approvals | UL listed, Central Station Receiver compatible |
Weight | Approx. 1 lb |
Information About DACT-UD2
The DACT-UD2 is a plug-in communicator module that mounts directly to the main circuit boards of Fire-Lite fire alarm control panels. It supports reporting of up to 636 points or 99 zones, ensuring detailed event communication. With dual supervised telephone lines, extensive transient protection, and compatibility with UL-listed receivers, the unit is suitable for high-reliability life safety applications. Designed for ease of integration, the DACT-UD2 ensures continuity of monitoring even in complex fire alarm systems.
Key Features
- Dual Supervised Lines: Maintains communication integrity using two monitored phone lines.
- High Capacity Reporting: Supports up to 636 points or 99 zones for detailed event reporting.
- Transient Protection: Built-in safeguards protect against electrical surges and interference.
- System Status Communication: Reports alarm, trouble, supervisory, AC loss, low battery, earth fault, and other conditions.
- Automated Test Signals: Sends alternating 12- or 24-hour test signals to verify communication reliability.
- Panel Annunciation: Displays communication and DACT-specific troubles at the fire alarm control panel.
- Compact Installation: Mounts directly inside compatible control panels for a secure fit.
- Fail-Safe Communication: Designed to detect and signal total communication failure with central stations.
The DACT-UD2 delivers the reliability and precision required for continuous fire alarm system monitoring and central station reporting.